文献速递眼底病与葡萄膜炎

近红外自发荧光改善视网膜激光损伤的诊断

Improved Diagnosis of Retinal Laser Injuries Using Near-Infrared Autofluorescence.
PubMed 文献 · Am J Ophthalmol · 2019-06-12

该回顾性观察性病例系列纳入2个学术中心的12例手持激光视网膜损伤患者,评估近红外自发荧光(NIR-AF)的诊断价值。所有病例NIR-AF均检出特征性病灶(中心高荧光伴周围低荧光),其他影像表现不一,B-AF仅见细微改变。作者提出,对疑似手持激光黄斑损伤者,应将NIR-AF纳入检查。

要点

  • 12例手持激光视网膜损伤患者中,NIR-AF成像全部检出与激光损伤一致的病灶。
  • NIR-AF示病灶中心高荧光伴周围低荧光,病灶数目和范围因患者而异。
  • 彩色眼底照相、OCT与B-AF表现不一,B-AF仅见细微改变。

核心结论

  • 视网膜激光损伤的诊断和完整范围以NIR-AF显示最佳,其他影像模态结果不一。
  • 作者提出,对疑似手持激光暴露所致黄斑损伤的患者,检查时应纳入NIR-AF。

研究设计与样本

  • 回顾性观察性病例系列,纳入2个学术中心的12例手持激光视网膜损伤患者。

主要发现

  • 所有病例中,NIR-AF成像均检出与视网膜激光损伤一致的病灶。
  • 病灶呈中心高荧光伴周围低荧光的特征性表现,但病灶数目和范围因患者而异。
  • 彩色眼底照相可见局限性色素改变,OCT可见椭圆体带中断或外核层改变,B-AF仅见细微改变。
  • OCT表现可与poppers视网膜病变或日光性黄斑病变相似的黄斑疾病,可用NIR-AF成像鉴别。

关键数值与推荐

  • NIR-AF病灶特征:中心高荧光伴周围低荧光。
  • OCT表现:椭圆体带中断或外核层改变。

临床怎么用

  • 作者提出,对疑似手持激光暴露所致黄斑损伤的患者,检查时应纳入NIR-AF。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess whether near infrared autofluorescence (NIR-AF) imaging is a useful imaging modality in the diagnosis of handheld laser retinal injuries. DESIGN: Retrospective observational case series. METHODS: Twelve patients identified to have handheld laser retinal injuries were included at 2 academic centers. Patients underwent ophthalmic assessment and retinal imaging including fundus photography, optical coherence tomography (OCT), conventional blue autofluorescence (B-AF), and NIR-AF imaging. RESULTS: In all cases, lesions consistent with retinal laser injury were detected by NIR-AF imaging. The lesions showed a characteristic appearance with central hyperfluorescence and surrounding hypofluorescence, although the number and extent of lesions varied between patients. Findings using other imaging modalities were variable: on color fundus photography these included localized pigmentary changes and on OCT imaging an ellipsoid zone interruption or outer nuclear layer changes. Only subtle changes were evident on B-AF imaging. Other macular conditions, such as poppers retinopathy or solar maculopathy, which may have similar findings on OCT imaging as laser damage, can be differentiated using NIR-AF imaging. CONCLUSION: An increased incidence of retinal injuries secondary to handheld lasers has been reported in recent years. We show that the diagnosis and full extent of retinal laser injuries is best demonstrated by NIR-AF, as other modalities give variable results. We propose that NIR-AF should be included when investigating patients suspected of macular injury secondary to exposure to handheld lasers.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. De Silva SR, Neffendorf JE, Birtel J, et al. Improved Diagnosis of Retinal Laser Injuries Using Near-Infrared Autofluorescence. Am J Ophthalmol. 2019. PMID: 31199894. doi:10.1016/j.ajo.2019.06.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。