使用30G针头无缝线巩膜内固定三片式人工晶状体新手术技术的1年结果
该研究回顾性分析了8例患者9只眼接受30G针头无缝线巩膜内固定后房型三片式人工晶状体的1年结果。视力从术前Snellen 20/309提高至术后12个月Snellen 20/27(P=0.03)。短期并发症包括眼压升高(n=4)和角膜水肿(n=2),长期并发症包括上方襻暴露(n=1)和反复前房炎症(n=1)。作者认为该新技术在术后1年耐受良好。
要点
- 30G针头无缝线巩膜内固定三片式人工晶状体术后1年视力由Snellen 20/309提高至20/27(P=0.03)。
- 短期并发症为眼压升高(n=4)和角膜水肿(n=2),长期并发症为上方襻暴露(n=1)和反复前房炎症(n=1)。
- 作者认为该手术技术术后1年耐受良好。
核心结论
- 作者认为,使用30G针头无缝线巩膜内固定三片式人工晶状体的新手术技术在术后1年耐受良好。
研究设计与样本
- 回顾性病历审查,连续纳入8例患者9只眼,接受30G针头无缝线巩膜内固定后房型人工晶状体,要求随访至少1年。
- 术后1个月收集短期数据,术后1年收集长期数据,收集视力、晶状体稳定性、眼压及并发症。
主要发现
- 视力从术前Snellen 20/309提高至术后第12个月Snellen 20/27(P=0.03)。
- 短期并发症包括眼压升高(n=4)和角膜水肿(n=2)。
- 长期并发症包括上方襻暴露(n=1)和反复前房炎症(n=1)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To present the 1-year results of a surgical technique for the sutureless intrascleral fixation of a 3-piece intraocular lens using a 30-gauge needle. METHODS: A retrospective chart review of a consecutive series of 9 eyes of 8 patients who underwent sutureless intrascleral fixation of posterior chamber intraocular lens using a 30-gauge needle was performed. Patients were required to have at least 1 year of follow-up to be included in the analysis. Short-term data were collected 1 month after surgery, and long-term data were collected 1 year after surgery. Data collected included visual acuity, lens stability, intraocular pressure, and the development of complications. RESULTS: Visual acuity improved from Snellen 20/309 preoperatively to Snellen 20/27 at postoperative Month 12 (P = 0.03). Short-term complications included increased intraocular pressure (n = 4) and corneal edema (n = 2). Long-term complications included exposed superior haptic (n = 1) and recurrent anterior chamber inflammation (n = 1). CONCLUSION: The novel surgical technique for sutureless intrascleral fixation of a 3-piece intraocular lens is well tolerated 1 year after surgery.
引用
- Bonnell AC, Polo RN, Shah SP, et al. ONE-YEAR OUTCOMES OF A NOVEL SURGICAL TECHNIQUE FOR SUTURELESS INTRASCLERAL FIXATION OF A THREE-PIECE INTRAOCULAR LENS USING A 30-GAUGE NEEDLE. Retina. 2020. PMID: 31095064. doi:10.1097/IAE.0000000000002560
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。