文献速递角膜与眼表疾病白内障与屈光手术

角膜地形图可疑圆锥角膜患者的角膜生物力学特性研究

[Study on corneal biomechanical properties of suspicious keratoconus patients in corneal topography].
PubMed 文献 · Zhonghua Yan Ke Za Zhi · 2019-01-01

横断面研究纳入天津市眼科医院屈光手术中心206例(325只眼)近视或近视散光患者,按Pentacam Belin分析综合偏差分析值分为疑似组57例(71只眼,1.6~3.0)与对照组149例(254只眼,<1.6),疑似组角膜厚度偏薄、曲率偏陡、生物力学特性偏弱。

要点

  • 综合偏差分析值1.6~3.0的疑似组K1、K2、Km均较对照组明显偏大(均P<0.001)。
  • 疑似组A1-Velocity[(0.152±0.015) m/s]和DA[(1.050±0.090) mm]较对照组明显偏大。
  • 调整CCT、眼压、年龄、屈光度后,A1-Length、A1-Velocity和DA仍有差异。

核心结论

  • 综合偏差分析值可疑人群角膜厚度偏薄、角膜曲率偏陡、角膜生物力学特性偏弱,该分析值对角膜屈光手术前筛查圆锥角膜、合理选择术式以降低术后角膜扩张有重要提示作用。

研究设计与样本

  • 横断面研究,收集2015年3月至2016年1月天津市眼科医院屈光手术中心屈光不正患者206例(325只眼),男110例(213只眼)、女96例(153只眼),年龄(22.68±5.20)岁。
  • 综合偏差分析值1.6~3.0者57例(71只眼)纳入疑似组,<1.6者149例(254只眼)纳入对照组。
  • 采用可视化角膜生物力学分析仪测量角膜生物力学参数,Pentacam三维眼前节分析系统行Belin/Ambrosio Enhanced Ectasia分析。
  • 采用两独立样本t检验和多重线性回归模型对比两组生物力学参数,Pearson线性相关分析检验数据间相关性。

主要发现

  • 与对照组相比,疑似组K1、K2和Km明显偏大(均P<0.001)。
  • 疑似组CCT、A1-Length、A2-Length和RoC均明显偏小(P<0.001,<0.001,0.004,0.001)。
  • 疑似组A1-Velocity[(0.152±0.015) m/s]和DA[(1.050±0.090) mm]明显偏大(t=4.348,2.708;P<0.001,0.007)。
  • 疑似组CCT与A1-Time、A1-Length、A2-Length、A2-Velocity和眼压均呈正相关(r=0.305,0.324,0.238,0.346,0.316;P<0.05)。
  • 疑似组K1与A1-Length呈负相关(r=-0.361,P=0.002),K2与A1-Length和RoC均呈负相关(r=-0.369,-0.242;P=0.002,0.043),Km与A1-Length呈负相关(r=-0.373,P=0.001)。

关键数值与推荐

  • 疑似组综合偏差分析值为1.6~3.0,对照组为<1.6。

临床怎么用

  • 作者认为该分析值对角膜屈光手术前筛查圆锥角膜、合理选择术式以降低屈光手术后角膜扩张有重要提示作用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To explore the characteristics and significance of corneal biomechanics in patients with suspicious total deviation value in Belin/Ambrosio Enhanced Ectasia Display of Pentacam corneal topography. Methods: In this cross-sectional study, 206 patients (325 eyes) with myopia or myopic astigmatism were collected from refractive surgery center of Tianjin Eye Hospital. Among them, 110 males(213 eyes) and 96 females (153 eyes) were aged (22.68±5.20) years. 57 patients (71 eyes) with a total deviation value of 1.6-3.0 in the Pentacam corneal topography were included in the suspicious group, and 149 patients (254 eyes) of<1.6 were included in the control group. The values of the first applanation time (A1-Time), first applanation length (A1-Length), first applanation velocity (A1-Velocity), second applanation time (A2-Time), second applanation length (A2-Length), second applanation velocity(A2-Velocity), highest concavity time (HC-time), highest concavity deformation amplitude (DA), highest concavity peak distance (PD), highest concavity radius (HC-Radius, RoC), intraocular pressure were measured using the corneal visualization Scheimpflug technology. The total deviation value in Belin/Ambrosio Enhanced Ectasia Display were measured with a Pentacam. The biomechanical parameters of the suspicious group were compared with the normal group by the two independent samples t test and the identity regression analyses. The data correlation was performed using Pearson linear correlation analysis. Results: Compared with the D normal group, the K1, K2 and Km of D suspicious group were significantly increased (P<0.001). A1-Velocity [(0.152±0.015) m/s] and DA[(1.050±0.090) mm] were significantly increased (t=4.348, 2.708; P<0.001, 0.007), while the CCT, A1-Length, A2-Length and RoC were significantly decreased (P<0.01) in suspicious group. In suspicious group, there was a significant correlation between A1-Time, A1-Length, A2-Length, A2-Velocity, IOP and CCT(r=0.305, 0.324, 0.238, 0.346, 0.316; P<0.05). There was a significant correlation between the anterior surface refractive power K1 and the A1-Length (r=-0.361, P=0.002), and there was a significant correlation between the A1-Length, RoC and anterior surface refractive power K2 (r=-0.369, -0.242; P=0.002, 0.043). There was a significant correlation between anterior surface refractive power Km and A1-Length (r=-0.373, P=0.001). After adjusting the confounding factors between two groups by the identity regression analyses, the A1-Length (P=0.003), A1-Velocity (P<0.001) and DA (P=0.002) were still significant differences. Conclusions: In total deviation value suspicious group, the corneal thickness was thinner, corneal curvature became steeper and the corneal biomechanical properties were weaker. It is important to screen keratoconus before corneal refractive surgery and choose a reasonable surgical procedure to reduce corneal dilatation after refractive surgery. (Chin J Ophthalmol,2019, 55: 442-447). 目的: 探讨Pentacam角膜地形图Belin分析中综合偏差分析值为可疑的人群角膜生物力学的特性及其意义。 方法: 横断面研究。收集2015年3月至2016年1月于天津市眼科医院屈光手术中心就诊的屈光不正患者206例(325只眼),其中男性110例(213只眼),女性96例(153只眼),年龄(22.68±5.20)岁。将Pentacam角膜地形图Belin分析中综合偏差分析值1.6~3.0者57例(71只眼)纳入疑似组,<1.6者149例(254只眼)纳入对照组。应用可视化角膜生物力学分析仪对患者的角膜生物力学参数包括第1次压平时间(A1-Time),第1次压平角膜长度(A1-Length),第1次压平速度(A1-Velocity),第2次压平时间(A2-Time),第2次压平角膜长度(A2-Length),第2次压平速度(A2-Velocity),产生最大压陷的时间(HC-time),最大压陷时的变形幅度(DA),最大压陷时的峰距(PD),最大压陷时的反向曲率半径(RoC),非接触式眼压等进行测量和分析;应用Pentacam三维眼前节分析系统,对患者进行Belin/Ambrosio Enhanced Ectasia分析检测角膜中央厚度(CCT)、3 mm区平面中心曲率(K1)及徒中心曲率(K2)、角膜平均曲率(Km),记录患者的综合偏差分析值。通过两独立样本t检验和多重线性回归模型对疑似组的生物力学参数与对照组的生物力学参数进行对比分析;应用Pearson线性相关分析进行数据间相关性检验。 结果: 与综合偏差分析值对照组相比,疑似组的K1、K2和Km明显偏大(均P<0.001);疑似组的CCT、A1-Length、A2-Length和RoC均明显偏小(P<0.001,< 0.001,0.004,0.001),A1-Velocity[(0.152±0.015)m/s]和DA[(1.050±0.090)mm]明显偏大(t=4.348,2.708;P<0.001,0.007)。疑似组的角膜中央厚度(CCT)与A1-Time、A1-Length、A2-Length、A2-Velocity和眼压之间均呈正相关(r=0.305,0.324,0.238,0.346,0.316;P<0.05),K1与A1-Length之间呈负相关(r=-0.361,P=0.002),K2与A1-Length和RoC之间均呈负相关(r=-0.369,-0.242;P=0.002,0.043),角膜前表面曲率Km与A1-Length之间呈负相关(r=-0.373,P=0.001)。使用多重线性回归模型分析,调整两组间的CCT、眼压、年龄、屈光度等影响生物力学的混杂因素后,其A1-Length(P=0.003)、A1-Velocity(P<0.001)和DA(P=0.002)仍有差异。 结论: 角膜地形图Belin分析中综合偏差分析值可疑的人群角膜厚度偏薄,角膜曲率偏陡,角膜生物力学特性偏弱,该分析值对角膜屈光手术前筛查圆锥角膜、合理的选择术式以降低屈光手术后角膜扩张有重要提示作用。(中华眼科杂志,2019,55:442-447).

来源:Zhonghua Yan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Zhang YH, Wang Y, Li LY, et al. [Study on corneal biomechanical properties of suspicious keratoconus patients in corneal topography]. Zhonghua Yan Ke Za Zhi. 2019. PMID: 31189274. doi:10.3760/cma.j.issn.0412-4081.2019.06.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。