文献速递白内障与屈光手术神经眼科

白内障人工晶状体置换与老年人昼夜节律、认知功能及睡眠的关联

Association of Intraocular Cataract Lens Replacement With Circadian Rhythms, Cognitive Function, and Sleep in Older Adults.
PubMed 文献 · JAMA Ophthalmol · 2019-01-01

该横断面研究在瑞士巴塞尔大学时间生物学中心纳入16名健康老年对照和13例既往白内障已行人工晶状体(IOL)置换的患者,比较蓝光阻断型与紫外线阻断型IOL对光暴露下褪黑素、认知及睡眠的影响。结果显示IOL患者光暴露期间褪黑素升高幅度低于对照,紫外线型IOL患者持续注意力表现优于蓝光阻断型,且慢波睡眠及额区慢波活动高于蓝光阻断型。作者认为优化晶状体光谱透射可能减轻年龄相关的昼夜节律、认知和睡眠不良影响。

要点

  • 白内障IOL置换患者光暴露期间褪黑素升高幅度低于健康老年对照。
  • 紫外线阻断型IOL患者持续注意力表现优于蓝光阻断型IOL患者。
  • 紫外线阻断型IOL患者慢波睡眠比例及首个睡眠周期额区慢波活动高于蓝光阻断型。

核心结论

  • 这些实验室内实证发现提示,优化既往白内障患者晶状体的光谱透射可能减轻年龄相关的昼夜节律、认知和睡眠不良影响。

研究设计与样本

  • 横断面研究,2012年2月至2014年4月在瑞士巴塞尔大学时间生物学中心开展,2012年6月至2018年9月分析。
  • 纳入16名健康老年对照和13例既往白内障已行IOL置换的患者,均未用药且无医学及睡眠共病。

主要发现

  • 光暴露期间褪黑素升高幅度:蓝光阻断组平均23.3%(SEM 2.6%)、紫外线阻断组19.1%(SEM 2.1%),均低于对照组的48.8%(SEM 5.2%),均值差27.7(95%CI 15.4%-41.7%,P<.001)。
  • 光暴露期间及睡后晨间持续注意力表现:紫外线阻断组平均276.9毫秒(SEM 11.1)优于蓝光阻断组348.3毫秒(SEM 17.8),均值差71.4(95%CI 29.5%-113.1%,P=.002)。
  • 慢波睡眠占总睡眠时间比例:紫外线阻断组平均升高13%(SEM 3.4%),高于对照组5.2%(SEM 0.8%),均值差7.9(95%CI 2.4%-13.4%,P=.02)。
  • 首个睡眠周期额区非快速眼动慢波活动(0.75-4.5 Hz):紫外线阻断组平均79.9 μV²/Hz(SEM 13.6)高于蓝光阻断组53.2 μV²/Hz(SEM 10.7),均值差26.7(95%CI 9.2-48.9,P=.03)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Cataract is associated with a progressive decline in light transmission due to the clouding and yellowing of the natural crystalline lens. While the downstream effects of aging lenses include long-term disruption of circadian rhythms, cognitive function, and sleep regulation, it remains unknown whether there is an association of intraocular cataract lens (IOLs) replacement with circadian rhythms, cognition, and sleep. OBJECTIVE: To test whether IOL replacement (blue blocking [BB] or ultraviolet [UV] only blocking) in older patients with previous cataract is associated with the beneficial light effects on the circadian system, cognition, and sleep regulation. DESIGN, SETTING, AND PARTICIPANTS: Cross-sectional study at the Centre for Chronobiology, University of Basel in Switzerland from February 2012 to April 2014, analyzed between June 2012 and September 2018. Sixteen healthy older controls and 13 patients with previous cataract and IOL replacement participated without medication and no medical and sleep comorbidities. EXPOSURES: Three and a half hours of prior light control (dim-dark adaptation), followed by 2 hours of evening blue-enriched (6500 K) or non-blue-enriched light exposure (3000 K and 2500 K), 30 minutes in dim post-light exposure, 8 hours of sleep opportunity, and 2 hours of morning dim light following sleep. MAIN OUTCOMES AND MEASURES: Salivary melatonin, cognitive tests, and sleep structure and electroencephalographic activity to test the association of IOLs with markers of circadian rhythmicity, cognitive performance, and sleep regulation, respectively. RESULTS: The participants included 16 healthy older controls with a mean (standard error of the mean [SEM]) of 63.6 (5.6) years; 8 women and 13 patients with previous cataract (mean [SEM] age, 69.9 [5.2] years; 10 women); 5 patients had UV IOLs and 8 had BB IOLs. Patients with previous cataract and IOLs had an attenuated increase in melatonin levels during light exposure (mean [SEM] increase in the BB group: 23.3% [2.6%] and in the UV lens group: 19.1% [2.1%]) than controls (mean [SEM] increase, 48.8% [5.2%]) (difference between means, 27.7; 95% CI, 15.4%-41.7%; P < .001). Cognitive function, indexed by sustained attention performance, was improved in patients with UV lens (mean [SEM], 276.9 [11.1] milliseconds) compared with patients with BB lens (mean [SEM], 348.3 [17.8] milliseconds) (difference between means, 71.4; 95% CI, 29.5%-113.1%; P = .002) during light exposure and in the morning after sleep. Patients with UV lens had increased slow-wave sleep (mean [SEM] increase, 13% [3.4%]) compared with controls (mean [SEM] increase, 5.2% [0.8%]) (percentage of total sleep time; difference between means, 7.9; 95% CI, 2.4%-13.4%; P = .02) and frontal non-rapid eye movement slow-wave activity (0.75-4.5 Hz) during the first sleep cycle (mean [SEM], 79.9 [13.6] μV2/Hz) compared with patients with BB lens (mean [SEM], 53.2 [10.7] μV2/Hz) (difference between means, 26.7; 95% CI, 9.2-48.9; P = .03). CONCLUSIONS AND RELEVANCE: These in-laboratory empirical findings suggest that optimizing the spectral lens transmission in patients with previous cataract may minimize the adverse age-related effects on circadian rhythms, cognition, and sleep.

来源:JAMA Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Chellappa SL, Bromundt V, Frey S, et al. Association of Intraocular Cataract Lens Replacement With Circadian Rhythms, Cognitive Function, and Sleep in Older Adults. JAMA Ophthalmol. 2019. PMID: 31120477. doi:10.1001/jamaophthalmol.2019.1406

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。