文献速递青光眼神经眼科

注视眼选择与青光眼功能及结构不对称性的关系

The Relationship Between the Sighting Eye and Functional and Structural Asymmetries in Glaucoma.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

结果显示注视眼多对应视野较好眼,且组1较差眼MD更低、双眼MD差值更大,非注视的较差眼上下方视野阈值更差,但相应RNFLT无显著组间差异。

要点

  • 双眼开角型青光眼患者中注视眼多对应视野较好眼(P < 0.001)。
  • 注视眼对应较好眼者,其较差眼MD更低且双眼MD差值更大。
  • 非注视的较差眼上下方视野阈值更差,但对应RNFLT组间无显著差异。

核心结论

  • 注视眼选择与青光眼双眼间功能不对称性相关,功能恶化在非注视的较差眼中更明显。

主要发现

  • 注视眼多对应视野较好眼(P < 0.001)。
  • 组1较差眼MD显著低于组2(P = 0.008),且双眼MD差值显著更大(P < 0.001)。
  • 组1非注视较差眼的上方和下方视野阈值较组2注视的较差眼更差(P = 0.009和0.003),而对应RNFLT组间无显著差异。
  • 多元线性回归显示注视眼选择(P = 0.047)、较高垂直杯盘比(P = 0.042)、较大年龄(P = 0.044)、较薄平均RNFLT(P = 0.007)及较差眼平均GC-IPL厚度(P < 0.001)与较差眼MD显著相关。

临床怎么用

  • 在双眼开角型青光眼评估中可关注注视眼选择,非注视眼若为较差眼可能提示更明显的功能恶化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine the relationship between the sighting eye choice and functional and structural asymmetries in open-angle glaucoma (OAG). METHODS: Two hundred patients with bilateral OAG underwent dominant eye testing using a hole-in-a-card test. The paired eyes were divided into worse and better eyes according to the mean deviation (MD) of visual field (VF) results. Based on the results, patients whose sighting eyes corresponded to eyes with a better VF were designated as group 1, and those whose sighting eyes corresponded to eyes with a worse VF as group 2. RESULTS: The sighting eye corresponded predominantly to eyes with better VFs (P < 0.001). The MD of the worse eye was significantly lower (P = 0.008), and the intereye difference in MD was significantly larger in group 1 than in group 2 (P < 0.001). In a comparison of regional VF threshold values and corresponding retinal nerve fiber layer thickness (RNFLT), the superior and inferior VF threshold values were consistently more deteriorated in the nonsighting worse eyes in group 1 (P = 0.009 and 0.003), compared with the sighting worse eyes in group 2, whereas the corresponding RNFLT was not significantly different between the groups. Multiple linear regression analysis showed that the sighting eye choice (P = 0.047), higher vertical cup-to disc ratio (P = 0.042), older age (P = 0.044), thinner average RNFLT (P = 0.007), and average ganglion cell-inner plexiform layer thickness of worse eyes (P < 0.001) were significantly associated with the MD of the worse eyes. CONCLUSIONS: The sighting eye choice was associated with functional asymmetry between eyes with glaucoma. The functional deterioration was evident in nonsighting eyes with worse VFs.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Choi JA, Jung IY, Jee D, et al. The Relationship Between the Sighting Eye and Functional and Structural Asymmetries in Glaucoma. Invest Ophthalmol Vis Sci. 2018. PMID: 30452598. doi:10.1167/iovs.18-24083

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。