文献速递青光眼

在正常受试者、青光眼疑似者及青光眼患者中临床评估瑞典交互式阈值算法-快速版与标准版的对比

Clinical Evaluation of Swedish Interactive Thresholding Algorithm-Faster Compared With Swedish Interactive Thresholding Algorithm-Standard in Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2019-08-27

前瞻性横断面研究纳入364例(正常77例、青光眼疑似178例、青光眼109例)单眼,比较SS与SFR两种视野算法。SFR不可靠结果率29.3%高于SS的7.7%(P<.0001),主要因高假阳性率和种子点错误;校正可靠性后SFR可节省时间。SFR灵敏度更高(青光眼患者平均高0.5 dB),在视野缺损<19 dB时更明显。

要点

  • SFR不可靠结果率为29.3%,高于SS的7.7%(P<.0001)。
  • SFR主要误差来源为高假阳性率和种子点错误。
  • 校正可靠性后SFR可显著节省检查时间,但两种算法结果不能直接互换。

核心结论

  • 校正不同的检查可靠性率后,与SS相比,SFR可显著节省时间。
  • 临床医生应认识到假阳性率和种子点错误是SFR的常见误差来源。
  • 两种算法的结果不能直接互换,尤其在视野缺损<19 dB时。

研究设计与样本

  • 前瞻性、横断面研究,纳入364例受试者(正常77例、青光眼疑似178例、青光眼109例),每例随机选一只眼在同一机构使用Humphrey视野分析仪分别进行SS和SFR检查。

主要发现

  • SFR的不可靠结果率为29.3%,高于SS的7.7%(P<.0001),主要由于高假阳性率和种子点错误。
  • 模型化检查时间显示,SFR可在更短时间内获得更多可靠结果。
  • SFR导致更高的灵敏度值(青光眼患者平均高0.5 dB),在视野缺损<19 dB条件下更高。
  • 聚类分析显示两种算法间灵敏度差异无系统性模式。

临床怎么用

  • 临床医生应认识到假阳性率和种子点错误是SFR的常见误差来源。
  • 两种算法的结果不能直接互换,尤其在视野缺损<19 dB时。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the visual fields results obtained using the Swedish interactive thresholding algorithm-Standard (SS) and the Swedish interactive thresholding algorithm-Faster (SFR) in normal subjects, glaucoma suspects, and patients with glaucoma and to quantify potential time-saving benefits of the SFR algorithm. DESIGN: Prospective, cross-sectional study. METHODS: One randomly selected eye from 364 patients (77 normal subjects, 178 glaucoma suspects, and 109 patients with glaucoma) seen in a single institution underwent testing using both SS and SFR on the Humphrey Field Analyzer. Cumulative test time using each algorithm was compared after accounting for different rates of test reliability. Pointwise and cluster analysis was performed to determine whether there were systematic differences between algorithms. RESULTS: Using SFR had a greater rate of unreliable results (29.3%) compared with SS (7.7%, P < .0001). This was mainly because of high false positive rates and seeding point errors. However, modeled test times showed that using SFR could obtain a greater number of reliable results within a shorter period of time. SFR resulted in higher sensitivity values (on average 0.5 dB for patients with glaucoma) that was greater under conditions of field loss (<19 dB). Cluster analysis showed no systematic patterns of sensitivity differences between algorithms. CONCLUSIONS: After accounting for different rates of test reliability, SFR can result in significant time savings compared with SS. Clinicians should be cognizant of false positive rates and seeding point errors as common sources of error for SFR. Results between algorithms are not directly interchangeable, especially if there is a visual field deficit <19 dB.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Phu J, Khuu SK, Agar A, et al. Clinical Evaluation of Swedish Interactive Thresholding Algorithm-Faster Compared With Swedish Interactive Thresholding Algorithm-Standard in Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma. Am J Ophthalmol. 2019. PMID: 31470001. doi:10.1016/j.ajo.2019.08.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。