药物与手术治疗青光眼患者眼压波动的接触镜传感器比较
前瞻性非随机病例系列研究,用接触镜传感器(CLS)对77例患者91眼进行24小时眼压相关波动监测,其中药物组59眼、手术组32眼。
核心结论
- 药物治疗的青光眼眼压相关波动幅度大于手术治疗者。
- 手术组夜间acrophase缺失的比例显著高于药物组。
研究设计与样本
- 前瞻性、非随机病例系列研究。
- 共纳入77例患者91眼,药物组59眼,手术组32眼(开角型青光眼,既往接受过青光眼手术)。
- 使用接触镜传感器(CLS)进行24小时眼压相关波动监测。
关键数值与推荐
- 主要结局指标为CLS信号幅度及夜间acrophase是否存在。
- 幅度以mV eq表示,并记录每例患者眼压相关最大值和最小值。
临床怎么用
- CLS可提供24小时眼压相关波动信息,辅助评估药物与手术治疗青光眼患者的波动差异。
- 手术组夜间acrophase缺失更常见,提示术后眼压节律可能改变。
局限性
- 非随机设计,药物组与手术组基线特征可能不均衡。
- 样本量有限(91眼),结果需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare fluctuations in intraocular pressure (IOP) in medically vs surgically treated glaucoma patients. DESIGN: Prospective, nonrandomized case series. METHODS: IOP-related fluctuations were measured for 24 hours using a contact lens sensor (CLS). SUBJECTS: We performed monitoring with CLS in 91 eyes of 77 patients; 59 eyes were receiving ocular hypotensive medication and had no previous history of glaucoma surgery (medical group), while 32 eyes with open-angle glaucoma (OAG) had previously undergone glaucoma surgery (surgical group). MAIN OUTCOME MEASURES: The amplitude, expressed as an indicator of the IOP-related fluctuation, and the presence of a nocturnal acrophase. We also identified maximum and minimum IOP-related values for each patient. RESULTS: The mean (standard deviation) amplitude of IOP-related CLS signal in the group of surgically treated eyes was 100 (41) mV eq, while in the medically treated group it was 131 (69) mV eq (difference: P = .010). We found that 42.9% of the surgically treated but only 13.8% of the medically treated glaucoma group exhibited an absence of nocturnal acrophase (difference: P = .011). The maximum and minimum IOP-related values for the medical group were statistically higher than the surgical group (P = .001 and P = .006, respectively). CONCLUSIONS: IOP-related fluctuations were larger in eyes with medically treated glaucoma than in those with surgically treated glaucoma. A significantly larger fraction of the surgical group exhibited an absence of nocturnal acrophase compared to the medically treated group.
引用
- Muniesa MJ, Ezpeleta J, Benítez I, et al. Fluctuations of the Intraocular Pressure in Medically Versus Surgically Treated Glaucoma Patients by a Contact Lens Sensor. Am J Ophthalmol. 2019. PMID: 30771332. doi:10.1016/j.ajo.2019.02.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。