前囊切开技术比较:连续环形撕囊、飞秒激光辅助囊切开与选择性激光囊切开
在60只供体尸眼上比较手动连续环形撕囊(CCC)、飞秒激光辅助囊切开(FLACS)与选择性激光囊切开(SLC)的前囊切开边缘抗撕裂强度。SLC断裂强度为277±38 mN,是CCC(190±37 mN)的1.46倍;CCC(186±37 mN)是FLACS(145±35 mN)的1.28倍(P<0.001)。SLC边缘扫描电镜显示前缘卷曲及胶原改变。
要点
- SLC断裂强度277±38 mN,为CCC(190±37 mN)的1.46倍。
- CCC断裂强度186±37 mN,为FLACS(145±35 mN)的1.28倍(P<0.001)。
- SLC囊切开边缘扫描电镜见前缘卷曲及胶原改变。
核心结论
- SLC囊切开边缘强度显著强于CCC,两者均显著强于FLACS,相对强度可由各囊切开类型的扫描电镜表现解释。
研究设计与样本
- 三臂配对供体人眼研究,采用60只供体眼(30名供者),每对配对眼分别接受CCC、Victus飞秒激光(Bausch & Lomb)或CAPSULaser(Excel-Lens)囊切开。
- 三个两两比较组各含10对眼:组1为SLC眼与对侧CCC眼比较,组2为CCC眼与对侧FLACS眼比较,组3为FLACS眼与对侧SLC眼比较。
- 采用shoe-tree法对囊切开边缘施加载荷,Instron拉伸应力仪测量扩张度及引发囊膜破裂的阈值载荷,并回顾囊膜边缘扫描电镜(SEM)表现。
主要发现
- 前囊切开在外部载荷下表现为非线性弹性(弹性体)系统。
- SLC断裂强度277±38 mN vs CCC 190±37 mN,SLC为CCC的1.46倍。
- CCC断裂强度186±37 mN vs FLACS 145±35 mN(P<0.001),CCC为FLACS的1.28倍。
- 统计分析采用Wilcoxon配对符号秩检验,并遵循CONSORT指南。
- SLC囊膜边缘SEM显示前缘卷曲及胶原改变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the anterior capsulotomy edge tear strength created by manual continuous curvilinear capsulorhexis (CCC), femtosecond laser-assisted capsulotomy (FLACS), and selective laser capsulotomy (SLC). SETTING: Singapore National Eye Centre, Singapore and Excel-Lens, Livermore, California, USA. DESIGN: Three armed study in paired human eyes. METHODS: Capsulotomies were performed in 60 cadaver eyes of 30 donors using CCC, Victus Femtosecond Laser, (Bausch & Lomb, Rochester, New York, USA) or CAPSULaser, (Excel-Lens, Los Gatos, California, USA). Three pairwise study groups each involved 10 pairs of eyes. Study group 1: SLC eyes compared with fellow eyes with CCC. Study group 2: CCC eyes compared with fellow eyes with FLACS. Study group 3: FLACS eyes compared with fellow eyes with SLC.A shoe-tree method was used to apply load to the capsulotomy edge, and Instron tensile stress instrument measured distension and threshold load applied to initiate capsule fracture. Relative fracture strengths and distension of CCC, FLACS and SLC were determined. Scanning electron microscopy (SEM) of capsule edges were reviewed RESULTS: Anterior capsulotomies behave as non-linear elastic (elastomeric) systems when exposed to an external load. The pairwise study demonstrated that the SLC fracture strength was superior to that of CCC by a factor of 1.46-fold with SLC 277±38 mN versus CCC with 190±37 mN. Furthermore, CCC fracture strength was superior to that of FLACS by a factor of 1.28-fold with CCC 186 + 37 mN versus FLACS 145 ± 35 mN (p < 0.001). This was determined by statistical analysis utilising the Wilcoxon matched-pairs signed-ranks test and in accordance with the Consolidated Standards of Reporting Trials guidelines. The capsule edge of SLC on SEM demonstrated a rolled over edge anteriorly and an alteration of collagen. CONCLUSIONS: The strength of the capsulotomy edge for SLC was significantly stronger than that of CCC which and both were significantly stronger than FLACS. The relative strengths can be explained by SEM of each type of capsulotomy.
引用
- Daya S, Chee SP, Ti SE, et al. Comparison of anterior capsulotomy techniques: continuous curvilinear capsulorhexis, femtosecond laser-assisted capsulotomy and selective laser capsulotomy. Br J Ophthalmol. 2019. PMID: 30948356. doi:10.1136/bjophthalmol-2018-313421
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。