高分辨率光学相干断层扫描在眼表鳞状肿瘤手术治疗中的应用:一项先导研究
这项前瞻性先导研究纳入8例接受切除术的眼表鳞状肿瘤(OSSN)患者,术前用高分辨率光学相干断层扫描(HR-OCT)识别肿瘤结膜边界并术中转移标记,所有8眼HR-OCT确定的结膜肿瘤边界均与病理证实的边界标记一致。作者认为HR-OCT有潜力预测OSSN的组织学肿瘤边界,并指出需进一步改进HR-OCT技术并将其整合入显微镜以实现实时成像。
要点
- 8眼OSSN术前HR-OCT识别的结膜肿瘤边界与病理证实的边界标记全部一致。
- 作者认为HR-OCT有潜力预测OSSN的组织学肿瘤边界。
- 作者指出需改进HR-OCT技术并整合入显微镜以实现实时成像。
核心结论
- HR-OCT有潜力预测OSSN的组织学肿瘤边界,光学识别肿瘤边界有可能减少残留阳性切缘的发生并尽量减少健康组织切除。
- 需要进一步改进HR-OCT技术并将其整合入显微镜以实现实时成像,以进一步完善该技术。
研究设计与样本
- 前瞻性研究,纳入8例接受切除术的OSSN患者的8眼。
- 术前即刻用市售HR-OCT对肿瘤成像以识别肿瘤性病变的结膜边界,将HR-OCT确定的病变边界相对于解剖参考点标测并术中转移。
- 以「不接触」技术从病变可见边缘外4 mm切除肿瘤,标本送病理分析,将组织学肿瘤边界与HR-OCT预测的肿瘤边界进行比较。
主要发现
- 8例患者平均年龄67 ± 9.9岁,7例男性,7例白人,族裔上3例西班牙裔。
- 8个肿瘤均位于球结膜且位于暴露区,7个位于角膜缘,5个存在角膜扩展。
- 平均肿瘤面积17.5 ± 11.1 mm2。
- 临床上2个肿瘤为白斑状、1个为乳头状、3个为胶冻状。
- 所有眼中HR-OCT识别的结膜肿瘤边界均与病理证实的边界标记一致。
局限性
- 作者指出需要进一步改进HR-OCT技术并将其整合入显微镜以实现实时成像,以进一步完善该技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate whether high-resolution optical coherence tomography (HR-OCT) can detect histologic tumor margins of ocular surface squamous neoplasia (OSSN). METHODS: Eight eyes of 8 patients with OSSN undergoing excision were studied prospectively. Immediately before surgery, the tumor was imaged using commercially available HR-OCT to identify the conjunctival margins of the neoplastic lesion. The tumor borders of the lesion determined by HR-OCT were mapped in relation to an anatomic reference point and transferred intraoperatively. The tumor was excised with 4-mm margins from the visible edge of the lesion with a "no-touch" technique. The specimens were sent for pathologic analysis and the histologic tumor margin was compared to the HR-OCT predicted tumor border. RESULTS: Mean age of the 8 patients was 67 ± 9.9 years. Seven were male, 7 were white, and, ethnically, 3 were Hispanic. All 8 tumors were bulbar and in the exposure zone. Seven tumors were limbal. Corneal extension was present in 5. Mean tumor area was 17.5 ± 11.1 mm2. Clinically, 2 of the tumors were leukoplakic, 1 papillomatous, and 3 gelatinous. A conjunctival tumor margin identified with the HR-OCT coincided with the pathologically confirmed margin mark in all eyes. CONCLUSIONS: HR-OCT has the potential to predict histologic tumor margins in OSSN. Optical identification of tumor margins could potentially decrease the incidence of residual positive margins and minimize healthy tissue removal. Advances in HR-OCT technology and integration into a microscope for "real-time" imaging are needed to further improve this technique. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.
引用
- Karp CL, Mercado C, Venkateswaran N, et al. Use of High-Resolution Optical Coherence Tomography in the Surgical Management of Ocular Surface Squamous Neoplasia: A Pilot Study. Am J Ophthalmol. 2019. PMID: 31163136. doi:10.1016/j.ajo.2019.05.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。