文献速递眼底病与葡萄膜炎

内界膜翻转瓣技术对高度近视黄斑裂孔手术黄斑微结构与视力的影响

Foveal microstructure and visual outcomes of myopic macular hole surgery with or without the inverted internal limiting membrane flap technique.
PubMed 文献 · Br J Ophthalmol · 2018-11-23

本研究比较玻璃体切除联合气体填充术中采用内界膜翻转瓣技术(19眼)与内界膜剥除技术(21眼)治疗高度近视黄斑裂孔的效果。结果显示翻转瓣组黄斑裂孔闭合率(100%)显著高于剥除组(66.7%,p=0.009),且翻转瓣组OCT检测到外界膜、椭圆体带及胶质增生的比例更高,术后最佳矫正视力更好。

要点

  • 内界膜翻转瓣技术黄斑裂孔闭合率(100%)显著高于内界膜剥除技术(66.7%,p=0.009)。
  • 两组伴有黄斑裂孔视网膜脱离的眼均实现视网膜复位。
  • 翻转瓣组外界膜、椭圆体带及胶质增生检出率更高,术后视力更佳。

核心结论

  • 内界膜翻转瓣技术在黄斑裂孔闭合率、黄斑微结构恢复及术后最佳矫正视力方面均优于内界膜剥除技术。

研究设计与样本

  • 回顾性比较研究,纳入高度近视黄斑裂孔伴或不伴视网膜脱离患者,翻转瓣组19眼,剥除组21眼,均行玻璃体切除联合气体填充术。

主要发现

  • 翻转瓣组黄斑裂孔解剖闭合率为100%,剥除组为66.7%,差异有统计学意义(p=0.009)。
  • 两组伴有黄斑裂孔视网膜脱离的眼均成功实现视网膜复位。
  • OCT检测显示翻转瓣组外界膜和椭圆体带(p=0.020)及胶质增生(p=0.049)在黄斑区的检出率显著高于剥除组。
  • 术后存在外界膜、椭圆体带(p=0.031)及胶质增生(p=0.008)的眼最佳矫正视力显著更好,而无高反射灶的眼最佳矫正视力显著更好(p=0.001)。

临床怎么用

  • 对高度近视黄斑裂孔患者,可优先考虑内界膜翻转瓣技术以提高裂孔闭合率并促进黄斑微结构恢复。
  • 术后OCT评估外界膜、椭圆体带及胶质增生等微结构改变有助于预判视力预后。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was to determine the effect of the inverted internal limiting membrane (ILM) flap technique on the macular hole (MH) closure and foveal microstructure recovery of patients with highly myopic MH. METHODS: Pars plana vitrectomy and gas tamponade with the inverted ILM flap technique (19 eyes) or with the ILM peeling technique (21 eyes) were performed in patients with highly myopic MH with or without retinal detachment. The rate of MH closure and retinal reattachment, the reconstructive anatomical change of the foveal microstructure and the best-corrected visual acuities (BCVA) of the two groups were compared. RESULTS: The anatomic closure rate was statistically significantly higher in the inverted group (100%) than in the peeling group (66.7%; p=0.009). All eyes with MH retinal detachment had successful retinal reattachment in these two groups. However, the rate of the external limiting membrane (ELM) and ellipsoid zone (EZ) (p=0.020), as well as gliosis (p=0.049) in macular area, detected by OCT, was significantly greater in the inverted group than in the peeling group. The postoperative BCVA was significantly better in the eyes with ELM, EZ (p=0.031) and gliosis (p=0.008), but without hyperreflective foci (p=0.001). CONCLUSIONS: These findings demonstrate that the inverted ILM flap technique has better efficacy than the ILM peeling technique for patients with myopic MH in closure rate, foveal microstructure and postoperative BCVA.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Hu XT, Pan QT, Zheng JW, et al. Foveal microstructure and visual outcomes of myopic macular hole surgery with or without the inverted internal limiting membrane flap technique. Br J Ophthalmol. 2018. PMID: 30470714. doi:10.1136/bjophthalmol-2018-313311

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。