文献速递小儿眼科与斜弱视

新型双眼分视视动性眼震范式客观量化单眼弱视的双眼间抑制

A Novel Dichoptic Optokinetic Nystagmus Paradigm to Quantify Interocular Suppression in Monocular Amblyopia.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

研究开发了一种双眼分视视动性眼震(OKN)范式,通过向8例单眼屈光参差性弱视者和8例正常者呈现不同对比度的向心移动光栅,用眼动仪记录OKN。结果发现弱视者主导眼OKN追踪时间超过弱视眼,OKN方向比率可由双眼间对比度比率的幂函数拟合,且平衡OKN所需有效对比度比率与弱视眼视力显著正相关(Spearman相关系数0.9698)。该范式无需患者主观报告,可作为客观量化双眼间抑制的可靠指标。

要点

  • 双眼分视向心移动光栅诱发的OKN可客观量化双眼间抑制。
  • 弱视者主导眼OKN追踪时间超过弱视眼,增加一眼对比度可提高其OKN优势。
  • 平衡OKN的有效对比度比率与弱视眼视力显著正相关(Spearman相关系数0.9698)。

核心结论

  • 双眼分视向心移动光栅诱发的OKN可作为客观量化双眼间抑制的可靠指标。

研究设计与样本

  • 研究纳入8例单眼屈光参差性弱视者和8例正常者,向其双眼分视呈现不同对比度比率的恒速向心移动光栅,用EyeLink眼动仪记录并分析OKN。

主要发现

  • 正常者双眼接受相同对比度光栅时,相反方向的OKN追踪时间大致平衡。
  • 弱视者主导眼的OKN追踪时间超过弱视眼。
  • 增加一眼光栅对比度可增加该眼的OKN优势。
  • OKN方向比率(y)可由双眼间对比度比率(x)的幂函数拟合:y = axb。
  • 弱视者中平衡OKN所需有效对比度比率(xb)与弱视眼视力显著正相关(Spearman相关系数0.9698)。

临床怎么用

  • 该范式无需患者主观报告,可作为弱视机制研究和临床实践中量化双眼间抑制的替代指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To develop a novel dichoptic optokinetic nystagmus (OKN) paradigm and investigate its effectiveness in objectively quantifying the interocular suppression in subjects with monocular amblyopia. METHODS: Centripetal moving gratings with different contrast ratios and constant velocity were dichoptically presented to eight monocular anisometropic amblyopes and eight normal subjects. We analyzed the OKN records with an eye tracker (EyeLink; SR-Research, Ontario, Canada) to obtain the relationship between ocular-dominance of OKN and the interocular contrast ratio by fitting power curves, and examined the correlation between the effective contrast ratio for a balanced OKN and the visual acuity of the amblyopic eye in amblyopes. RESULTS: In normal subjects, the OKN pursuit times were roughly balanced for opposite directions when stimulated with centripetal gratings of same contrast; however, in amblyopes, the OKN pursuit times of the dominant eye exceeded that of the amblyopic eye. Increasing the contrast of one eye's grating led to an increase in its OKN dominance. The OKN directional ratio (y) could be well fitted by a power function of the interocular contrast ratio (x): y = axb. Moreover, in amblyopes, the effective contrast ratio (xb) for a balanced OKN correlated significantly positively with the visual acuity of the amblyopic eye (Spearman's correlation coefficient, 0.9698). CONCLUSIONS: The OKN induced by dichoptic gratings moving centripetally could be used as a reliable measure to objectively quantify the interocular suppression. This paradigm, avoiding the need for subjective report from patients, offers a promising alternative index for research on the mechanisms of amblyopia and in clinical practice.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Wen W, Wu S, Wang S, et al. A Novel Dichoptic Optokinetic Nystagmus Paradigm to Quantify Interocular Suppression in Monocular Amblyopia. Invest Ophthalmol Vis Sci. 2018. PMID: 30304459. doi:10.1167/iovs.17-23661

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。