伴与不伴网状假性玻璃膜疣的中期年龄相关性黄斑变性患者视杆细胞功能的纵向评估
本研究纵向评估中期年龄相关性黄斑变性(AMD)伴网状假性玻璃膜疣(RPD)与不伴RPD患者的视杆细胞功能。在基线和12个月随访时于中央12°黄斑区14个位点行暗适应视网膜敏感性检测。结果显示RPD组基线与12个月时静态和动态视杆功能最差;AMD组12个月内静态功能改善,但12°偏心度处视杆恢复速率下降。
要点
- RPD组基线与12个月时静态和动态视杆功能均显著差于AMD组和对照组。
- AMD组12个月内静态视杆功能改善(P ≤ 0.04),对照组和RPD组无变化(P ≥ 0.17)。
- AMD组12°偏心度处视杆恢复速率下降(P = 0.02),对照组和RPD组保持稳定。
核心结论
- AMD组在12个月随访时于12°偏心度处检测到视杆恢复速率(RRR)下降。
- 评估视杆功能变化需要在包括周边黄斑在内的多个位点进行测试。
研究设计与样本
- 纵向观察性研究,纳入23例对照、12例AMD和13例RPD受试者,在基线和12个月访视时进行暗适应视网膜敏感性检测。
主要发现
- 基线时RPD组静态和动态视杆功能显著差于AMD组和对照组,AMD组静态功能与对照组相似。
- 对照组中央12°静态和动态功能一致,疾病组在4°偏心度处受损最重(与12°相比)。
- 12个月内AMD组静态功能改善(P ≤ 0.04),对照组和RPD组无变化(P ≥ 0.17)。
- 对照组和RPD组RRR保持稳定,AMD组仅12°处恶化(P = 0.02)。
- 视杆拦截时间(RIT)在AMD组(P = 0.75)和RPD组(P = 0.71)稳定,对照组改善(P = 0.002)。
关键数值与推荐
- 静态视杆功能通过505 nm和625 nm刺激的位点敏感性差异评估,动态功能通过RIT和RRR评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate rod function longitudinally in intermediate age-related macular degeneration subjects with reticular pseudodrusen (RPD) and without RPD (AMD). METHODS: Retinal sensitivities (505 and 625 nm) during dark adaptation, at 14 locations within the central 12° macula were obtained after photobleaching at baseline and 12-month visits. Pointwise sensitivity differences between both stimuli were used to assess static rod function, while rod intercept time (RIT) and rod recovery rate (RRR) were used to evaluate dynamic function. Changes in function over time were compared between groups. RESULTS: A total of 23 controls, 12 AMD, and 13 RPD cases were followed-up. At baseline, the RPD group had significantly worst static and dynamic rod function compared to AMD and control groups. Static function in AMD was similar to controls. Static and dynamic function across the central 12° was consistent in controls; however, it was most impaired at 4° compared to 12° eccentricity in disease groups. Over 12 months, no AMD cases progressed clinically and static function in AMD improved (P ≤ 0.04), but remained unchanged in control and RPD groups (P ≥ 0.17). The RRR for control and RPD groups remained stable, while the AMD group deteriorated, but only at 12° (P = 0.02). The RIT was stable in AMD (P = 0.75) and RPD (P = 0.71) groups but improved in the control group (P = 0.002). CONCLUSIONS: A decrease in RRR was detected over 12 months at 12° eccentricity in the AMD group. Evaluating changes in rod function requires testing at multiple locations including the peripheral macula.
引用
- Tan RS, Guymer RH, Aung KZ, et al. Longitudinal Assessment of Rod Function in Intermediate Age-Related Macular Degeneration With and Without Reticular Pseudodrusen. Invest Ophthalmol Vis Sci. 2019. PMID: 30994862. doi:10.1167/iovs.18-26385
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。