中国与白人成人眼生物测量及房水动力学差异
本研究比较健康中国与白人年轻及年长成人眼生物测量与房水动力学差异。白人前房容积更大、眼压更低,年轻白人中央角膜更薄、葡萄膜巩膜流出率更快,年长白人房水生成率更慢,这些差异可能解释其房角更宽及青光眼风险更低。
要点
- 白人前房容积更大,可能对应更宽房角。
- 白人眼压更低,房水生成率更慢且葡萄膜巩膜流出率更快。
- 年轻白人中央角膜更薄,年长白人房水生成率更慢。
核心结论
- 白人前房容积更大可能贡献更宽房角,房水生成率更慢伴葡萄膜巩膜流出率更快可能贡献更低眼压和更低青光眼总体风险。
研究设计与样本
- 比较两项设计相同的独立研究数据,年轻组为20-30岁(中国32人、白人39人),年长组为>50岁(中国37人、白人46人),采用广义估计方程进行组间比较。
主要发现
- 年轻白人较同龄中国成人中央角膜薄29.27 µm(p<0.001)、眼压低2.33 mm Hg(p<0.001)、前房容积大28.78 µL(p<0.001)、葡萄膜巩膜流出率快0.82 µL/min(p<0.001)。
- 年长白人较同龄中国成人房水生成率慢0.28 µL/min(p=0.042)、眼压低1.97 mm Hg(p<0.001)、前房容积大33.15 µL(p<0.001)。
- 按种族合并所有受试者,白人房水生成率慢0.22 µL/min(p=0.035)、角膜薄0.52 µm(p=0.003)、眼压低2.11 mm Hg(p<0.001)、前房容积大30.39 µL(p<0.001)、葡萄膜巩膜流出率快0.63 µL/min(p<0.001)。
临床怎么用
- 评估中国成人青光眼风险时,应考虑其前房容积较小、眼压较高及房水动力学差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Glaucoma prevalence and subtype profile vary across different racial and ethnic groups. This study provides a comparative evaluation of differences in aqueous humour dynamics (AHD) and ocular biometrics in healthy Chinese and Caucasian adults of two different age groups. METHODS: Data from two independent studies with identical designs were compared. Cohorts included young adults (20-30 years old, 32 Chinese and 39 Caucasians) and older adults (>50 years old, 37 Chinese and 46 Caucasians). Parameters of AHD and ocular biometrics were evaluated. Group comparisons were made by generalised estimating equation methods. RESULTS: Differences in young adult Caucasians compared with similarly aged Chinese were thinner central cornea (-29.27 µm, p<0.001), lower intraocular pressure (IOP) (-2.33 mm Hg, p<0.001), larger anterior chamber volume (ACV) (28.78 µL, p<0.001) and faster uveoscleral outflow rate (Fu) (0.82 µL/min, p<0.001). Differences in older adult Caucasians compared with similarly aged Chinese were slower aqueous flow rate (Fa) (-0.28 µL/min, p=0.042), lower IOP (-1.97 mm Hg, p<0.001) and larger ACV (33.15 µL, p<0.001). Considering all subjects together by race, Caucasian subjects had slower Fa (-0.22 µL/min, p=0.035), thinner corneas (-0.52 µm, p=0.003), lower IOP (-2.11 mm Hg, p<0.001), higher ACV (30.39 µL, p<0.001) and faster Fu (0.63 µL/min, p<0.001). CONCLUSION: Differences in AHD and biometrics between Caucasian and Chinese adults include larger ACVs which may contribute to the wider angles reported in Caucasians, and slower Fa rates coupled with faster Fu rates which may contribute to their lower IOP and lower overall risk of glaucoma.
引用
- Fan S, Guo T, Chen B, et al. Differences in ocular biometrics and aqueous humour dynamics between Chinese and Caucasian adults. Br J Ophthalmol. 2019. PMID: 30894342. doi:10.1136/bjophthalmol-2018-313132
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。