文献速递眼底病与葡萄膜炎

扫频源与谱域OCTA在测量1型新生血管中与染料血管造影的比较

SWEPT-SOURCE AND SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY VERSUS DYE ANGIOGRAPHY IN THE MEASUREMENT OF TYPE 1 NEOVASCULARIZATION.
PubMed 文献 · Retina · 2020-01-01

ICGA测得面积显著大于两种OCTA(P=0.008),两种OCTA间无差异且一致性极好(平均差=0.2),SS-OCTA图像质量更优。

要点

  • ICGA测得1型新生血管面积大于SD-OCTA和SS-OCTA(均P=0.008)。
  • SD-OCTA与SS-OCTA间一致性极好,平均差=0.2。
  • SS-OCTA提供的新生血管图像质量优于SD-OCTA。

核心结论

  • SS-OCT或SD-OCT较ICGA能更好显示新生血管范围,可能受脉络膜通透性和染料渗漏影响。
  • OCTA测量的新生血管面积有望成为AMD随访的客观参数。

主要发现

  • ICGA测得新生血管面积高于SD-OCTA(P=0.008)和SS-OCTA(P=0.008)。
  • 两种OCTA间新生血管面积无差异,一致性的平均差为0.2。
  • ICGA与SD-OCTA配对信度最低(组内相关系数=0.786,置信区间=0.500-0.915)。
  • 分别分析3×3-mm和6×6-mm扫描时结果相似。
  • SS-OCTA的新生血管图像质量定性优于SD-OCTA。

关键数值与推荐

  • ICGA与SD-OCTA组内相关系数=0.786(置信区间=0.500-0.915)。
  • SD-OCTA与SS-OCTA平均差=0.2。

临床怎么用

  • OCTA可用于客观测量1型新生血管面积,辅助AMD随访。
  • 解读OCTA新生血管面积时需考虑其可能小于ICGA测量值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the area of Type 1 neovascularization in patients with age-related macular degeneration calculated on spectral domain optical coherence tomography angiography (SD-OCTA), swept-source OCTA, and indocyanine green angiography (ICGA). METHODS: Cross-sectional study enrolling patients with neovascular age-related macular degeneration with Type 1 neovascularization. During the same visit, ICGA (Spectralis HRA, Heidelberg, Germany), 3 × 3-mm or 6 × 6-mm SD-OCTA (CIRRUS AngioPlex model 5000; Carl Zeiss Meditec, Inc, Dublin, OH), and 3 × 3-mm or 6 × 6-mm swept-source OCTA (Plex Elite 9000; Carl Zeiss Meditec, Inc) were performed. Neovascularization areas were compared among the three instruments. The degree of consistency between measurements was investigated through the two-way mixed intraclass correlation, whereas the intermethod agreement was expressed by the Bland-Altman analysis. Mean difference and 95% confidence intervals are provided. RESULTS: Eighteen eyes of 14 white patients (10 females, 83.3%) were included in the study. The neovascularization area measured on ICGA was higher compared to that measured on both SD-OCTA (P = 0.008) and swept-source OCTA (P = 0.008), whereas no differences were found between the two OCTA. Similar results were achieved analyzing 3 × 3-mm and 6 × 6-mm scan separately. Lowest reliability resulted from the ICGA versus SD-OCTA pair (intraclass correlation = 0.786, confidence interval = 0.500-0.915). Spectral domain OCTA and swept-source OCTA exhibited an excellent agreement (mean difference = 0.2). Swept-source OCTA offered qualitatively better images of the neovascularization, compared with SD-OCTA. CONCLUSION: Better visualization of the extent of neovascularization is obtained using SS-OCT or SD-OCT compared with ICGA, which may be influenced by choroidal permeability and dye leakage. Neovascularization area on OCTA may become an objective parameter in the follow-up of age-related macular degeneration patients, along with traditional imaging techniques.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Cicinelli MV, Cavalleri M, Consorte AC, et al. SWEPT-SOURCE AND SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY VERSUS DYE ANGIOGRAPHY IN THE MEASUREMENT OF TYPE 1 NEOVASCULARIZATION. Retina. 2020. PMID: 30649078. doi:10.1097/IAE.0000000000002452

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。