文献速递角膜与眼表疾病

条带泪液半月测量法在小鼠泪液量评估中的应用

The Application of Strip Meniscometry to the Evaluation of Tear Volume in Mice.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

本研究采用改良条带泪液半月测量法(SMTube for mice,SMTM)评估小鼠泪液量,对11只9周龄C57BL/6J野生型雄性小鼠(11只右眼)连续2天每天5小时暴露于小隔间内风扇诱导干眼。结果显示,干眼环境暴露后SMTM均值从3.89±0.603 mm降至3.09±0.625 mm(P=0.0078),且SMTM与泪膜破裂时间呈强正相关,与荧光素和丽丝胺绿染色评分呈强线性负相关。作者认为SMTM能快速测量小鼠最小泪液量,与泪液功能参数相关性良好,似乎是小鼠干眼评估中有前景的新方法。

要点

  • 干眼环境暴露后小鼠SMTM均值由3.89±0.603 mm降至3.09±0.625 mm(P=0.0078)。
  • SMTM与泪膜破裂时间呈强正相关,与荧光素和丽丝胺绿染色值呈强线性负相关。
  • 作者认为SMTM似乎是小鼠干眼评估中有前景的新方法。

核心结论

  • SMTM能够快速测量小鼠的最小泪液量,并与泪液功能参数相关性良好,似乎是小鼠干眼评估中有前景的新方法。

研究设计与样本

  • 研究对11只9周龄C57BL/6J野生型雄性小鼠(11只右眼)通过连续2天每天5小时暴露于小隔间内风扇诱导干眼。
  • 研究进行泪液功能测试,包括用于泪液量评估的小鼠SMTube(SMTM)、泪膜破裂时间、荧光素染色评分和丽丝胺绿染色评分,并评估SMTM与其他泪液功能参数的相关性。

主要发现

  • SMTM均值在干眼环境暴露前为3.89±0.603 mm,暴露后为3.09±0.625 mm(P=0.0078)。
  • Spearman秩相关检验显示SMTM与泪膜破裂时间呈强正相关,与荧光素和丽丝胺绿染色值呈强线性负相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Strip meniscometry quantitatively measures the volume of tears in the tear meniscus and has been reported to diagnose dry eyes in clinical settings conveniently, easily, and rapidly. In this study, we used a modified strip meniscometry to assess the applicability of measuring the tear volume in mice in experimental settings. METHODS: Dry eye was induced in 11 9-week-old C57BL/6J wild-type male mice (11 right eyes) by exposing them to an air fan inside a small compartment for 5 hours for 2 consecutive days. Tear function tests, including the SMTube for mice (SMTM) for tear volume evaluation, break-up time, fluorescein staining score, and lissamine green staining score, were performed. The correlation between SMTM and other tear function parameters was assessed. RESULTS: The mean SMTM value was 3.89 ± 0.603 mm before and 3.09 ± 0.625 mm after dry environment exposure (P = 0.0078*). The Spearman's correlation by rank test showed a strong positive correlation between SMTM and tear film break-up time and a strong linear negative correlation with fluorescein and lissamine green values. CONCLUSIONS: The SMTM was capable of rapidly measuring the minimum tear volume in mice and correlated well with tear function parameters and appears to be a promising new modality in the evaluation of dry eyes in mice.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Shinzawa M, Dogru M, Miyasaka K, et al. The Application of Strip Meniscometry to the Evaluation of Tear Volume in Mice. Invest Ophthalmol Vis Sci. 2019. PMID: 31091316. doi:10.1167/iovs.19-26850

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。