文献速递青光眼

短暂性眼压波动:来源、幅度、频率及相关机械能

Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

研究在6只清醒、自由活动的非人灵长类9只正常眼内植入无线遥测系统,以500 Hz连续监测眼压16至451天,识别短暂性眼压波动的来源并量化其频率、幅度及累积机械能。结果显示波动来源于眨眼、扫视和眼脉动幅度,可高于瞬时基线14 mm Hg(>100%),清醒时每小时约10000次,其中约2000至5000次高于基线5 mm Hg(约40%),占清醒时总累积眼压相关机械能最高17%(平均12%)。

要点

  • 短暂性眼压波动来源于眨眼、扫视和眼脉动幅度,幅度可高于瞬时基线14 mm Hg。
  • 清醒时每小时约10000次短暂性眼压波动,其中约2000至5000次高于基线5 mm Hg。
  • 短暂性眼压波动占清醒时总累积眼压相关机械能最高17%,平均12%。

核心结论

  • 短暂性眼压波动频繁发生,构成眼内总眼压负荷的一大部分,未来细胞力转导、眼生物力学和临床结局研究应考虑其影响。
  • 若人类眼压动力学相似,临床单次眼压测量不足以捕捉真实眼压。

研究设计与样本

  • 在6只清醒、自由活动的非人灵长类9只正常眼中,使用经前房插管测压法每两周校准的已验证全植入无线遥测系统,以500 Hz监测眼压16至451天。
  • 采用时间同步高清视频分析识别短暂性眼压波动的来源。

主要发现

  • 单眼眼压分布宽泛,并在从秒到秒至天到天的多个时间尺度上变化。
  • 短暂性眼压波动来源于眨眼、扫视和眼脉动幅度,可高于瞬时基线14 mm Hg(>100%)。
  • 短暂性眼压波动在清醒时每小时约发生10000次,其中约2000至5000次高于基线5 mm Hg(约40%)。
  • 短暂性眼压波动占清醒时眼必须承受的总累积眼压相关机械能最高17%(平均12%)。

临床怎么用

  • 原文未据此给出推荐,作者认为未来细胞力转导、眼生物力学和/或临床结局研究应考虑短暂性眼压波动;若人类眼压动力学相似,临床单次眼压测量不足以捕捉真实眼压。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To characterize intraocular pressure (IOP) dynamics by identifying the sources of transient IOP fluctuations and quantifying the frequency, magnitude, associated cumulative IOP-related mechanical energy, and temporal distribution. METHODS: IOP was monitored at 500 Hz for periods of 16 to 451 days in nine normal eyes of six conscious, unrestrained nonhuman primates using a validated, fully implanted wireless telemetry system. IOP transducers were calibrated every two weeks via anterior chamber cannulation manometry. Analysis of time-synchronized, high-definition video was used to identify the sources of transient IOP fluctuations. RESULTS: The distribution of IOP in individual eyes is broad, and changes at multiple timescales, from second-to-second to day-to-day. Transient IOP fluctuations arise from blinks, saccades, and ocular pulse amplitude and were as high as 14 mm Hg (>100%) above momentary baseline. Transient IOP fluctuations occur ∼10,000 times per waking hour, with ∼2000 to 5000 fluctuations per hour greater than 5 mm Hg (∼40%) above baseline. Transient IOP fluctuations account for up to 17% (mean of 12%) of the total cumulative IOP-related mechanical energy that the eye must withstand during waking hours. CONCLUSIONS: Transient IOP fluctuations occur frequently and comprise a large and significant portion of the total IOP loading in the eye and should, therefore, be considered in future studies of cell mechanotransduction, ocular biomechanics, and/or clinical outcomes where transient IOP fluctuations may be important. If IOP dynamics are similar in humans, clinical snapshot IOP measurements are insufficient to capture true IOP.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Turner DC, Edmiston AM, Zohner YE, et al. Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy. Invest Ophthalmol Vis Sci. 2019. PMID: 31212310. doi:10.1167/iovs.19-26600

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。