Fuchs内皮性角膜营养不良中角膜水肿的日间变化
前瞻性队列研究测量临床晚期Fuchs角膜营养不良眼与健康角膜在一天中不同时间点的角膜厚度和后表面形态。觉醒后4小时内Fuchs组角膜厚度下降,后表面Q值和曲率半径减小;4小时后变化不大。结论认为晚期Fuchs患者睁眼后即刻测量关键角膜参数不可靠。
要点
- 觉醒即刻Fuchs组平均角膜厚度663 μm(IQR 625-707),对照组557 μm(IQR 527-601)。
- Fuchs组觉醒后4小时内角膜厚度预计下降31-58 μm(95%预测区间)。
- 4小时后Fuchs眼角膜厚度变化与正常眼相比不太可能更大。
核心结论
- 临床晚期Fuchs角膜营养不良因水化控制受损,睁眼后即刻测量关键角膜参数不可靠。
- 睁眼后最初数小时之后,Fuchs眼角膜厚度测量值与正常眼相比不太可能有更大变化。
研究设计与样本
- 前瞻性队列研究,纳入接受内皮角膜移植术的临床晚期Fuchs角膜营养不良眼(n=44)和健康角膜对照眼(n=11)。
- 在术前一天中午和傍晚(假定稳态)评估,经控制性过夜眼罩遮盖标准化眼睑闭合后,于手术当日早晨在医院睁眼后即刻评估。
- 使用Scheimpflug成像测量角膜厚度和后表面形态。
主要发现
- 觉醒即刻Fuchs组平均角膜厚度663 μm(IQR 625-707),对照组557 μm(IQR 527-601)。
- 对照眼角膜随时间无系统性变化。
- Fuchs眼觉醒后角膜厚度下降,95%患者觉醒后最初4小时内角膜厚度下降预计在31 μm至58 μm之间(95%预测区间)。
- 觉醒后最初4小时内后表面Q值平均下降0.15(95%CI 0.07-0.23),后表面曲率半径减小0.20 mm(95%CI 0.14-0.27),表明水肿消退使中央后角膜变陡。
- 觉醒后4小时之后,Fuchs眼角膜不再有显著变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The extent of diurnal variation in corneal edema in Fuchs dystrophy is unknown. We measured corneal thickness and posterior profile over the course of the day using Scheimpflug imaging. DESIGN: Prospective cohort study. METHODS: Participants with clinically advanced Fuchs dystrophy eyes undergoing endothelial keratoplasty and participants with healthy corneas were assessed around noon the day before surgery and late afternoon, in presumed steady state. After controlled overnight patching to standardize eyelid closure, participants were assessed immediately upon eye opening in hospital the morning of surgery. RESULTS: Directly upon awakening, patients had mean corneal thickness of 663 μm (interquartile range [IQR], 625-707) in Fuchs dystrophy (n = 44) and controls (n = 11) had thickness of 557 μm (IQR, 527-601). In control corneas, there were no systematic changes with time. In Fuchs dystrophy eyes, corneal thickness decreased after awakening. Ninety-five percent of patients can be expected to have a decrease in corneal thickness over the first 4 hours after awakening between 31 μm and 58 μm (95% prediction interval). Posterior Q decreased on average by 0.15 (95% confidence interval [CI], 0.07-0.23) and posterior radius of curvature decreased by 0.20 mm (95% CI, 0.14-0.27) over the first 4 hours, indicating that edema resolution steepened the central posterior cornea. Beyond 4 hours after awakening, corneas no longer changed considerably in Fuchs dystrophy. CONCLUSION: Impaired hydration control in clinically advanced Fuchs dystrophy makes measurements of key corneal parameters unreliable directly after eye opening. Beyond the first hours after eye opening, corneal thickness measurements are unlikely to vary more in Fuchs dystrophy eyes than in normal eyes.
引用
- Fritz M, Grewing V, Maier P, et al. Diurnal Variation in Corneal Edema in Fuchs Endothelial Corneal Dystrophy. Am J Ophthalmol. 2019. PMID: 31415734. doi:10.1016/j.ajo.2019.08.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。