超广角眼底自发荧光成像检测退行性视网膜劈裂并发神经感觉层视网膜脱离
本回顾性病例系列纳入连续诊断视网膜劈裂(RS)并接受超广角眼底自发荧光成像的患者,按自发荧光模式分为有高自发荧光前缘组和无高自发荧光组,并用外周谱域光学相干断层扫描验证。结果显示高自发荧光区对应全层神经感觉层视网膜与视网膜色素上皮分离,超广角眼底自发荧光可可靠检测RS相关视网膜脱离,可能是有用的诊断成像方式。
要点
- 38只符合条件眼纳入,21/39(55%)眼RS区见高自发荧光(A组),17/38(45%)眼无高自发荧光(B组)。
- A组10/10眼(100%)高自发荧光区经谱域OCT证实全层神经感觉层视网膜与RPE分离。
- B组0/11眼(0%)视网膜-RS界面谱域OCT显示全层神经感觉层视网膜分离。
核心结论
- 高自发荧光表现提示存在神经感觉层视网膜脱离,RS相关视网膜脱离可在超广角眼底自发荧光上可靠检测,可能是有用的诊断成像方式。
研究设计与样本
- 回顾性病例系列纳入连续诊断RS并具有超广角眼底自发荧光图像的患者,按自发荧光模式分为有高自发荧光前缘组和无高自发荧光组,并行RS水平外周谱域OCT。
主要发现
- 38只符合条件眼纳入,21/39(55%)眼RS区见独特高自发荧光(A组),17/38(45%)眼无任何形式高自发荧光(B组)。
- A组10/10眼(100%)高自发荧光区谱域OCT证实全层神经感觉层视网膜与下方RPE分离。
- B组0/11眼(0%)视网膜-RS界面谱域OCT显示全层神经感觉层视网膜分离。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine whether neurosensory retinal detachment complicating degenerative retinoschisis (RS) can be reliably detected with ultra-widefield fundus autofluorescence evaluation. METHODS: Consecutive patients diagnosed with RS who had ultra-widefield fundus autofluorescence imaging were included in this retrospective case series. According to the fundus autofluorescence patterns, we divided the eyes into two groups: 1) eyes with RS and a hyperautofluorescent leading edge and 2) eyes with RS and without hyperautofluorescence. Peripheral spectral domain optical coherence tomography images at the level of RS were obtained. RESULTS: Thirty-eight eyes that met eligibility criteria were identified. Review of ultra-widefield fundus autofluorescence demonstrated 21/39 (55%) eyes with distinctive hyperautofluorescence over the area of RS (Group A) and 17/38 (45%) eyes without any form of hyperautofluorescence (Group B). Spectral domain optical coherence tomography images confirmed the presence of full-thickness neurosensory retina separation from the underlying retinal pigment epithelium in the areas of hyperautofluorescence in 10/10 eyes (100%) from Group A. None (0/11; 0%) of the eyes from Group B showed full-thickness neurosensory retina separation on the spectral domain optical coherence tomography imaging of the retina-RS interface. CONCLUSION: Hyperautofluorescent findings suggest the presence of a neurosensory retinal detachment. Retinal detachment associated with RS can be reliably detected on ultra-widefield fundus autofluorescence and may be a useful diagnostic imaging modality.
引用
- Francone A, Kothari N, Farajzadeh M, et al. DETECTION OF NEUROSENSORY RETINAL DETACHMENT COMPLICATING DEGENERATIVE RETINOSCHISIS BY ULTRA-WIDEFIELD FUNDUS AUTOFLUORESCENCE IMAGING. Retina. 2020. PMID: 31397744. doi:10.1097/IAE.0000000000002488
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。