新型SITA视野阈值测试算法:构建与多中心临床研究
本研究描述了一种节省时间的阈值视野测试策略——瑞典交互式阈值算法(SITA)Faster,旨在替代SITA Fast,并报告其多中心临床评估。五中心对126例青光眼及可疑青光眼患者的一只眼进行测试,比较SITA Faster、SITA Fast和SITA Standard。结果显示SITA Faster显著缩短测试时间,与SITA Fast结果几乎相同,与SITA Standard存在微小差异。
要点
- SITA Faster平均测试时间171.9秒,较SITA Fast缩短30.4%,较SITA Standard缩短53.5%。
- SITA Faster与SITA Fast的视野指数(VFI)平均差异为0%,结果几乎一致。
- SITA Standard的VFI较SITA Faster低1.2%,且显著测试点略多,与既往SITA Fast vs SITA Standard差异特征相似。
核心结论
- SITA Faster显著节省测试时间,与SITA Fast结果几乎相同,与SITA Standard存在微小差异。
研究设计与样本
- 五中心对126例青光眼及可疑青光眼患者的一只眼,在两次访视中分别进行SITA Faster、SITA Fast和SITA Standard测试。
主要发现
- 平均(标准差)测试时间:SITA Faster 171.9(45.3)秒,SITA Fast 247.0(56.7)秒,SITA Standard 369.5(64.5)秒(P < .001)。
- SITA Faster测试时间平均较SITA Fast缩短30.4%,较SITA Standard缩短53.5%。
- 平均偏差在三种测试间相似;SITA Fast与SITA Faster的VFI平均差异0%。
- SITA Standard的VFI较SITA Fast低1.2%(P = .007),较SITA Faster低1.2%(P = .002)。
- SITA Standard的显著测试点略多于SITA Fast和SITA Faster;三种测试在整个阈值范围内具有相似的测试-重测变异性。
临床怎么用
- 在需要快速视野评估的青光眼及可疑青光眼患者中,可考虑使用SITA Faster以显著缩短测试时间。
- SITA Faster与SITA Fast结果几乎一致,可作为SITA Fast的替代策略。
- 需注意SITA Faster与SITA Standard之间存在微小差异,解读结果时应考虑算法差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To describe a new time-saving threshold visual field-testing strategy-Swedish Interactive Thresholding Algorithm (SITA) Faster, which is intended to replace SITA Fast-and to report on a clinical evaluation of this new strategy. DESIGN: Description and validity analysis for modifications applied to SITA Fast. METHODS: Five centers tested 1 eye of each of 126 glaucoma and glaucoma suspect patients with SITA Faster, SITA Fast, and SITA Standard at each of 2 visits. Outcomes included test time, mean deviation, and the visual field index (VFI), significant test points in probability maps, and intertest threshold variability. RESULTS: Mean (standard deviation) test times were 171.9 (45.3) seconds for SITA Faster, 247.0 (56.7) for SITA Fast, and 369.5 (64.5) for SITA Standard (P < .001). SITA Faster test times averaged 30.4 % shorter than SITA Fast and 53.5 % shorter than SITA Standard. Mean deviation was similar among all 3 tests.VFI did not differ between SITA Fast and SITA Faster tests, mean difference 0%, but VFI values were 1.2% lower with SITA Standard compared to both SITA Fast (P = .007) and SITA Faster (P = .002). A similar trend was seen with a slightly higher number of significant test points with SITA Standard than with SITA Fast and SITA Faster. All 3 tests had similar test-retest variability over the entire range of threshold values. CONCLUSIONS: SITA Faster saved considerable test time. SITA Faster and SITA Fast gave almost identical results. There were small differences between SITA Faster and SITA Standard, of the same character as previously shown for SITA Fast vs SITA Standard.
引用
- Heijl A, Patella VM, Chong LX, et al. A New SITA Perimetric Threshold Testing Algorithm: Construction and a Multicenter Clinical Study. Am J Ophthalmol. 2018. PMID: 30336129. doi:10.1016/j.ajo.2018.10.010