文献速递眼底病与葡萄膜炎

多焦视网膜电图在检测氯喹与羟氯喹视网膜毒性中的诊断价值

The Diagnostic Utility of Multifocal Electroretinography in Detecting Chloroquine and Hydroxychloroquine Retinal Toxicity.
PubMed 文献 · Am J Ophthalmol · 2019-05-10

该诊断准确性研究纳入2011-2014年转诊至渥太华大学行羟氯喹或氯喹视网膜病变筛查的63例患者(120眼),评估多焦视网膜电图(mfERG)作为筛查试验的价值。以2016年美国眼科学会推荐定义毒性,mfERG敏感度为1.00(95%CI 0.79-1.00),特异度为0.78(95%CI 0.69-0.85),环2振幅表现最佳(AUC 0.97,95%CI 0.94-1.00),且随累积剂量和日剂量线性下降。

要点

  • mfERG对氯喹/羟氯喹视网膜毒性敏感度为1.00(95%CI 0.79-1.00),特异度为0.78(95%CI 0.69-0.85)。
  • 环2振幅在各参数中表现最佳,AUC为0.97(95%CI 0.94-1.00)。
  • 环2振幅随累积剂量和日剂量增加呈线性下降。

核心结论

  • 旁中心凹mfERG振幅降低的高敏感度及其与累积剂量和日剂量的关系,说明客观功能检查具有重要作用。
  • 较高的假阳性率提示可能存在一个生理功能障碍可被mfERG客观检测到、而尚未出现谱域光学相干断层扫描结构改变的潜在时期。

研究设计与样本

  • 诊断准确性研究,纳入2011-2014年转诊至渥太华大学行羟氯喹或氯喹视网膜病变筛查的患者。
  • 共纳入63例患者(47例女性,16例男性),120眼。
  • 排除弱视、高度近视或远视、合并视网膜疾病或既往手术的患者。
  • 患者接受10-2自动视野、谱域光学相干断层扫描和mfERG检查。
  • 旁中心凹环振幅或环比值异常视为mfERG阳性结果。

主要发现

  • 120眼中,16眼(13.3%)根据美国眼科学会指南存在毒性,39眼(32.5%)mfERG结果阳性。
  • mfERG敏感度为1.00(95%CI 0.79-1.00),特异度为0.78(95%CI 0.69-0.85)。
  • 环2振幅在所有参数中表现最佳,AUC为0.97(95%CI 0.94-1.00)。
  • 环2振幅随累积剂量和日剂量增加呈线性下降。

关键数值与推荐

  • 采用2016年美国眼科学会推荐提供的羟氯喹和氯喹毒性定义。
  • 旁中心凹环振幅或环比值异常判定为mfERG阳性结果。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate multifocal electroretinography (mfERG) as a screening test for detecting hydroxychloroquine and chloroquine toxicity. DESIGN: Diagnostic accuracy study. METHODS: Patients referred to the University of Ottawa for hydroxychloroquine or chloroquine retinopathy screening during 2011-2014 underwent 10-2 automated visual field, spectral domain optical coherence tomography, and mfERG testing. Patients with amblyopia, high myopia or hyperopia, coexisting retinal disease, or prior surgery were excluded. Abnormalities in parafoveal ring amplitudes or ring ratios were considered a positive mfERG result. We used the definition for hydroxychloroquine and chloroquine toxicity provided by the 2016 American Academy of Ophthalmology recommendations. Area under the curve (AUC) for each mfERG parameter and the sensitivity and specificity of mfERG were calculated. Logistic regression was used to model the effect of covariates in receiver operating characteristic (ROC) analyses. RESULTS: In total, 63 patients (47 female, 16 male) were included. Of 120 eyes, 16 (13.3%) had toxicity according to the American Academy of Ophthalmology guidelines, and 39 (32.5%) had positive mfERG findings. mfERG was found to have a sensitivity of 1.00 (95% CI 0.79-1.00) and a specificity of 0.78 (95% CI 0.69-0.85). Ring 2 amplitude had the best performance among all parameters (AUC 0.97, 95% CI 0.94-1.00). Ring 2 amplitude decreased linearly with increasing cumulative dose and daily dose. CONCLUSIONS: The high sensitivity of parafoveal depression on mfERG and its relationship to cumulative and daily dose illustrates an important role for objective functional testing. The high false-positive rate suggests a potential period where physiologic dysfunction is detected objectively on mfERG before structural change on spectral domain optical coherence tomography.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Tsang AC, Ahmadi S, Hamilton J, et al. The Diagnostic Utility of Multifocal Electroretinography in Detecting Chloroquine and Hydroxychloroquine Retinal Toxicity. Am J Ophthalmol. 2019. PMID: 31078540. doi:10.1016/j.ajo.2019.04.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。