低度与高度近视眼角膜生物力学比较——一项荟萃分析
该系统综述与荟萃分析纳入11项研究,比较低度与高度近视眼的角膜生物力学。低度近视眼的角膜滞后量(CH)和角膜阻力因子(CRF)显著更高,角膜补偿眼压(IOPcc)和Goldmann相关眼压(IOPg)显著更低;两组中央角膜厚度(CCT)无显著差异。作者认为低CH、低CRF及高IOPcc、高IOPg可能是高度近视的相关因素。
要点
- 低度近视眼CH较高度近视眼高0.73 mmHg(95%CI 0.53至0.93,P<.001)。
- 低度近视眼CRF较高度近视眼高0.20 mmHg(95%CI 0.04至0.37,P=.02)。
- 两组CCT差异无统计学显著(均值差-2.85 μm,95%CI -9.64至3.93,P=.41)。
核心结论
- 高度近视眼角膜生物力学与低度近视眼不同,低CH、低CRF及高IOPcc、高IOPg被认为是高度近视的相关因素。
- 作者指出需要未来研究探讨导致高度近视眼低CH和CRF值的潜在角膜结构差异。
研究设计与样本
- 系统综述与荟萃分析,检索PubMed、Medline、EMBASE、Web of Science及万方、中国知网等中文数据库,最终纳入11项研究。
- 主要结局为高度近视眼与低度近视眼的角膜滞后量(CH)、角膜阻力因子(CRF)、角膜补偿眼压(IOPcc)、Goldmann相关眼压(IOPg)和中央角膜厚度(CCT)。
主要发现
- 低度近视眼CH显著高于高度近视眼,均值差0.73 mmHg(95%CI 0.53至0.93,P<.001)。
- 低度近视眼CRF显著高于高度近视眼,均值差0.20 mmHg(95%CI 0.04至0.37,P=.02)。
- 低度近视眼IOPcc显著低于高度近视眼,均值差-2.53 mmHg(95%CI -3.24至-1.83,P<.01)。
- 低度近视眼IOPg显著低于高度近视眼,均值差-1.42 mmHg(95%CI -2.26至-0.58,P=.0009)。
- 两组CCT差异无统计学显著,均值差-2.85 μm(95%CI -9.64至3.93,P=.41)。
局限性
- 作者指出需要未来研究探讨导致高度近视眼低CH和CRF值的潜在角膜结构差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the corneal biomechanical difference between the low myopic eyes and high myopic eyes. DESIGN: Systematic review and meta-analysis. METHODS: Data sources, including PubMed, Medline, EMBASE, Web of Science, and Chinese databases including Wanfang and China National Knowledge Infrastructure, were searched to find the relevant studies. Primary outcomes were corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), Goldmann-correlated intraocular pressure (IOPg), and central corneal thickness (CCT) in high myopic eyes and low myopic eyes. RESULTS: Eleven studies were enrolled in this study. CH and CRF were significantly higher in the low myopic eyes. The mean difference of CH was 0.73 mm Hg, 95% confidence interval (CI) [0.53 to 0.93], P < .001. The mean difference of CRF was 0.20 mm Hg, 95% CI [0.04 to 0.37], P = .02. The IOPcc and IOPg were significantly lower in the low myopic eyes. The mean difference of IOPcc was -2.53 mm Hg, 95% CI [-3.24, -1.83], P < .01. The mean difference of IOPg was -1.42 mm Hg, 95% CI [-2.26, -0.58], P = .0009. There was no significant difference between the 2 groups on CCT; the mean difference was -2.85 μm, 95% CI [-9.64.3.93], P = .41. CONCLUSION: Corneal biomechanics are different in the high myopic eyes. Low CH and CRF and high IOPcc and IOPg are suggested to be associated factors for high myopia. Future studies are needed to investigate the underlying corneal structure difference that causes the low CH and CRF value in the high myopic eyes.
引用
- Wu W, Dou R, Wang Y, et al. Comparison of Corneal Biomechanics Between Low and High Myopic Eyes-A Meta-analysis. Am J Ophthalmol. 2019. PMID: 31374186. doi:10.1016/j.ajo.2019.07.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。