文献速递眼底病与葡萄膜炎

光学相干断层扫描血管成像评估的糖尿病视网膜病变视网膜血管反应性受损

Impaired Retinal Vascular Reactivity in Diabetic Retinopathy as Assessed by Optical Coherence Tomography Angiography.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

研究纳入22只健康对照眼和16只糖尿病视网膜病变(DR)眼,用扫频源光学相干断层扫描血管成像(SS-OCTA)检测高氧、高碳酸和室内空气条件下的血管骨架密度(VSD)与血管直径指数(VDI)。结果显示健康对照对三种气体条件均有显著反应,而DR眼仅对高氧有显著反应,对高碳酸无显著反应。

要点

  • DR眼在高氧与室内空气、高氧与高碳酸条件间VSD有显著差异,高碳酸与室内空气间无显著差异。
  • 健康对照三种气体条件间VSD均有显著差异。
  • VDI结果与VSD相似,提示DR视网膜毛细血管优先对高氧而非高碳酸反应。

核心结论

  • SS-OCTA评估的DR受试者视网膜毛细血管优先对高氧反应而不对高碳酸反应,健康对照对两者均反应,这种血管反应性差异可能提示DR的潜在病理生理。

研究设计与样本

  • 研究纳入22只健康对照眼和16只DR眼,使用市售扫频源光学相干断层扫描血管成像(SS-OCTA)系统采集图像,通过非重复呼吸装置分别给予100% O2、5% CO2和室内空气三种气体条件。

主要发现

  • VSD的混合模型ANOVA发现显著的个体内气体效应(F[2, 70]=20.3,P<0.001)、组间效应(F[1, 35]=6.9,P=0.001)和交互效应(F[2, 70]=4.6,P=0.03)。
  • 事后两两比较发现健康对照三种气体条件间VSD均有显著差异。
  • DR受试者高氧与室内空气间、高氧与高碳酸间VSD有显著差异,高碳酸与室内空气间无显著差异。
  • VDI结果与VSD相似。

关键数值与推荐

  • VSD的混合模型ANOVA显示个体内气体效应F[2, 70]=20.3,P<0.001;组间效应F[1, 35]=6.9,P=0.001;交互效应F[2, 70]=4.6,P=0.03。
  • 统计显著性定义为P<0.05。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess retinal vascular reactivity in healthy controls and subjects with diabetic retinopathy (DR). METHODS: A total of 22 healthy control eyes and 16 eyes with DR were enrolled. Images were acquired using a commercially available swept-source optical coherence tomography angiography (SS-OCTA) system. Three conditions were tested for each patient (hyperoxia, hypercapnia, and room-air) by employing a non-rebreathing apparatus that delivered appropriate gas mixtures (100% O2, 5% CO2, room air). Vessel skeleton density (VSD) and vessel diameter index (VDI) were compared between the conditions using mixed-model ANOVA adjusting for age and hypertension. Significant gas or interaction effects were followed by a Bonferroni adjusted pairwise post hoc analysis. Statistical significance was defined at P < 0.05. RESULTS: The mixed-model ANOVA of the VSD found a significant intraindividual gas effect (F[2, 70] = 20.3, P < 0.001) and intergroup effect (F[1, 35] = 6.9, P = 0.001), and interaction effects (F[2, 70] = 4.6, P = 0.03). The post hoc pairwise comparison found significant differences among all three gas conditions in the healthy controls. In the subjects with DR, there were significant differences in VSD between hyperoxic and room air, and between hyperoxic and hypercapnic conditions, but not between hypercapnic and room-air conditions. Similar results were found for VDI. CONCLUSIONS: The retinal capillaries, assessed with SS-OCTA, in subjects with DR preferentially reacted to hyperoxia but not hypercapnia, while the healthy controls reacted to both. The difference in the vascular reactivity may be indicative of the underlying pathophysiology of DR.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Ashimatey BS, Green KM, Chu Z, et al. Impaired Retinal Vascular Reactivity in Diabetic Retinopathy as Assessed by Optical Coherence Tomography Angiography. Invest Ophthalmol Vis Sci. 2019. PMID: 31173077. doi:10.1167/iovs.18-26417

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。