文献速递眼底病与葡萄膜炎

OCT血管成像与视锥细胞成像在地图状萎缩中的应用

OCT Angiography and Cone Photoreceptor Imaging in Geographic Atrophy.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

本研究比较了年龄相关性黄斑变性(AMD)地图状萎缩(GA)患者与年龄相仿正常眼的视锥细胞间距和脉络膜毛细血管(CC)灌注。结果显示,AMD患眼GA边界外CC血流缺损显著大于正常眼,且CC血流缺损与距GA边缘距离负相关、与视锥细胞间距增加正相关;CC血流缺损范围较视锥细胞丢失更广泛。

要点

  • AMD患眼GA边界外CC血流缺损显著大于年龄相仿正常眼(P=0.024)。
  • CC血流缺损与距GA边缘距离负相关(r=-0.35),越近缺损越重。
  • 视锥细胞间距增加与CC血流缺损正相关(r=0.33),但CC缺损更广泛。

核心结论

  • 在AMD所致GA患眼中,CC低灌注与视锥细胞丢失显著相关且范围更广,提示CC灌注减少可能促进GA发展。

研究设计与样本

  • 研究纳入6例AMD患者8只眼和4只年龄相仿正常眼,采用自适应光学扫描激光检眼镜、眼底自发荧光和扫频源OCT血管成像进行成像。
  • 以FAF图像确定GA边界,分析距GA边界1°区域内CC血流缺损,并由对CC灌注设盲的评分者选择视锥 mosaic 清晰的ROI。
  • 将每个ROI的视锥细胞间距和CC血流缺损转换为Z评分,分别基于12只50-81岁正常眼和60只51-88岁正常眼的均值。

主要发现

  • 排除GA和玻璃膜疣区域后,AMD患眼CC血流缺损显著大于年龄相仿正常眼(精确置换检验,P=0.024)。
  • CC血流缺损与距GA边缘距离呈负相关(r=-0.35;95%CI,-0.53至-0.12)。
  • 视锥细胞间距增加与CC血流缺损显著正相关(r=0.33;95%CI,0.12至0.59)。
  • 视锥细胞间距增加的ROI占39%,而CC血流缺损增加的ROI占96%。

关键数值与推荐

  • CC血流缺损分析区域为距GA边界1°范围。
  • 视锥细胞间距Z评分参考12只50-81岁正常眼均值,CC血流缺损Z评分参考60只51-88岁正常眼均值。

临床怎么用

  • OCT血管成像可评估GA边界外CC灌注状态,辅助判断GA进展风险。
  • 自适应光学成像可观察视锥细胞结构改变,但CC血流缺损可能早于视锥细胞丢失。

局限性

  • 样本量小(AMD组6例8只眼,正常组4只眼),结论需更大样本验证。
  • 原文未报告纵向随访数据,无法确定因果关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare cone spacing and choriocapillaris (CC) perfusion adjacent to geographic atrophy (GA) in patients with age-related macular degeneration (AMD) and age-similar normal eyes. METHODS: Subjects were imaged using adaptive optics scanning laser ophthalmoscopy (AOSLO), fundus autofluorescence (FAF), and swept-source optical coherence tomography angiography. The GA border was identified using FAF images; CC flow void was analyzed in 1° regions extending from the GA border. A grader masked to CC perfusion selected regions of interest (ROIs) with unambiguous cone mosaics in AOSLO images. At each ROI, cone spacing and CC flow void were converted to Z-scores (standard deviations from the mean of 12 normal eyes aged 50 to 81 years for cone spacing, and 60 normal eyes age 51 to 88 years for CC flow void). RESULTS: Excluding regions of GA and drusen, CC flow void in eight eyes of six patients with AMD was significantly greater than in four age-similar normal eyes (exact permutation test, P = 0.024). CC flow void was negatively correlated with distance from the GA margin (r = -0.35; 95% confidence interval [CI], -0.53 to -0.12). Increased cone spacing was significantly correlated with CC flow void (r = 0.33; 95% CI, 0.12 to 0.59). Cone spacing was increased in 39% of ROIs, while CC flow void was increased in 96% of ROIs. CONCLUSIONS: In eyes with GA due to AMD, CC hypoperfusion was significantly correlated with, and more extensive than, cone photoreceptor loss. The results suggest that reduced CC perfusion contributes to the development of GA.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Qin J, Rinella N, Zhang Q, et al. OCT Angiography and Cone Photoreceptor Imaging in Geographic Atrophy. Invest Ophthalmol Vis Sci. 2018. PMID: 30572343. doi:10.1167/iovs.18-25032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。