文献速递眼底病与葡萄膜炎青光眼

眼内氧与抗氧化状态:玻璃体切除与青光眼发病机制的新见解

Intraocular Oxygen and Antioxidant Status: New Insights on the Effect of Vitrectomy and Glaucoma Pathogenesis.
PubMed 文献 · Am J Ophthalmol · 2019-02-15

这项前瞻性横断面研究纳入288只眼,按晶状体和玻璃体状态及原发性开角型青光眼分层,测量前房角与后房氧分压及房水抗坏血酸和总反应性抗氧化潜力。结果显示玻璃体切除后前房角和后房氧分压显著升高,房水抗氧化水平显著降低;玻璃体完整者中氧分压和抗氧化状态与晶状体状态或青光眼无关。

要点

  • 玻璃体切除后前房角氧分压为16.2±5.0 mmHg,高于白内障手术参照组的13.0±3.9 mmHg(P=.0171)。
  • 玻璃体切除后后房氧分压为7.6±3.1 mmHg,高于参照组的3.9±2.7 mmHg(P<.0001)。
  • 玻璃体切除后房水抗坏血酸和总反应性抗氧化潜力显著降低(P=.004和P=.024)。

核心结论

  • 玻璃体切除后眼内氧分压升高和抗氧化物质耗竭提示眼内氧化-抗氧化平衡改变。
  • 前房角和后房氧分压升高与房水抗氧化水平降低相关,可能通过氧化应激损伤小梁网参与眼压升高和青光眼风险增加。

研究设计与样本

  • 前瞻性横断面研究,共纳入288只眼,按晶状体和玻璃体状态及原发性开角型青光眼存在与否分层进行统计分析。
  • 在计划青光眼和/或白内障手术开始时用光纤探针测量眼内氧分压,并采集房水标本分析抗坏血酸和总反应性抗氧化潜力。

主要发现

  • 既往行经平坦部玻璃体切除术后,前房角氧分压为16.2±5.0 mmHg,高于白内障手术参照组的13.0±3.9 mmHg(P=.0171)。
  • 玻璃体切除术后后房氧分压为7.6±3.1 mmHg,高于参照组的3.9±2.7 mmHg(P<.0001)。
  • 玻璃体切除术后房水抗坏血酸为1.1±0.4 mM,低于参照组的1.4±0.5 mM(P=.004)。
  • 玻璃体切除术后房水总反应性抗氧化潜力为403.3±116.5 Trolox单位,低于参照组的479.0±146.7 Trolox单位(P=.024)。
  • 在玻璃体完整的患者中,氧分压和抗氧化状态与晶状体状态或青光眼均无相关性。

临床怎么用

  • 玻璃体切除术后应关注眼内氧化应激增加和抗氧化储备下降,警惕眼压升高和青光眼风险。
  • 玻璃体完整者中氧分压和抗氧化状态与晶状体状态或青光眼无关,提示玻璃体状态是重要考量因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to investigate correlations of partial pressure of oxygen (pO2) in the ocular anterior segment of human eyes and aqueous humor antioxidant levels of ascorbate (AsA) and total reactive antioxidant potential (TRAP) with glaucoma and vitreous status. METHODS: This prospective, cross-sectional study stratified patients (n = 288 eyes) by lens and vitreous status and the presence of primary open-angle glaucoma for statistical analyses. Intraocular pO2 concentrations were measured using a fiberoptic probe in patients at the beginning of planned glaucoma and/or cataract surgery. Aqueous humor specimens were obtained for antioxidant analysis of AsA and TRAP. RESULTS: Following prior pars plana vitrectomy, pO2 levels were significantly higher than in the reference group of cataract surgery in the anterior chamber angle (16.2 ± 5.0 vs. 13.0 ± 3.9 mm Hg; P = .0171) and in the posterior chamber (7.6 ± 3.1 vs. 3.9 ± 2.7 mm Hg; P < .0001). AsA and TRAP levels were significantly lower (1.1 ± 0.4 vs. 1.4 ± 0.5 mM, respectively; 403.3 ±116.5 vs. 479.0 ± 146.7 Trolox units, respectively; P = .004 and P = .024, respectively) in patients after vitrectomy. In patients with an intact vitreous, neither pO2 nor antioxidant status correlated with lens status or glaucoma. CONCLUSIONS: Increased pO2 and antioxidant depletion following vitrectomy suggests an alteration of the intraocular oxidant-antioxidant balance. Our study links physiologic factors such as increased pO2 in the anterior chamber angle and the posterior chamber to decreased antioxidant levels in aqueous humor following vitrectomy. Oxidative stress/damage to the trabecular meshwork in such post-vitrectomy cases may contribute to intraocular pressure elevation and increased risk of glaucoma. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Siegfried CJ, Shui YB. Intraocular Oxygen and Antioxidant Status: New Insights on the Effect of Vitrectomy and Glaucoma Pathogenesis. Am J Ophthalmol. 2019. PMID: 30772349. doi:10.1016/j.ajo.2019.02.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。