剥脱性青光眼与原发性开角型青光眼的黄斑血管密度及中心凹无血管区参数比较
采用光学相干断层扫描血管成像(OCTA)测量黄斑血管密度与中心凹无血管区(FAZ)参数。结果显示XFG组浅层毛细血管丛(SCP)在多个象限及全部8个同心环的血管密度显著低于POAG组,而FAZ参数两组间无显著差异。
要点
- 视野缺损程度相当时,XFG的黄斑血管密度低于POAG。
- XFG组SCP密度在上方与鼻侧象限显著降低。
- 两组FAZ参数未见显著差异。
核心结论
- 在中心视野缺损程度相当的样本中,XFG的黄斑血管密度总体上低于POAG,FAZ参数两组间无显著差异。
研究设计与样本
- 以中心凹为中心的3×3 mm OCTA扫描,内置软件测量黄斑各象限SCP血管密度,自定义软件生成全层图像并手动勾画FAZ、去除大血管。
主要发现
- SCP密度XFG低于POAG:上方象限平均差(MD)=-4.32,95%CI=-7.02,-1.61,P=0.003;鼻侧象限MD=-3.00,95%CI=05.22,-0.77,P=0.010。
- 同心环方法显示XFG组全部8个环的SCP血管密度均显著低于POAG组。
- 全层分析中除最初200 μm环外,XFG组其余各环密度均显著更低;FAZ参数两组间无显著差异。
临床怎么用
- 在视野缺损相近的XFG与POAG患者中,可关注OCTA所示黄斑血管密度差异,尤其是上方与鼻侧象限及多个同心环区域。
局限性
- 原文为横断面设计且样本量有限,作者指出需进一步研究验证结果的一致性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study was to explore macula vessel density and foveal avascular zone (FAZ) parameters in exfoliation glaucoma (XFG) compared to primary open-angle glaucoma (POAG) using optical coherence tomography angiography (OCTA). METHODS: This was a cross-sectional observational study. Twenty-six XFG and 28 POAG patients with comparable visual field defects on Humphrey 24-2 and 10-2 perimetries were recruited. OCTA scans (3 × 3 mm) centered on the fovea were obtained. Built-in software was used to measure superficial capillary plexus (SCP) vessel density at different quadrants of the macula. Custom software was then used to create a full-thickness image. The FAZ was manually delineated, and large vessels were removed. Vessel density in eight concentric rings with increments of 200-μm diameters from the delineated FAZ was measured. FAZ parameters were calculated using the custom software. RESULTS: SCP density was significantly lower in the superior (mean difference [MD] = -4.32, 95% confidence interval [CI] = -7.02, -1.61, P = 0.003) and nasal (MD = -3.00, 95% CI = 05.22, -0.77, P = 0.010) quadrants in XFG versus POAG. SCP vessel density using the concentric ring approach revealed significantly decreased values at all eight rings in XFG versus POAG. In the full-thickness analysis, density was significantly less in the XFG group in all rings except the initial 200 μm. No significant differences existed in FAZ parameters between the groups. CONCLUSIONS: Despite the presence of comparable central visual field defects, the macula vessel density was predominately lower in XFG compared with POAG in our sample of patients. Further studies are warranted to investigate the consistency of our results.
引用
- Philip S, Najafi A, Tantraworasin A, et al. Macula Vessel Density and Foveal Avascular Zone Parameters in Exfoliation Glaucoma Compared to Primary Open-Angle Glaucoma. Invest Ophthalmol Vis Sci. 2019. PMID: 30924849. doi:10.1167/iovs.18-25986
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。