屈光性激光辅助白内障手术与常规手动手术:3144只眼疗效与安全性比较
该回顾性连续干预性比较病例系列纳入3144只眼,1580只行常规手动白内障手术(MCS),1564只行屈光性飞秒激光辅助白内障手术(ReLACS)。总体ReLACS手术时间更短、术后黄斑囊样水肿更少、平均绝对球面误差更小,但后囊膜破裂率、总体术后并发症及最终最佳矫正视力无差异;在833只较困难病例亚组中ReLACS多项屈光结局更优。
要点
- 总体ReLACS较MCS手术时间更短(7.7±0.1分钟 vs 6.8±0.1分钟,P<0.001)。
- 总体ReLACS术后黄斑囊样水肿更少(OR=0.36,95%CI 0.14-0.91,P=0.031)。
- 较困难病例亚组中ReLACS的BCVA改善>0.1 logMAR可能性更高(OR=1.80,95%CI 1.15-2.74,P=0.01)。
核心结论
- 总体而言,结果支持ReLACS与MCS的结局相似。
- 结果显示出在治疗较困难眼时ReLACS较MCS获益更明显的趋势。
研究设计与样本
- 回顾性、连续、干预性比较病例系列,共纳入3144只连续眼。
- 1580只眼接受常规手动白内障手术(MCS),1564只眼接受屈光性飞秒激光辅助白内障手术(ReLACS)。
- 研究地点为加拿大安大略省Vaughan的Uptown Surgical Centre。
主要发现
- 总体手术时间MCS为7.7±0.1分钟 vs ReLACS为6.8±0.1分钟(P<0.001)。
- 总体术后黄斑囊样水肿ReLACS较MCS更少(OR=0.36,95%CI 0.14-0.91,P=0.031)。
- 总体平均绝对球面误差MCS为0.60±0.02 D vs ReLACS为0.54±0.02 D(P=0.02)。
- 后囊膜破裂率(P=0.918)、总体术后并发症(P=0.088)及最终最佳矫正视力(P=0.881)无差异。
- 较困难病例亚组(n=833)中,ReLACS较MCS:BCVA改善>0.1 logMAR的可能性更高(OR=1.80,95%CI 1.15-2.74,P=0.01);平均绝对球面误差MCS为0.73±0.3 D vs ReLACS为0.60±0.27 D(P=0.04);平均绝对球面误差在0.5 D以内的可能性更高(OR=1.61,95%CI 1.11-2.33,P=0.012)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To report on outcomes of the efficacy and safety in 1 of the largest series of eyes undergoing either conventional manual cataract surgery (MCS) or refractive femtosecond laser-assisted cataract surgery (ReLACS). DESIGN: Retrospective, consecutive, interventional comparative case series. METHODS: This study included 3144 consecutive eyes, of which 1580 were treated via MCS, and 1564 were treated via ReLACS at Uptown Surgical Centre in Vaughan, Ontario, Canada. Preoperative characteristics, best corrected visual acuity (BCVA), mean absolute spherical error (MAE), rates of intraoperative posterior capsular rupture, and postoperative complications were evaluated. RESULTS: Across all eyes, ReLACS was superior to MCS for reducing surgical time (MCS: 7.7 ± 0.1 min vs ReLACS: 6.8 ± 0.1 min, P < 0.001); was less commonly associated with postoperative cystoid macular edema (OR = 0.36, 95% CI: 0.14-0.91, P = 0.031) and more commonly reduced MAE (MCS: 0.60 ± 0.02 diopters (D) vs ReLACS: 0.54 ± 0.02 D, P = 0.02). There were no differences in rates of posterior capsular rupture (P = 0.918), overall postoperative complications (P = 0.088) or final BCVA (P = 0.881). When analyzing a subgroup of more difficult cases (n = 833), ReLACS was superior to MCS for: 1) being more likely to yield an improvement of more than 0.1 logarithm of the minimum angle of resolution BCVA (OR = 1.80, 95% CI: 1.15-2.74, P = 0.01); 2) reducing MAE (MCS: 0.73 ± 0.3 D vs ReLACS: 0.60 ± 0.27 D, P = 0.04); and 3) being more likely to yield an MAE within 0.5 D (OR = 1.61, 95% CI: 1.11-2.33, P = 0.012). CONCLUSIONS: Across all eyes, our results support that ReLACS and MCS yield similar outcomes. However, our results show trends toward a more pronounced benefit of ReLACS compared to MCS when treating more difficult eyes.
引用
- Nithianandan H, Jegatheeswaran V, Dalal V, et al. Refractive Laser-Assisted Cataract Surgery versus Conventional Manual Surgery: Comparing Efficacy and Safety in 3144 Eyes. Am J Ophthalmol. 2019. PMID: 31009596. doi:10.1016/j.ajo.2019.04.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。