文献速递眼底病与葡萄膜炎

年龄相关性黄斑变性继发地图样萎缩区域内的光敏感度

Light Sensitivity Within Areas of Geographic Atrophy Secondary to Age-Related Macular Degeneration.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

研究采用眼底控制微视野计检测地图样萎缩(GA)内距萎缩边界-0.645°等距线的残余光敏感度,30眼1380个阈值检测显示实测敏感度显著高于绝对暗点预期值,外层核层存在对暗视红光差异有显著影响,提示GA内交界区可能存在残余视锥细胞功能。

要点

  • GA内交界区实测敏感度显著高于绝对暗点预期值,明适应+6.92±0.86 dB、暗适应蓝光+2.57±0.56 dB、暗适应红光+4.93±0.74 dB。
  • 明适应和暗适应红光检测中,残余外层核层对实测与预期差异有显著影响(P<0.001)。
  • 注视稳定性及其他可靠性指标对该差异无影响。

核心结论

  • GA内交界区实测敏感度可能不能仅用患者特异性假阳性反应率或其他可靠性指标解释。
  • 外层视网膜结构对实测敏感度的显著影响可能提示GA内交界区存在残余视锥细胞功能。

研究设计与样本

  • 研究为前瞻性自然病史研究Directional Spread in Geographic Atrophy(NCT02051998)的一部分,纳入36例患者共30眼,年龄75.55±7.93岁,女性19例。
  • 采用眼底控制微视野计检测明适应和暗适应蓝光及红光敏感度(Goldmann III),测试点置于GA内距萎缩边界-0.645°的等距线上,共1380个阈值检测。
  • 通过视盘阈上刺激(Heijl-Krakau法)测定假阳性反应率,并计算绝对暗点假设下的预期敏感度;同时用频域光学相干断层扫描确定每个测试点处最外层可见视网膜层。

主要发现

  • 实测敏感度显著高于绝对暗点预期值(P<0.01),明适应平均差值+6.92±0.86 dB,暗适应蓝光+2.57±0.56 dB,暗适应红光+4.93±0.74 dB。
  • 明适应检测和暗适应红光检测中,残余外层核层存在对实测与预期差异有显著影响(P<0.001)。
  • 注视稳定性或其他任何可靠性指标对该差异均无影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate residual sensitivity within geographic atrophy (GA) secondary to age-related macular degeneration. METHODS: Mesopic and dark-adapted (DA) cyan and red light sensitivity (Goldmann III) were investigated using fundus-controlled perimetry (microperimetry). Test points were placed within GA along an "iso-hull" with a distance of -0.645° to the atrophy boundary. The false-positive response rate was determined with suprathreshold stimuli to the optic disc (Heijl-Krakau method) and used to compute the expected sensitivity measurements for the assumption of absolute scotomata. The outermost visible retinal layer on spectral-domain optical coherence tomography at the location of each test point was determined. RESULTS: Thirty eyes of 36 patients (75.55 ± 7.93 years; 19 female) from the prospective natural history study Directional Spread in Geographic Atrophy (NCT02051998), with a total of 1380 threshold determinations were analyzed. The measured sensitivities were significantly (P < 0.01) higher than the expected values for absolute scotomata (mean ± standard error of +6.92 ± 0.86 dB for mesopic, +2.57 ± 0.56 dB for DA cyan, and +4.93 ± 0.74 dB for DA red testing). For mesopic testing and DA red testing, the presence of a residual outer nuclear layer had a significant effect on this discrepancy (P < 0.001). There was no effect of fixation stability or any other reliability index on this discrepancy. CONCLUSIONS: Measured sensitivities within the inner junctional zone of GA may not be purely explained by patient-specific false-positive response rates or other reliability indices. The marked influence of the outer retinal configuration on measured sensitivity may be indicative of residual cone function within GA at the inner junctional zone.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Pfau M, von der Emde L, Dysli C, et al. Light Sensitivity Within Areas of Geographic Atrophy Secondary to Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2019. PMID: 31560765. doi:10.1167/iovs.19-27178

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。