PLGA合成膜替代羊膜用于角膜再生的兔眼局部与全身毒性评估
本研究在兔眼植入直径2 cm、厚50 µm的PLGA 50:50膜(含或不含微制造口袋),以纤维蛋白胶、绷带接触镜和单针缝合固定,对照仅做相同处理而不放膜,观察29天。结果显示膜在29天内完全降解,未引起显著局部或全身毒性,眼压正常、视网膜状态无改变,所有动物眼表最终清晰完整。
要点
- PLGA 50:50膜植入兔角膜后29天内完全降解,未诱导显著局部或全身毒性。
- 含或不含微制造口袋的膜均不影响动物福利,眼压正常且视网膜状态无改变。
- 少数对照与PLGA处理动物出现结膜充血和角膜血管化,29天时所有眼表清晰完整。
核心结论
- 50:50 PLGA膜可安全应用于兔角膜,不诱导局部或全身毒性,并在29天内完全降解。
研究设计与样本
- 兔眼实验:将直径2 cm、厚50 µm的PLGA 50:50膜置于一眼,用纤维蛋白胶、绷带接触镜和单针缝合固定,对照做相同处理但不放膜。
- 评估普通膜与微制造电纺膜(含大致模拟天然角膜缘微环境的微口袋),观察期29天,进行大体与组织病理学观察及详细眼科检查。
主要发现
- 含或不含微制造口袋的膜均未对动物福利产生不良影响。
- 膜在29天时完全降解。
- 膜未诱导任何显著局部或全身毒性。
- 少数对照和PLGA处理动物出现结膜充血和角膜血管化。
- 眼压正常,视网膜状态无改变;29天结束时所有动物眼表清晰完整。
临床怎么用
- 为PLGA 50:50膜作为人供体羊膜合成替代物用于角膜缘干细胞缺乏治疗提供了兔眼安全性证据。
- 提示该膜在29天观察期内可完全降解且无显著局部或全身毒性,支持进一步临床转化研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: The aim of this study was to assess the local and systemic response to poly-lactic co-glycolic acid (PLGA) 50:50 membranes, developed as synthetic biodegradable alternatives to the use of human donor amniotic membrane in the treatment of limbal stem cell deficiency. METHODS: PLGA membranes of 2 cm diameter and 50 µm thickness were placed on one eye of rabbits and secured in place using fibrin glue and a bandage contact lens, suturing the eye close with a single stitch. Control animals were treated identically, with the absence of the membranes. Plain and microfabricated electrospun membranes (containing micropockets which roughly emulate the native limbal niche) were examined over 29 days. All animals were subjected to a detailed gross and histopathological observation as well as a detailed examination of the eye. RESULTS: Application of the membranes both with and without microfabricated pockets did not adversely affect animal welfare. There was complete degradation of the membranes by day 29. The membranes did not induce any significant local or systemic toxicity. Conjunctival congestion and corneal vascularisation were noted in a few control and PLGA-treated animals. Intraocular pressure was normal and the retinal status was unaltered. The ocular surface was clear and intact in all animals by the end of 29 days. CONCLUSION: Membranes of 50:50 PLGA can be safely applied to rabbit corneas without inducing any local or systemic toxicity and these break down completely within 29 days.
引用
- Ramachandran C, Sangwan VS, Ortega I, et al. Synthetic biodegradable alternatives to the use of the amniotic membrane for corneal regeneration: assessment of local and systemic toxicity in rabbits. Br J Ophthalmol. 2018. PMID: 30337329. doi:10.1136/bjophthalmol-2018-312055
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。