常规与飞秒激光辅助白内障手术对角膜内皮细胞密度及中央角膜厚度变化的比较:一项随机对照临床试验
本 intraindividual 随机对照临床试验纳入 67 例患者共 134 只配对眼,一眼行飞秒激光辅助白内障手术(FLACS),对侧眼行常规超声乳化白内障手术(CPS)。术后 1 个月和 3 个月两组内皮细胞密度(ECD)无显著差异,随访期间中央角膜厚度(CCT)均值亦无显著差异。结论认为术后 3 个月随访期内 FLACS 与 CPS 的角膜 ECD 和 CCT 具有可比性。
要点
- 术后 1 个月 ECD:FLACS 组 2370±580 cells/mm2 vs CPS 组 2467±564 cells/mm2(p=0.18)。
- 术后 3 个月 ECD:FLACS 组 2374±527 cells/mm2 vs CPS 组 2433±526 cells/mm2(p=0.19)。
- 随访期间两组平均 CCT 值无显著差异(p>0.05)。
核心结论
- 术后 3 个月随访期内,FLACS 与 CPS 的角膜内皮细胞密度和中央角膜厚度具有可比性。
研究设计与样本
- 采用眼内随机对照临床试验设计,同一患者一眼随机接受 FLACS,对侧眼接受 CPS。
- 飞秒激光预处理包括制作角膜主切口和侧切口、撕囊及晶状体碎核。
- 术前及术后第 1 天、第 1 周、第 1 个月、第 3 个月行非接触式角膜内皮细胞显微镜检查和角膜测厚。
- 共纳入 67 例患者的 134 只配对眼进行分析。
主要发现
- 术后 1 个月 ECD:FLACS 组 2370±580 cells/mm2 vs CPS 组 2467±564 cells/mm2(p=0.18)。
- 术后 3 个月 ECD:FLACS 组 2374±527 cells/mm2 vs CPS 组 2433±526 cells/mm2(p=0.19)。
- 随访期间两组平均 CCT 值无显著差异(p>0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIM: To identify changes in endothelial cell density (ECD) and central corneal thickness (CCT) in eyes undergoing femtosecond laser-assisted cataract surgery (FLACS) compared with conventional phacoemulsification surgery (CPS). METHODS: This is an intraindividual randomised, controlled clinical trial. One eye was randomised to receive FLACS, while the contralateral eye of the same patient received CPS. The femtosecond laser pretreatment included creating main and side-port corneal incisions, capsulotomy and lens fragmentation. Non-contact endothelial cell microscopy and pachymetry were performed preoperatively and at postoperative day 1, week 1, month 1 and month 3. RESULTS: A total of 134 paired eyes from 67 patients were included in the analysis. ECD was not significantly different between the two groups at either postoperative month 1 (2370±580 cells/mm2 and 2467±564 cells/mm2 in FLACS and CPS groups, respectively; p=0.18) or at postoperative month 3 (2374±527 cells/mm2 and 2433±526 cells/mm2 in FLACS and CPS groups, respectively; p=0.19). No significant difference was observed in the mean CCT values between the two groups over the follow-up period (p>0.05). CONCLUSION: Postoperative corneal ECD and CCT were comparable between FLACS and CPS during the 3 months' follow-up period.
引用
- Dzhaber D, Mustafa O, Alsaleh F, et al. Comparison of changes in corneal endothelial cell density and central corneal thickness between conventional and femtosecond laser-assisted cataract surgery: a randomised, controlled clinical trial. Br J Ophthalmol. 2019. PMID: 31097441. doi:10.1136/bjophthalmol-2018-313723
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。