评估新生血管性年龄相关性黄斑变性大型观察性登记数据库的准确性
本研究审计了Fight Retinal Blindness!数据库中245只随机抽样的眼(来自189名患者、3356次就诊、11名医生),将性别、出生年份、既往治疗、治疗和视力与临床记录核对。总体错误率为3.5%(95%CI 3.1-3.9),视力错误率为5.1%(95%CI 4.2-5.9),各字段一致性良好至优秀(κ或ICC≥0.75),就诊阳性预测值99%、阴性预测值89%,漏录就诊比例为10.2%。结论认为该数据库准确性良好(>95%),但漏录就诊比例较高。
要点
- Fight Retinal Blindness!数据库总体错误率3.5%,视力错误率5.1%,各字段一致性良好至优秀。
- 就诊阳性预测值99%、阴性预测值89%,但漏录就诊比例达10.2%。
- 漏录就诊比例高可能与回顾性数据录入负担大或患者更换医生有关。
核心结论
- Fight Retinal Blindness!数据库准确性良好(>95%),但漏录就诊比例较高(10.2%)。
研究设计与样本
- 审计245只随机抽样的眼,来自189名患者、3356次就诊、11名医生,将性别、出生年份、既往治疗、治疗和视力与临床记录核对。
- 计算错误率、漏录就诊比例、Cohen's kappa和组内相关系数一致性以及阳性和阴性预测值。
- 视力错误定义为绝对差异≥5个字母。
主要发现
- 总体错误率为3.5%(95%CI 3.1-3.9)。
- 视力错误率为5.1%(95%CI 4.2-5.9),其余字段错误率<5%。
- 各字段一致性良好至优秀(κ或ICC≥0.75)。
- 就诊阳性预测值为99%,阴性预测值为89%。
- 漏录就诊比例为10.2%。
关键数值与推荐
- 视力错误定义为绝对差异≥5个字母。
- 一致性良好至优秀定义为κ或ICC≥0.75。
临床怎么用
- 该数据库可用于追踪新生血管性年龄相关性黄斑变性真实世界治疗结局,准确性良好。
- 需注意漏录就诊比例较高(10.2%),解读结局时需考虑此局限性。
局限性
- 漏录就诊比例高,可能由于回顾性数据录入负担大或患者更换医生所致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the accuracy of an observational database that tracks real-world treatment outcomes for neovascular age-related macular degeneration. METHODS: We audited 245 randomly sampled eyes from 189 patients with 3,356 visits from 11 doctors in the Fight Retinal Blindness! DATABASE: Sex, birth year, previous treatments received, treatment, and visual acuity were validated against the clinical notes. Error rates, the proportion of missed visits (the number of visits present in the patient record but not entered into Fight Retinal Blindness!), the level of agreement using Cohen's kappa (κ) and intraclass correlation coefficients, and positive and negative predictive values were calculated. A visual acuity error was defined as an absolute difference of ≥5 letters. RESULTS: The overall error rate was 3.5% (95% confidence interval: 3.1-3.9). The error rate for visual acuity was 5.1% (95% confidence interval: 4.2-5.9) and <5% for the remaining fields. The level of agreement for each field ranged from good to excellent (κ or intraclass correlation ≥ 0.75). The positive predictive value and negative predictive value for visits were 99% and 89%, respectively. The proportion of missed visits was 10.2%. CONCLUSION: Accuracy of the Fight Retinal Blindness! database was good (>95%). The rate of missed visits was high, possibly due to the high burden of retrospective data entry or patients switching practitioners during treatment.
引用
- Nguyen V, Leung KFC, Nguyen CL, et al. ASSESSING THE ACCURACY OF A LARGE OBSERVATIONAL REGISTRY OF NEOVASCULAR AGE-RELATED MACULAR DEGENERATION. Retina. 2020. PMID: 30821728. doi:10.1097/IAE.0000000000002485
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。