白内障超声乳化联合Callisto Eye辅助弧形角膜切开术后角膜散光的初步观察
前瞻性干预性非随机对照研究,纳入108例角膜散光≥0.75 D白内障患者,试验组76眼行超声乳化联合Callisto Eye辅助弧形角膜切开术,对照组32眼仅行超声乳化。术后3个月试验组裸眼视力0.15±0.12优于对照组0.24±0.17(P<0.01),散光矫正量1.15±0.58 D,未出现角膜穿透等并发症。
要点
- 试验组术后3个月裸眼视力0.15±0.12,优于对照组0.24±0.17(t=-4.129,P<0.01)。
- 试验组散光矫正量1.15±0.58 D,矫正指数0.97±0.20,成功指数0.51±0.36。
- C组(≥1.75 D)轴向偏差最小8.07°±3.13°、平坦指数最高0.72±0.31,A组最差。
核心结论
- 超声乳化白内障吸除联合Callisto Eye辅助弧形角膜切开术对角膜散光矫正有较高准确度和可预测性,对提高术后裸眼视力有效,是较为有效和安全的手术方式。
研究设计与样本
- 前瞻性干预性非随机对照研究,连续收集2017年10月至2018年3月首都医科大学附属北京同仁医院北京同仁眼科中心南区拟行白内障摘除且角膜散光≥0.75 D的患者。
- 共纳入108例(108只眼),男性46例、女性62例,年龄(68±11)岁;试验组76例(76只眼),对照组32例(32只眼)。
- 试验组按术前角膜散光分A组(0.75~1.24 D,38眼)、B组(1.25~1.74 D,18眼)、C组(≥1.75 D,20眼),弧形切口深度和弧长分别为0.50 mm、50°;0.50 mm、70°;0.55 mm、80°。
- 对照组行单纯超声乳化白内障吸除术,观察术中、术后并发症及术后3个月角膜散光度数和裸眼视力,采用独立样本t检验等分析。
主要发现
- 试验组术前、术后3个月角膜散光分别为(1.54±0.90)D和0.62(0.36~0.95)D,散光矫正量(1.15±0.58)D。
- 试验组矫正指数0.97±0.20、平坦指数0.61±0.31、轴向偏差9.55°±5.22°、成功指数0.51±0.36。
- 试验组中C组轴向偏差最小(8.07°±3.13°)、平坦指数最高(0.72±0.31),B组次之,A组轴向偏差10.27°±6.47°、平坦指数0.42±0.30。
- 术后3个月裸眼视力(最小分辨角对数视力)试验组0.15±0.12 vs 对照组0.24±0.17,两组差异有统计学意义(t=-4.129,P<0.01)。
- 入组患者未出现角膜穿透、切口愈合不良、角膜水肿、黄斑囊样水肿等术中、术后并发症。
关键数值与推荐
- 试验组与对照组年龄、性别分布、术前视力及散光度数差异均无统计学意义(均P>0.05)。
- 试验组A、B、C三个亚组弧形切口深度和弧长分别为0.50 mm、50°;0.50 mm、70°;0.55 mm、80°。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To research the change of cornea astigmatism after combined cataract phacoemulsification and Callisto Eye-assisted arcuate keratotomy and to assess the effectiveness and safety of this surgery for improving patients' uncorrected visual acuity. Methods: Prospective interventional non-randomized controlled study. Consecutive cataract patients with cornea astigmatism greater than 0.75 D were recruited at the southern part of Beijing Tongren Hospital, Capital Medical University and Beijing Tongren Eye Center, between October 2017 and March 2018, and were divided into the experimental group and the controlled group. In the experimental group the patients are further divided into three subgroups of A(0.75-1.24 D), B(1.25-1.74 D) and C(≥1.75 D) according to the degrees of their cornea astigmatism before surgery. The combined cataract phacoemulsification and Callisto Eye-assisted arcuate keratotomy were performed for the experimental group with the depth and length of the corneal arcuate incision differing in subgroups, while only cataract phacoemulsification was performed for the control group. The complications on and after the surgery were observed and the change of cornea astigmatism and uncorrected visual acuity in three months after surgery were recorded. Independent sample t test was used for statistical analysis. Results: A total of 108 patients (108 eyes) were enrolled, including 46 males and 62 females, the age was (68±11) years old.The experimental group included 76 eyes of 76 patients (subgroup A 38 eyes, subgroup B 18 eyes, subgroup C 20 eyes). The controlled group included 32 eyes of 32 patients. The preoperative cornea astigmatism and postoperative cornea astigmatism of the experimental group are (1.54±0.90) D and 0.62 (0.36-0.95) D. The change of cornea astigmatism of the experimental group is (1.15±0.58) D. The index of correction and flattening are 0.97±0.20 and 0.61±0.31 respectively, the error of axial deviation is 9.55°±5.22°. The index of success is 0.51±0.36. In the experimental group, subgroup C has the highest correction efficiency of corneal astigmatism (axial deviation error 8.07°±3.13°, flattening index 0.72±0.31) which is followed by subgroup B, and subgroup A ranked the last one (axial deviation error 10.27°±6.47°, flattening index 0.42±0.30).The uncorrected distance visual acuity (logarithm of the minimum angle of resolution) of the experimental group and the control group are significantly different (0.15±0.12 vs. 0.24±0.17, t=-4.129, P<0.01). None of the patients recruited have complications including poor wound healing and cornea penetration and cornea edema and cystoid macular edema on or after the surgery. Conclusions: Combined cataract phacoemulsification and Callisto Eye-assisted arcuate keratotomy are of favorable effect on improving the uncorrected visual acuity and have relatively good accuracy and predictability on the correction of cornea astigmatism. It is a safe surgery with considerable efficency. (Chin J Ophthalmol, 2019, 55: 502-508). 目的: 研究超声乳化白内障吸除联合导航下弧形角膜切开术后角膜散光变化以及提高术后裸眼视力的有效性和安全性。 方法: 前瞻性干预性非随机对照研究。连续收集首都医科大学附属北京同仁医院北京同仁眼科中心南区2017年10月至2018年3月拟行白内障摘除手术且角膜散光度数≥0.75 D的患者,分为试验组和对照组。试验组根据术前角膜散光度数分A组(0.75~1.24 D)、B组(1.25~1.74 D)、C组(≥1.75 D)3个亚组,行超声乳化白内障吸除联合Callisto Eye导航引导下的弧形角膜切开术,弧形切口的深度和弧长A、B、C 3个亚组分别为0.50 mm、50°;0.50 mm、70°;0.55 mm、80°。对照组行单纯超声乳化白内障吸除术。观察术中、术后并发症以及术后3个月患者角膜散光度数及裸眼视力等情况。统计学分析采用独立样本t检验等方法。 结果: 共纳入108例(108只眼)患者,男性46例,女性62例;就诊年龄(68±11)岁。试验组76例(76只眼)(A组38例、B组18例、C组20例),对照组32例(32只眼),试验组与对照组患者年龄、性别分布、术前视力及散光度数差异均无统计学意义(均P>0.05)。试验组术前、术后3个月的角膜散光度数分别为(1.54±0.90)D和0.62(0.36~0.95)D,散光矫正量为(1.15±0.58)D,矫正指数为0.97±0.20,平坦指数为0.61±0.31,轴向偏差为9.55°±5.22°,成功指数为0.51±0.36。试验组中C组散光矫正的准确性最高:轴线偏差最小(8.07°±3.13°),平坦指数最高(0.72±0.31);B组次之;最后是A组(轴线偏差10.27°±6.47°,平坦指数为0.42±0.30)。术后3个月试验组裸眼视力(最小分辨角对数视力)为0.15±0.12,对照组为0.24±0.17,两组间差异有统计学意义(t=-4.129,P<0.01)。入组患者中未出现角膜穿透、切口愈合不良、角膜水肿、黄斑囊样水肿等术中、术后并发症。 结论: 超声乳化白内障吸除联合导航引导下的弧形角膜切开术对角膜散光的矫正有较高的准确度和可预测性,对提高白内障摘除术后裸眼视力有效,是较为有效和安全的手术方式。(中华眼科杂志,2019,55:502-508).
引用
- Cao YX, Wang J. [Incipient observation of cornea astigmatism after combined cataract phacoemulsification and Callisto Eye-assisted arcuate keratotomy]. Zhonghua Yan Ke Za Zhi. 2019. PMID: 31288353. doi:10.3760/cma.j.issn.0412-4081.2019.07.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。