文献速递眼底病与葡萄膜炎

用计算机模拟行走任务测量非新生血管性年龄相关性黄斑变性患者动态自我感知焦虑与担忧水平

Measuring dynamic levels of self-perceived anxiety and concern during simulated mobility tasks in people with non-neovascular age-related macular degeneration.
PubMed 文献 · Br J Ophthalmol · 2019-07-09

研究用18段第一视角模拟行走影片测量干性年龄相关性黄斑变性(AMD)患者自我感知焦虑或担忧,记录按键压力。早期/无AMD组8人、中期AMD组7人、地图样萎缩组15人;中期AMD或地图样萎缩组按键压力高于早期/无AMD组(Kruskal-Wallis p=0.04),上下楼梯和低亮度场景组间差异最大(p<0.001)。

要点

  • 中期AMD或地图样萎缩患者在日常行走中可能体验更高水平的担忧。
  • 上下楼梯及低亮度场景是组间差异最大的事件(p<0.001)。
  • 该计算机测试可识别患者具体担忧场景,有助于患者管理和公众教育。

核心结论

  • 中期AMD或地图样萎缩患者在日常行走中可能体验更高水平的担忧。
  • 该测试能突出患者具体担忧的场景,结果有助于患者管理和公众了解AMD的日常影响。

研究设计与样本

  • 研究向参与者展示18段第一视角计算机模拟行走影片,要求其在会引起自我感知焦虑或担忧的场景中按键,全程记录按键压力并生成与影片时间点对齐的压力轨迹。
  • 参与者按AMD严重程度分组:早期/无AMD组8人、中期AMD组7人、地图样萎缩组15人;生成各组自举法置信区间并检查组间差异最大的事件。

主要发现

  • 早期/无AMD组、中期AMD组、地图样萎缩组的中位(IQR)logMAR视力分别为0.04(-0.04, 0.18)、0.26(0.10, 0.40)、0.32(0.20, 0.56)。
  • 中期AMD或地图样萎缩组记录到的按键压力大于早期/无AMD组(Kruskal-Wallis p=0.04)。
  • 涉及上下楼梯的4个事件和低亮度条件下的3个事件组间差异最大(p<0.001)。

临床怎么用

  • 作者认为该测试结果有助于患者管理,并可用于教育公众了解AMD的日常影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To assess response to real-world mobility scenarios in people with dry age-related macular degeneration (AMD) using a computer-based test. METHODS: Participants were shown 18 point-of-view computer-based movies simulating walking through real-world scenarios, and pressed a button during scenes which would cause them self-perceived anxiety or concern in their day-to-day life. Button pressure was recorded throughout. Pressure traces were generated, which aligned with each movie time point. Group averages based on AMD severity were generated. Bootstrapped confidence intervals (CIs) for responses by group were generated around traces. Traces were examined to discover events causing the greatest differences between groups. RESULTS: Participants had early/no AMD (n=8), intermediate AMD (n=7) or geographic atrophy (n=15 (GA)). Median (IQR) logMAR visual acuity was 0.04 (-0.04, 0.18), 0.26 (0.10, 0.40) and 0.32 (0.20, 0.56), respectively. Participants with intermediate AMD or GA recorded greater pressure than those with early and no AMD (Kruskal-Wallis, p=0.04). Four events involving navigating stairs and three under low luminance elicited greatest differences between groups (p<0.001). CONCLUSION: People with intermediate AMD or GA likely experience higher levels of concern associated with mobility. The test highlights areas of specific concern. Results should be useful in patient management and educating the public about the everyday effects of AMD.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Taylor DJ, Smith ND, Jones PR, et al. Measuring dynamic levels of self-perceived anxiety and concern during simulated mobility tasks in people with non-neovascular age-related macular degeneration. Br J Ophthalmol. 2019. PMID: 31289034. doi:10.1136/bjophthalmol-2019-313864

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。