正常与青光眼人虹膜的杨氏模量测定
研究采用原子力显微镜测定18例青光眼患者(原发性闭角型青光眼与原发性开角型青光眼各半)及5例正常对照者虹膜组织的杨氏模量;正常对照虹膜杨氏模量最低(0.85±0.31 kPa),原发性闭角型青光眼虹膜最高(2.40±0.82 kPa),且显著高于正常对照(P=0.005)和原发性开角型青光眼虹膜(P=0.001);原发性开角型青光眼虹膜(1.13±0.36 kPa)与正常对照无显著差异(P=0.511)。
要点
- 正常对照虹膜杨氏模量为0.85±0.31 kPa,为三组中最低。
- 原发性闭角型青光眼虹膜杨氏模量为2.40±0.82 kPa,显著高于正常对照(P=0.005)。
- 原发性开角型青光眼虹膜杨氏模量1.13±0.36 kPa与正常对照无显著差异(P=0.511)。
核心结论
- 虹膜组织生物力学特性的差异可能在闭角型青光眼发病机制中起重要作用。
- 本研究提示闭角型青光眼与开角型青光眼眼之间存在根本性的生物力学差异。
- 理解这一基础为更好地认识疾病病理并研究针对该机制的治疗策略创造了新平台。
研究设计与样本
- 研究采用原子力显微镜评估正常对照与青光眼人虹膜的生物力学特性(杨氏模量)。
- 虹膜组织来自18例青光眼受试者(原发性闭角型青光眼与原发性开角型青光眼眼数相等)及5例接受择期眼科手术的正常受试者。
- 使用Nanowizard II BioAFM在室温下进行力测量,虹膜样本在测量期间浸于液体介质(含0.1% BSA的PBS)中。
- 采用JPK Data Processing Software对每条记录曲线计算杨氏模量,该软件使用球形压头的赫兹接触模型拟合延伸曲线。
主要发现
- 正常对照虹膜杨氏模量最低(0.85±0.31 kPa),原发性闭角型青光眼患者虹膜杨氏模量最高(2.40±0.82 kPa)。
- 原发性闭角型青光眼虹膜杨氏模量显著高于正常对照(P=0.005)。
- 原发性闭角型青光眼虹膜杨氏模量显著高于原发性开角型青光眼虹膜(P=0.001)。
- 原发性开角型青光眼虹膜杨氏模量(1.13±0.36 kPa)与正常对照相比无显著差异(P=0.511)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the biomechanical properties (Young's modulus) of normal (control) and glaucomatous human iris using atomic force microscopy (AFM). METHODS: Iris tissue obtained from eighteen glaucomatous subjects (equal number of eyes with primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) and five normal subjects who underwent elective eye surgery were subjected to the estimation of Young's modulus by AFM. Force measurements were done at room temperature using Nanowizard II BioAFM. The iris samples were immersed in the liquid media (PBS with 0.1% BSA) during force measurements. Young's modulus values were calculated for each recorded curve using JPK Data Processing Software, which uses a Hertz's contact model for spherical indenters fitted to the extend curves. RESULTS: The iris from the normal controls had the least Young's modulus (0.85 ± 0.31 kPa) while those from PACG patients had the highest Young's modulus (2.40 ± 0.82 kPa). The Young's modulus of PACG iris was significantly higher compared to that of the normal controls (P = 0.005) and POAG iris (P = 0.001). However, there was no significant difference in the Young's modulus of POAG iris (1.13 ± 0.36 kPa) compared to that of the normal controls (P = 0.511). CONCLUSIONS: Variations in biomechanical properties of iris tissue may have a significant role in the pathogenesis of angle closure glaucoma. This study suggests the existence of fundamental biomechanical differences in eyes with angle closure versus open angle glaucoma. An understanding of this basis creates a new platform to understand disease pathology better and work on therapeutic strategies that will address the same.
引用
- Narayanaswamy A, Nai MH, Nongpiur ME, et al. Young's Modulus Determination of Normal and Glaucomatous Human Iris. Invest Ophthalmol Vis Sci. 2019. PMID: 31242291. doi:10.1167/iovs.18-26455
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。