文献速递小儿眼科与斜弱视神经眼科

连续闪光抑制在弱视与正常视觉中的朝向调谐与对比度依赖性

Orientation Tuning and Contrast Dependence of Continuous Flash Suppression in Amblyopia and Normal Vision.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

研究纳入9例弱视成人(平均年龄26.9±SD 4.7岁)和11例视觉正常对照(平均年龄24.8±SD 5.3岁),采用连续闪光抑制(CFS)范式结合光栅对比度增量检测任务,考察抑制的朝向调谐与对比度依赖性。结果显示对照组表现出朝向调谐的CFS(平均半高带宽35.8°±SD 21.5°)且双眼间抑制强度近乎相等;5例弱视患者表现为朝向非依赖性CFS,8例患者双眼间抑制显著不等,且增加弱视眼噪声对比度后抑制仍不平衡。结论提示异常早期视觉经验可能破坏双眼间抑制机制的发育。

要点

  • 对照组CFS呈朝向调谐(半高带宽35.8°±SD 21.5°),双眼抑制强度近乎相等。
  • 5/9弱视患者CFS无朝向特异性,8/9患者双眼抑制显著不等,无法由临床指标预测。
  • 增加弱视眼噪声对比度可抑制对侧眼,但双眼抑制不平衡持续存在。

核心结论

  • 弱视患者CFS的朝向特异性表现宽泛或缺失,且多数患者在整个对比度范围内抑制不平衡。
  • 异常早期视觉经验可能破坏双眼间抑制机制的发育。

研究设计与样本

  • 研究纳入9例弱视成人(平均年龄26.9±SD 4.7岁)和11例视觉正常对照(平均年龄24.8±SD 5.3岁)。
  • 采用CFS范式:一眼呈现10 Hz刷新的空间一维噪声以抑制另一眼,通过光栅对比度增量检测任务测量抑制强度。
  • 实验1固定噪声对比度、改变噪声与光栅的朝向差;实验2使噪声与光栅朝向相同、改变噪声对比度。

主要发现

  • 两组抑制模式均存在个体差异。
  • 实验1中对照组表现出朝向调谐的CFS(平均半高带宽35.8°±SD 21.5°),双眼抑制强度近乎相等;5例弱视患者表现为朝向非依赖性CFS。
  • 8例弱视患者双眼间抑制显著不等。
  • 实验2中增加弱视眼噪声对比度可产生对侧眼抑制,但双眼抑制仍不平衡。

临床怎么用

  • CFS范式可用于评估弱视患者双眼间抑制的朝向调谐与对比度依赖性。
  • 弱视患者CFS朝向特异性宽泛或缺失且抑制不平衡,提示临床评估需关注双眼抑制异常。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Suppression in amblyopia may be an unequal form of normal interocular suppression or a distinct pathophysiology. To explore this issue, we examined the orientation tuning and contrast dependence of continuous flash suppression (CFS) in adults with amblyopia and visually normal controls. METHODS: Nine patients (mean age, 26.9 ± SD 4.7 years) and 11 controls (mean age, 24.8 ± SD 5.3 years) participated. In the CFS paradigm, spatially one-dimensional noise refreshing at 10 Hz was displayed in one eye to induce suppression of the other eye, and suppression strength was measured by using a grating contrast increment detection task. In experiment 1, noise contrast was fixed and the orientation difference between the noise and the grating was varied. In experiment 2, noise and grating orientations were identical and noise contrast was varied. RESULTS: Suppression patterns varied in both groups. In experiment 1, controls showed consistently orientation-tuned CFS (mean half-height bandwidth, 35.8° ± SD 21.5°) with near-equal strength between eyes. Five of nine patients with amblyopia exhibited orientation-independent CFS. Eight patients had markedly unequal suppression between eyes. Experiment 2 found that increasing the noise contrast to the amblyopic eye may produce suppression of the fellow eye, but suppression remained unequal between eyes. CONCLUSIONS: Our data revealed that orientation specificity in CFS was very broad or absent in some patients with amblyopia, which could not be predicted by clinical measures. Suppression was unbalanced across the entire contrast range for most patients. This suggests that abnormal early visual experience disrupts the development of interocular suppression mechanisms.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Gao TY, Ledgeway T, Lie AL, et al. Orientation Tuning and Contrast Dependence of Continuous Flash Suppression in Amblyopia and Normal Vision. Invest Ophthalmol Vis Sci. 2018. PMID: 30452600. doi:10.1167/iovs.18-23954

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。