文献速递角膜与眼表疾病

眼睑压力与眼表疾病的关系:健康眼与干眼对比

Relationship Between Eyelid Pressure and Ocular Surface Disorders in Patients With Healthy and Dry Eyes.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

研究评估眼睑压力测量仪(blepharo-tensiometer)的可重复性,并比较健康眼与干眼的眼睑压力。结果显示该设备测量可重复,干眼的上、下眼睑压力显著高于健康眼,下眼睑压力与下方眼表染色评分及下睑擦拭上皮病变(LWE)分级显著相关。

要点

  • 眼睑压力测量仪在健康志愿者中显示可重复的测量结果。
  • 干眼患者的上、下眼睑压力显著高于健康眼。
  • 下眼睑压力与下方眼表染色及下睑LWE分级显著相关。

核心结论

  • 眼睑压力测量仪可重复测量眼睑压力,并可用于评估健康与疾病眼睑对眼表的压力。
  • 眼睑压力与眼表染色显著相关,提示眼表压力可能参与眼表疾病的发生。

研究设计与样本

  • 研究首先在健康志愿者中于3个不同日期测量眼睑压力,计算组内相关系数(ICC)以确定可重复性。
  • 随后比较健康眼与干眼的眼睑压力,并分析眼睑压力与眼表荧光素染色位置及程度的相关性。
  • 最后测量存在睑擦拭上皮病变(LWE)眼的眼睑压力。

主要发现

  • 上眼睑ICC范围为0.675至0.911,下眼睑ICC范围为0.663至0.925。
  • 干眼的上眼睑和下眼睑压力均显著高于健康眼。
  • 多变量分析显示下方眼表染色评分与下眼睑压力强相关。
  • 下眼睑压力与下睑LWE分级显著相关。

临床怎么用

  • 眼睑压力测量仪可用于临床评估眼睑对眼表的压力。
  • 对干眼患者应关注眼睑压力,尤其下眼睑压力与下方眼表染色及下睑LWE相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine whether an eyelid pressure measurement device, called a blepharo-tensiometer, can detect changes in the eyelid pressure in different types of ocular surface disorders. METHODS: First, the repeatability of the blepharo-tensiometer was determined by measuring the eyelid pressures on 3 separate days from healthy volunteers and calculating the intraclass correlation coefficients (ICCs). Second, to determine the ability of the blepharo-tensiometer to detect changes in the eyelid pressures in different types of ocular surface disorders, we compared the eyelid pressure of healthy eyes with dry eyes. Third, the correlations between the eyelid pressure and the location and magnitude of fluorescein staining of the ocular surface were analyzed. Fourth, the eyelid pressure in eyes with lid-wiper epitheliopathy (LWE) was measured. RESULTS: The ICCs ranged from 0.675 to 0.911 for the upper eyelid and 0.663 to 0.925 for the lower eyelid. The pressures of the upper and lower eyelids were significantly higher in dry eyes than in healthy eyes. The inferior ocular surface staining scores were strongly correlated with the lower eyelid pressure by multivariate analysis. The lower eyelid pressure was significantly correlated with the grade of the lower LWE. CONCLUSIONS: The blepahro-tensiometer can obtain repeatable measurements of the eyelid pressure and can be used to evaluate the pressure of the eyelids on the ocular surface in healthy and diseased eyes. The significant correlations between the eyelid pressure and the ocular surface staining suggests that the pressure on the ocular surface probably contributes to ocular surface disorders.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Yamaguchi M, Shiraishi A. Relationship Between Eyelid Pressure and Ocular Surface Disorders in Patients With Healthy and Dry Eyes. Invest Ophthalmol Vis Sci. 2018. PMID: 30481807. doi:10.1167/iovs.17-23586

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。