视网膜视锥-视杆营养不良患者中心凹视锥结构丢失先于视力下降
本研究对9例视锥-视杆营养不良(RCD)患者13眼和8名健康者13眼进行纵向自适应光学扫描激光检眼镜检查,间隔≥10个月(平均765天,范围311-1935天)。结果显示视锥间距与ETDRS字母数、logMAR及中心凹敏感度相关;随访期间RCD患者视锥间距Z评分平均增加+0.97(95%CI 0.57至1.4),而视力各指标无显著变化。
要点
- RCD患者随访期间视锥间距Z评分平均增加+0.97(95%CI 0.57至1.4),健康眼无此变化。
- 随访期间RCD患者视力各指标均无显著变化。
- 视锥间距Z评分可能比视力更敏感地反映RCD患者中心凹视锥丢失。
核心结论
- 在RCD患者中,随访期间视锥间距增加而视力无显著变化,视锥间距Z评分可能比视力更敏感地反映中心凹视锥丢失。
研究设计与样本
- 纵向研究纳入9例RCD患者13眼和8名健康者13眼,用自适应光学扫描激光检眼镜获取视网膜高分辨率图像,两次检查间隔≥10个月(平均765天,范围311-1935天)。
主要发现
- 视锥间距与ETDRS字母数相关(ρ=-0.47,95%CI -0.67至-0.24)。
- 视锥间距与logMAR相关(ρ=0.46,95%CI 0.24至0.66)。
- 视锥间距与中心凹敏感度相关(ρ=-0.30,95%CI -0.52至-0.018)。
- RCD患者随访期间平均视锥间距Z评分增加+0.97(95%CI 0.57至1.4),健康眼无此变化。
- 随访期间RCD患者视力各指标均无显著变化。
关键数值与推荐
- 视锥间距Z评分测量尽可能接近首选视网膜 locus(平均<0.25°)。
- 视力评估采用ETDRS视力表字母数和logMAR。
临床怎么用
- 原文结论认为视锥间距Z评分可能比视力更敏感地反映RCD患者中心凹视锥丢失,未据此给出具体临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the relationship between cone spacing and visual acuity in eyes with rod-cone degeneration (RCD) followed longitudinally. METHODS: High-resolution images of the retina were obtained using adaptive optics scanning laser ophthalmoscopy from 13 eyes of nine RCD patients and 13 eyes of eight healthy subjects at two sessions separated by 10 or more months (mean 765 days, range 311-1935 days). Cone spacing Z-score measured as close as possible (average <0.25°) to the preferred retinal locus was compared with visual acuity (letters read on the Early Treatment of Diabetic Retinopathy Study [ETDRS] chart and logMAR) and foveal sensitivity. RESULTS: Cone spacing was significantly correlated with ETDRS letters read (ρ = -0.47, 95%CI -0.67 to -0.24), logMAR (ρ = 0.46, 95%CI 0.24 to 0.66), and foveal sensitivity (ρ = -0.30, 95%CI -0.52 to -0.018). There was a small but significant increase in mean cone spacing Z-score during follow-up of +0.97 (95%CI 0.57 to 1.4) in RCD patients, but not in healthy eyes, and there was no significant change in any measure of visual acuity. CONCLUSIONS: Cone spacing was correlated with visual acuity and foveal sensitivity. In RCD patients, cone spacing increased during follow-up, while visual acuity did not change significantly. Cone spacing Z-score may be a more sensitive measure of cone loss at the fovea than visual acuity in patients with RCD.
引用
- Bensinger E, Rinella N, Saud A, et al. Loss of Foveal Cone Structure Precedes Loss of Visual Acuity in Patients With Rod-Cone Degeneration. Invest Ophthalmol Vis Sci. 2019. PMID: 31335944. doi:10.1167/iovs.18-26245
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。