分阶段植入三种近附加衍射多焦人工晶状体的双眼视功能
这项前瞻性比较病例系列纳入56例分期植入双焦人工晶状体的患者,第一眼植入+4.0 D近附加,第二眼根据术后1周结果和患者偏好选择+4.0 D(MM组)、+3.25 D(ML组)或+2.75 D(MK组)。术后3个月,MK组在0.5米处双眼裸眼视力显著优于MM组,ML和MK组在0.5米处双眼最佳矫正视力显著优于MM组,而双眼对比敏感度和立体视无显著差异。
要点
- 第二眼选择不同近附加的分期植入可改善中距离双眼视力。
- MK组0.5米双眼裸眼视力显著优于MM组(P=.003)。
- 三组间双眼对比敏感度和立体视无显著差异。
核心结论
- 分期植入不同近附加衍射多焦人工晶状体可获得更好的双眼中距离视力且不降低视功能。
研究设计与样本
- 前瞻性比较病例系列,纳入56例分期植入双焦人工晶状体患者的双眼。
- 第一眼植入+4.0 D近附加,第二眼根据术后1周结果和患者偏好选择+4.0 D(MM组)、+3.25 D(ML组)或+2.75 D(MK组)。
主要发现
- MM、ML和MK组分别包括21、18和17例患者。
- MM组0.5米平均双眼裸眼视力显著差于MK组(P=.003)。
- ML和MK组0.5米双眼最佳矫正视力显著优于MM组(P<.02)。
- MM与MK组的-2.0 D离焦曲线差异显著(P<.001)。
- 双眼对比敏感度和立体视值无显著差异。
临床怎么用
- 对侧眼根据第一眼术后结果和患者近视力偏好选择不同近附加,可能优化中距离视力而不损害对比敏感度和立体视。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the binocular visual function and depth of focus after staged implantation of diffractive multifocal intraocular lenses (MIOLs) with 3 different add powers following cataract removal. DESIGN: Prospective comparative case series. METHODS: Setting: Institutional. STUDY POPULATION: Both eyes of 56 patients that underwent staged implantation of bifocal IOLs. INTERVENTION: In the first eye, MIOLs with a +4.0-diopter (D) add power were implanted. Based on outcomes at 1 week postoperatively and patient preference for near vision, 1 of 3 near add powers-+4.0 D (group MM), +3.25 D (group ML), or +2.75 D (group MK)-was implanted in the fellow eye. MAIN OUTCOME MEASURE(S): Three months postoperatively, the binocular uncorrected and distance-corrected visual acuities (BUCVA and BDCVA, respectively) at 5.0, 1.0, 0.5, 0.4, and 0.3 meters; binocular defocus curves; contrast sensitivity; and near stereopsis were measured. RESULTS: The MM, ML, and MK groups included 21, 18, and 17 patients, respectively. The mean BUCVA in the MM group was significantly (P = .003) worse than that in the MK group at 0.5 meter. The BDCVAs at 0.5 meter in the ML and MK groups were significantly (P < .02) better than that in the MM group. The defocus curves with the -2.0 D refraction differed significantly (P < .001) between the MM and MK groups. The binocular contrast sensitivity and stereopsis values did not differ significantly. CONCLUSIONS: Staged implantation of different add powers obtained better binocular intermediate visual acuity without degradation of visual function.
引用
- Bissen-Miyajima H, Ota Y, Nakamura K, et al. Binocular Visual Function With Staged Implantation of Diffractive Multifocal Intraocular Lenses With Three Add Powers. Am J Ophthalmol. 2018. PMID: 30552894. doi:10.1016/j.ajo.2018.11.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。