文献速递青光眼眼底病与葡萄膜炎

剥脱性青光眼中的脉络膜微血管丢失

Choroidal Microvascular Dropout in Pseudoexfoliation Glaucoma.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

横断面研究纳入39只剥脱性青光眼(PXG)眼与39只严重程度匹配的原发性开角型青光眼(POAG)眼,比较脉络膜微血管丢失(CMvD)患病率。PXG组CMvD患病率46.2%低于POAG组79.5%(P=0.002);校正青光眼严重程度后,PXG组发生CMvD的比值比显著更低(OR 0.18-0.21,P<0.01)。

要点

  • PXG眼CMvD患病率46.2%,低于严重程度匹配的POAG眼79.5%(P=0.002)。
  • 两组视野平均缺损(-12.1 vs -12.0 dB)与视盘周围视网膜神经纤维层厚度(71 vs 74 μm)相似。
  • 校正青光眼严重程度后,PXG组CMvD的OR为0.18-0.21(P<0.01)。

核心结论

  • PXG眼的CMvD患病率显著低于POAG眼。

研究设计与样本

  • 横断面研究纳入39只PXG眼(33例患者)和39只青光眼严重程度匹配的POAG眼(34例患者),均接受视野、光学相干断层扫描和光学相干断层扫描血管成像检查。

主要发现

  • PXG组与POAG组视野平均缺损分别为-12.1与-12.0 dB(P=0.96),视盘周围视网膜神经纤维层厚度分别为71与74 μm(P=0.29)。
  • PXG组与POAG组视盘周围浅层血管密度分别为49.7%与51.3%(P=0.35),黄斑旁中心凹血管密度分别为44.8%与45.8%(P=0.33)。
  • CMvD见于18只PXG眼和31只POAG眼,患病率分别为46.2%与79.5%(P=0.002)。
  • 校正青光眼严重程度的多因素分析中,PXG组发生CMvD的比值比显著低于POAG组(OR 0.18-0.21,P<0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the prevalence of choroidal microvasculature dropout (CMvD) in pseudoexfoliation glaucoma (PXG) and disease severity-matched primary open-angle glaucoma (POAG) eyes. METHODS: In a cross-sectional study, 39 eyes with PXG (33 patients) and 39 glaucoma severity-matched POAG eyes (34 patients) underwent visual fields, optical coherence tomography and optical coherence tomography angiography examination. Peripapillary vessel density (VD) was evaluated from the radial peripapillary capillary slab, parafoveal VD was measured on the superficial vascular plexus slab of the macula, and CMvD was evaluated on the choroidal slabs of the optic disc scan. RESULTS: The PXG and POAG groups were similar with respect to average mean deviation on visual fields (-12.1 vs. -12.0 decibel, P = 0.96) and average peripapillary retinal nerve fiber layer thickness on optical coherence tomography (71 vs. 74 μ, P = 0.29). Average peripapillary superficial VD (49.7% vs. 51.3%, P = 0.35) and parafoveal VD (44.8% vs. 45.8%, P = 0.33) were similar between the PXG and POAG groups. CMvD was seen in 18 PXG and 31 POAG eyes (46.2% vs. 79.5%, P = 0.002). On multivariate analysis that accounted for the severity of glaucoma, the odds of CMvD was significantly lower in the PXG group when compared with the POAG group (odds ratio: 0.18-0.21, P < 0.01). CONCLUSIONS: The prevalence of CMvD was significantly lower in the PXG eyes when compared with the POAG eyes.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Pradhan ZS, Rao HL, Dixit S, et al. Choroidal Microvascular Dropout in Pseudoexfoliation Glaucoma. Invest Ophthalmol Vis Sci. 2019. PMID: 31108546. doi:10.1167/iovs.19-26844

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。