早期原发性开角型青光眼的黄斑血管密度与厚度
一项横断面研究比较了健康眼、前视野期和早期原发性开角型青光眼(POAG)眼的黄斑区神经节细胞复合体(GCC)厚度与黄斑血管密度。结果显示,前视野期和早期POAG眼两者均显著降低;早期POAG眼GCC厚度丢失百分比大于血管密度丢失,但两者诊断准确性相似。
要点
- 前视野期和早期POAG眼黄斑GCC厚度与血管密度均显著低于健康眼。
- 早期POAG眼GCC厚度丢失百分比大于血管密度丢失,前视野期两者丢失相似。
- OCT-A与OCT检测早期青光眼的诊断准确性相似。
核心结论
- 前视野期和早期POAG眼均可检测到GCC变薄和黄斑血管密度丢失。
- 早期视野期POAG眼GCC丢失大于黄斑血管密度丢失。
- OCT-A与OCT测量检测早期青光眼的效率相似。
研究设计与样本
- 同时评估OCT-A测量的浅层黄斑血管密度和OCT测量的GCC厚度。
- 比较GCC厚度和黄斑血管密度相对于正常值的丢失百分比,并用ROC曲线下面积描述诊断效用。
主要发现
- 前视野期和早期POAG眼的GCC厚度和血管密度均显著低于健康眼。
- 与前线视野期POAG组相比,早期POAG组GCC厚度丢失百分比更大(全图像4.72% vs 9.86%;所有P < .01),但血管密度丢失百分比相似(全图像4.97% vs 6.93%;所有P > .05)。
- 在前视野期POAG中,GCC厚度和血管密度丢失百分比相似(所有P > .1);在早期POAG中,GCC厚度丢失百分比大于血管密度丢失(所有P ≤ .001)。
- 区分前视野期或早期青光眼眼与健康眼时,GCC厚度和黄斑血管密度的诊断准确性相似(所有P > .05)。
临床怎么用
- 在前视野期和早期POAG中,可同时关注GCC厚度和黄斑血管密度改变。
- 早期POAG中GCC厚度丢失可能较血管密度丢失更明显,但两者诊断早期青光眼效率相似。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To characterize and compare the ganglion cell complex (GCC) thickness and macula vessel density in preperimetric and early primary open-angle glaucoma (POAG) eyes. DESIGN: Cross-sectional study. METHODS: Fifty-seven healthy, 68 preperimetric, and 162 early POAG eyes enrolled in the Diagnostic Innovations in Glaucoma Study. Optical coherence tomography angiography (OCT-A)-based superficial macula vessel density and OCT-based GCC thickness were evaluated simultaneously. Percent loss from normal of GCC thickness and macula vessel density was compared. Area under the receiver operating characteristic curve was used to describe the diagnostic utility. RESULTS: Both GCC thickness and vessel density were significantly lower in preperimetric and early POAG eyes compared to healthy eyes. Compared to the preperimetric POAG group, the early POAG group showed larger GCC thickness percent loss (whole image 4.72% vs 9.86%; all P < .01) but similar vessel density percent loss (whole image 4.97% vs 6.93%; all P > .05). In preperimetric POAG, GCC thickness and vessel density percent losses were similar (all P > .1). In contrast, in early POAG, GCC thickness percent loss was larger than that of vessel density (all P ≤ .001). To discriminate preperimetric or early glaucoma eyes from healthy eyes, GCC thickness and macula vessel density showed similar diagnostic accuracy (all P > .05). CONCLUSIONS: Both GCC thinning and macula vessel density dropout were detectable in preperimetric and early POAG eyes. GCC loss was greater than macula vessel density loss in early perimetric POAG. However, OCT-A and OCT measurements showed similar efficiency to detect early glaucoma.
引用
- Hou H, Moghimi S, Zangwill LM, et al. Macula Vessel Density and Thickness in Early Primary Open-Angle Glaucoma. Am J Ophthalmol. 2018. PMID: 30496723. doi:10.1016/j.ajo.2018.11.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。