角膜生物力学特性对SMILE术中不透明气泡层的影响
本研究为巢式病例对照研究,纳入71例(129眼)行SMILE的患者,比较OBL组(31眼)与非OBL组(98眼)的角膜生物力学参数。结果显示OBL组中央角膜厚度、残余基质厚度及角膜刚性参数SP较大,Logistics回归中SP的OR值为1.04(95%CI 1.01-1.07,P=0.005)。结论认为较厚角膜、较厚残余基质及较硬角膜可能增加OBL发生风险。
要点
- OBL组中央角膜厚度(572±29 μm)和残余基质厚度(356±31 μm)显著大于非OBL组。
- OBL组角膜刚性参数SP(108.85±13.77)显著高于非OBL组(100.19±14.13)。
- Logistics回归中SP的OR为1.04(95%CI 1.01-1.07,P=0.005),调整后OR为1.01(95%CI 1.00-1.05,P=0.426)。
核心结论
- OBL发生受多种角膜生物力学因素影响,较厚CCT、较厚RST及较硬角膜可能增加OBL风险。
研究设计与样本
- 巢式病例对照研究,纳入2017年6至8月行SMILE患者71例(129眼),OBL组20例(31眼),非OBL组51例(98眼)。
- 通过Pentacam HR和Corvis ST获取角膜参数,采用独立样本t检验和多元Logistics回归分析。
主要发现
- OBL组与非OBL组SE分别为(-4.64±1.33)D和(-5.78±1.61)D,差异有统计学意义(t=3.58,P<0.05)。
- OBL组与非OBL组CCT分别为(572±29)μm和(550±32)μm,RST分别为(356±31)μm和(325±36)μm,LT分别为(96±23)μm和(115±25)μm,差异均有统计学意义(P<0.05)。
- 两组间A1 DefA、HC DefA、HC DefArea、DAmax、DefAmax及SP差异均有统计学意义(P<0.05)。
关键数值与推荐
- SP在基本模型中的OR为1.04(95%CI 1.01-1.07,P=0.005),调整模型中OR为1.01(95%CI 1.00-1.05,P=0.426)。
临床怎么用
- 术前评估角膜生物力学特性(如SP、CCT、RST)有助于预判SMILE术中OBL发生风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To investigate the influence of corneal biomechanical properties on opaque bubble layer (OBL) in small incision lenticule extraction (SMILE). Methods: In this nested case control study, 20 patients (31 eyes) were enrolled in OBL group, while 51 patients (98 eyes) were included in non-OBL group. The parameters were obtained by Pentacam HR and Corvis ST examinations. Independent t test was used to analyze the difference of corneal biomechanical parameters between the two groups and multivariable logistics regression was applied to analysis the influence of corneal biomechanical properties on OBL. Results: This study enrolled 129 eyes in 71 cases including 30 males and 41 females, with a mean age of (22.50±5.18) years old. It has shown that the spherical equivalent (SE) [(-4.64±1.33) and (-5.78±1.61) D], central corneal thickness (CCT) [(572±29) and (550±32)μm], residual stromal thickness (RST)[(356±31) and (325±36 μm)], and lenticule thickness (LT) [(96±23) and (115±25) μm] were significantly different between OBL group and non-OBL group (t=3.58, -3.43, -5.68 and 3.64, respectively, P<0.05). There were significant differences in deflection amplitude at the first applanation and highest concavity (A1 DefA and HC DefA), deflection area at the highest concavity (HC DefArea), maximum deformation amplitude (DAmax), maximum deflection amplitude (DefAmax) and stiff parameter (SP) (108.85±13.77 and 100.19±14.13) between the two groups (t=-2.75, 2.41, 3.62, 4.09, 2.22 and -2.99, respectively, P<0.05). The OR and 95% confidence interval of SP in crude and adjusted logistics models were 1.04, (1.01-1.07) (P=0.005), and 1.01, (1.00-1.05) (P=0.426), respectively. Conclusions: The occurrence of OBL could be influenced by various corneal biomechanical factors. The thicker CCT, thicker RST and the stiffer cornea may increase the risk for the occurrence of OBL. Fully acknowledgement on the relationship between corneal biomechanics and surgical outcomes and evaluation of the occurrence of OBL in SMILE surgery is of great importance for improving the safety and predictability of SMILE. (Chin J Ophthalmol, 2019, 55:115-121). 目的: 探讨飞秒激光小切口角膜基质透镜取出术(SMILE)术中不透明气泡层(OBL)的产生及其可能的生物力学影响因素进行分析。 方法: 巢式病例对照研究。入选2017年6至8月行SMILE的患者,术中出现OBL者为OBL组,与其同日行SMILE但无其他术中并发症者为无OBL组。通过术前Pentacam眼前节分析系统及Corvis ST检查获取分析参数。独立样本t检验及多元Logistics回归模型分别用于分析两组之间生物力学参数的差异及与OBL发生可能相关的生物力学影响因素。 结果: 本研究共纳入71例(129只眼)患者,年龄为(22.50±5.18)岁,男性30例,女性41例,其中OBL组20例(31只眼),无OBL组51例(98只眼)。结果显示OBL组与无OBL组的等效球镜度数(SE)[(-4.64±1.33)和(-5.78±1.61)D]、中央角膜厚度(CCT)[(572±29)和(550±32)μm]、残余基质厚度(RST)[(356±31)和(325±36)μm]及透镜厚度(LT)[(96±23)和(115±25)μm]差异均有统计学意义(t=3.58,-3.43,-5.68,3.64;P<0.05);两组之间的第一次压平时的偏移幅度(A1 DefA)、最大压陷时的偏移幅度(HC DefA)、最大压陷时的偏移面积(HC DefArea)、最大形变幅度(DAmax)、最大偏移幅度(DefAmax)、角膜刚性参数(SP)(108.85±13.77和100.19±14.13)差异均有统计学意义(t=-2.75,2.41,3.62,4.09,2.22,-2.99;P<0.05)。Logistics回归基本模型和调整模型中,SP的OR值为1.04(95%可信区间1.01~1.07)(P=0.005)、1.01(95%可信区间1.00~1.05)(P=0.426)。 结论: 影响OBL发生的角膜生物力学因素是多方面的,角膜厚度及残余基质床厚度较厚,SP较大均可能增加OBL发生的可能性。充分了解角膜生物力学特性对于手术效果的影响,同时评估术中OBL的发生,对于提高SMILE的安全性和预测性具有重要意义。(中华眼科杂志,2019,55:115-121).