文献速递青光眼

筛板前视网膜层突出对最小盘沿宽度测量临床相关性的影响

Clinical relevance of protruded retinal layers in minimum rim width measurement of the optic nerve head.
PubMed 文献 · Br J Ophthalmol · 2018-11-24

该横断面研究纳入123例青光眼患者和123例年龄相仿的正常对照,通过OCT测量视盘最小盘沿宽度(MRW)并手动分割突出的视网膜层(PRL),比较调整前后MRW的诊断准确性。结果显示,PRL在正常对照中更常见(12.3% vs 7.6%),但剔除PRL并未提高MRW诊断青光眼的准确性,也未改善其与视网膜神经纤维层厚度的相关性。

要点

  • PRL在正常眼中更常见,患者中占比7.6%,对照中12.3%。
  • 剔除PRL未提高MRW诊断青光眼的准确性或敏感性。
  • 调整MRW未改善其与RNFL厚度的相关性。

核心结论

  • 剔除MRW中的突出视网膜层成分不影响其临床诊断效用。

研究设计与样本

  • 横断面研究,纳入123例青光眼患者和123例年龄相仿正常对照,进行OCT视盘24条放射扫描和RNFL环扫。

主要发现

  • 在5904条B扫描中,PRL在患者中检出448条(7.6%),对照组728条(12.3%),p<0.01。
  • PRL在两组中均最常见于颞侧区域。
  • 调整PRL后,MRW的ROC曲线下面积和95%特异性下的敏感性均未改善。
  • 调整PRL后,MRW与RNFL厚度的相关性未改善。

关键数值与推荐

  • 患者中位(IQR)视野平均偏差为-4.4(-10.3至-2.1)dB,对照组为0.0(-0.6至0.8)dB。

临床怎么用

  • 临床解读OCT测量的MRW时,无需常规剔除突出的视网膜层成分。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: Optical coherence tomography (OCT) imaging of the optic nerve head minimum rim width (MRW) has recently been shown to sometimes contain components besides extended retinal nerve fibre layer (RNFL). This study was conducted to determine whether excluding these components, termed protruded retinal layers (PRLs), from MRW increases diagnostic accuracy for detecting glaucoma. METHODS: In this cross-sectional study, we included 123 patients with glaucoma and 123 normal age-similar controls with OCT imaging of the optic nerve head (24 radial scans) and RNFL (circle scan). When present, PRLs were manually segmented, and adjusted MRW measurements were computed. We compared diagnostic accuracy of adjusted versus unadjusted MRW measurement. We also determined whether adjusted MRW correlates better with RNFL thickness compared with unadjusted MRW. RESULTS: The median (IQR) visual field mean deviation of patients and controls was -4.4 (-10.3 to -2.1) dB and 0.0 (-0.6 to 0.8) dB, respectively. In the 5904 individual B-scans, PRLs were identified less frequently in patients (448, 7.6%) compared with controls (728, 12.3%; p<0.01) and were present most frequently in the temporal sector of both groups. Areas under the receiver operating characteristic curves and sensitivity values at 95% specificity indicated that PRL adjustment did not improve diagnostic accuracy of MRW, globally or temporally. Furthermore, adjusting MRW for PRL did not improve its correlation with RNFL thickness in either group. CONCLUSION: While layers besides the RNFL are sometimes included in OCT measurements of MRW, subtracting these layers does not impact clinical utility.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Torres LA, Jarrar F, Sharpe GP, et al. Clinical relevance of protruded retinal layers in minimum rim width measurement of the optic nerve head. Br J Ophthalmol. 2018. PMID: 30472658. doi:10.1136/bjophthalmol-2018-313070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。