文献速递眼底病与葡萄膜炎

分割误差校正对健康眼与糖尿病性黄斑水肿眼光学相干断层扫描血管成像测量的影响

Effect of segmentation error correction on optical coherence tomography angiography measurements in healthy subjects and diabetic macular oedema.
PubMed 文献 · Br J Ophthalmol · 2019-04-29

前瞻性比较性非干预研究纳入20只糖尿病性黄斑水肿(DMO)眼和24只健康眼,评估OCTA分割误差校正对血管密度和内层视网膜厚度的影响。健康眼分割误差率33%,DMO眼100%(p<0.001);校正后平均血管密度无显著变化,但DMO眼平均绝对变化显著更高。作者认为OCTA血管密度测量应检查并手动校正分割误差,尤其存在黄斑水肿时。

要点

  • 健康眼分割误差率33%,DMO眼100%,组间差异有统计学意义(p<0.001)。
  • 校正后平均血管密度在两组均无显著变化(均p>0.05),但DMO眼平均绝对变化显著更高(均p<0.05)。
  • 作者认为OCTA血管密度测量应检查并手动校正分割误差,尤其存在黄斑水肿时。

核心结论

  • 本研究显示视网膜层识别错误及随之的血管密度测量误差发生于全部DMO眼和三分之一健康眼。
  • 作者认为OCTA血管密度测量应检查并手动校正分割误差,尤其存在黄斑水肿时。

研究设计与样本

  • 前瞻性、比较性、非干预性研究,纳入20只DMO眼和24只健康眼,获取黄斑区enface OCTA图像。
  • 由两名专家评估并校正分割误差,记录并比较两组分割误差率及校正后血管密度和内层视网膜厚度变化。

主要发现

  • 两组所有参数的评分者间一致性均极好(组内相关系数≥0.9)。
  • 分割误差率健康眼33%、DMO眼100%(p<0.001)。
  • 9只健康眼(37.5%)和全部DMO眼(100%)至少一项中心凹或中心凹旁血管密度测量出现变化;DMO组浅层和深层毛细血管丛中心凹及中心凹旁血管密度任何变化率均显著更高(均p<0.001)。
  • 校正后平均血管密度(浅层和深层毛细血管丛)在健康眼和DMO眼均无统计学显著变化(均p>0.05),但DMO组血管密度测量的平均绝对变化显著更高(均p<0.05)。
  • DMO组浅层和深层内层视网膜厚度平均绝对变化显著更高(分别为p=0.02和p=0.002)。

临床怎么用

  • 作者认为OCTA血管密度测量中应检查并手动校正分割误差,尤其存在黄斑水肿时。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the impact of segmentation error on vessel density measurements in healthy eyes and eyes with diabetic macular oedema (DMO). METHODS: In this prospective, comparative, non-interventional study, enface optical coherence tomography angiography (OCTA) images of the macula from healthy eyes and eyes with DMO were acquired. Two expert graders assessed and corrected the segmentation error. The rate of segmentation error and the changes in vessel density and inner retinal thickness after correction of the segmentation error were recorded and compared between the two groups. RESULTS: 20 eyes with DMO and 24 healthy eyes were evaluated. Intergrader agreement was excellent (intraclass correlation coefficient ≥0.9) for all parameters in both groups. The rate of segmentation error was 33% and 100% in healthy and diabetic eyes, respectively (p<0.001). Nine healthy eyes (37.5%) and all eyes with DMO (100%) were noted to exhibit a change in at least one of the foveal or parafoveal vessel density measurements. The rate of any change in foveal and parafoveal vessel densities in both the superficial and deep capillary plexus was statistically significantly higher in the diabetic group (all p<0.001). No statistically significant change was observed in mean vessel density (superficial and deep capillary plexuses) after correction of the segmentation error in healthy and DMO eyes (All p>0.05). However, the mean absolute change in the vessel density measurements was statistically significantly higher in the diabetic group (all p<0.05). The mean absolute change in superficial and deep inner retinal thickness was statistically significantly higher in DMO (p=0.02 and p=0.002, respectively). CONCLUSIONS: In this study, misidentification of retinal layers and consequent vessel density measurement error occurred in all eyes with DMO and in one-third of healthy eyes. The segmentation error should be checked and manually corrected in the OCTA vessel density measurements, especially in the presence of macular oedema.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Ghasemi Falavarjani K, Habibi A, Anvari P, et al. Effect of segmentation error correction on optical coherence tomography angiography measurements in healthy subjects and diabetic macular oedema. Br J Ophthalmol. 2019. PMID: 31036586. doi:10.1136/bjophthalmol-2019-314018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。