文献速递眼底病与葡萄膜炎

糖尿病视网膜病变超广角荧光素血管造影中视网膜分形维数与无灌注的关系

Relationship Between Retinal Fractal Dimension and Nonperfusion in Diabetic Retinopathy on Ultrawide-Field Fluorescein Angiography.
PubMed 文献 · Am J Ophthalmol · 2019-08-29

横断面研究纳入80只糖尿病视网膜病变眼,在超广角荧光素血管造影图像上计算视网膜血管分形维数并与无灌注面积相关分析。全视网膜分形维数与整体无灌注面积呈负相关(R=-0.44,P<.001),周边部分形维数较正常眼显著减小(P<.001)。分形维数可自动计算且无需矫正周边畸变,可能成为无灌注精确定量不可行时的替代生物标志物。

要点

  • 糖尿病视网膜病变眼远周边部分形维数较正常对照眼显著减小(P<.001)。
  • 全视网膜分形维数与整体无灌注面积呈负相关(R=-0.44,P<.001)。
  • 后极部、中周边部和远周边部三个同心区域分形维数均与无灌注面积负相关。

核心结论

  • 糖尿病视网膜病变眼超广角荧光素血管造影的周边部分形维数较正常眼减小,且与视网膜无灌注严重程度相关。
  • 分形维数可自动计算且无需矫正周边畸变,可能成为无灌注精确定量不可行时有用的替代生物标志物。

研究设计与样本

  • 横断面研究,纳入DAVE研究(NCT01552408)和RECOVERY研究(NCT02863354)中80只糖尿病视网膜病变眼的基线Optos 200Tx超广角荧光素血管造影图像,在Doheny图像阅读中心进行立体投影。
  • 通过利用血管细长特征从早期荧光素血管造影帧中提取视网膜血管,骨架化后采用盒计数法计算分形维数。
  • 无灌注面积由2名独立、阅读中心认证且对研究分组设盲的评估者按标准化方案勾画,并以平方毫米计算。

主要发现

  • 糖尿病视网膜病变眼全视网膜分形维数与正常对照眼相比无差异,但远周边部分形维数在糖尿病视网膜病变眼显著更小(P<.001)。
  • 全视网膜分形维数与整体无灌注面积呈负相关(R=-0.44;P<.001)。
  • 分形维数与无灌注面积的负相关在后极部(R=-0.31,P=.016)、中周边部(R=-0.35,P=.007)和远周边部(R=-0.31,P=.015)三个同心视网膜区域内均存在。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To correlate fractal dimension (FD) of the retinal vasculature with the extent of retinal nonperfusion area in diabetic retinopathy (DR) on ultrawide-field fluorescein angiography (FA). DESIGN: Cross-sectional study. METHODS: Baseline Optos 200Tx ultrawide-field FA images of 80 eyes with DR from the DAVE (NCT01552408) and RECOVERY (NCT02863354) studies were stereographically projected at the Doheny Image Reading Center. The retinal vasculature was extracted from an early-phase FA frame by exploiting the elongated nature of the vessels and then skeletonized for calculation of FD using a box-counting method. The nonperfusion area was delineated by 2 independent, reading center-certified graders who were masked to the study groups and who were using a standardized protocol and then computed in millimeters squared. RESULTS: While no difference in FD was observed for the entire retina in DR compared with normal control subjects, a significantly smaller FD was found in the far-periphery of the DR eyes (P < .001). FD for the entire retina was negatively associated with global nonperfusion area (R = -0.44; P < .001), and this relationship was also present within the 3 concentric retinal zones (posterior: R = -0.31, P = .016; midperiphery: R = -0.35, P = .007; and far periphery: R = -0.31, P = .015). CONCLUSIONS: Peripheral FD on ultrawide-field FA is reduced in DR eyes compared with normal eyes and is correlated with severity of retinal nonperfusion. FD can be calculated automatically without the need for correction of peripheral distortion, and therefore it may prove to be a useful surrogate biomarker when precise quantification of nonperfusion is not feasible.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Fan W, Nittala MG, Fleming A, et al. Relationship Between Retinal Fractal Dimension and Nonperfusion in Diabetic Retinopathy on Ultrawide-Field Fluorescein Angiography. Am J Ophthalmol. 2019. PMID: 31472160. doi:10.1016/j.ajo.2019.08.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。