常染色体隐性Bestrophinopathy中视锥光感受器镶嵌的变化
本研究对5例常染色体隐性Bestrophinopathy患者的双眼进行频域OCT和自适应光学眼底成像,测量黄斑区视锥密度。结果显示黄斑区视锥密度显著降低,中心凹处低于正常三分之一,尽管部分患者视力较好;自适应光学成像可监测视锥变化。
要点
- 常染色体隐性Bestrophinopathy患者黄斑区存在显著视锥丢失。
- 中心凹视锥密度可低于正常三分之一(范围11,600-30,400 cells/mm)。
- 自适应光学成像可评估视锥镶嵌变化并监测疾病状态。
核心结论
- 常染色体隐性Bestrophinopathy患者黄斑区视锥光感受器显著丢失,即使视力相对较好。
- 自适应光学眼底成像有助于准确评估疾病状态和未来治疗干预指征。
研究设计与样本
- 对5例常染色体隐性Bestrophinopathy患者的双眼进行频域OCT和自适应光学眼底成像。
- 在距中心凹500 μm鼻侧至颞侧范围内,每隔100 μm测量视锥光感受器密度。
主要发现
- 患者中位年龄30岁(范围23-45岁),最佳矫正视力范围20/20至20/80。
- 4例视力相对较好的患者自适应光学图像显示视锥密度降低,对应OCT上光感受器层损害。
- 中心凹视锥密度低于正常三分之一(范围11,600-30,400 cells/mm)。
- 浆液性视网膜脱离和视网膜水肿病灶上可见视锥镶嵌,但部分呈低反射。
临床怎么用
- 对常染色体隐性Bestrophinopathy患者可考虑自适应光学眼底成像监测视锥变化。
- 视锥密度评估可能辅助判断疾病状态及未来治疗干预指征。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the morphological changes of cone photoreceptors in eyes with autosomal recessive bestrophinopathy. METHODS: Both eyes of five patients with autosomal recessive bestrophinopathyunderwent spectral domain optical coherence tomography and adaptive optics fundus imaging. The cone photoreceptor densities were measured at intervals of 100 μm between 500 μm nasal and temporal eccentricities from the foveal center. RESULTS: The median age of the patients was 30 years (range, 23-45 years), and the best-corrected visual acuity ranged from 20/20 to 20/80. Adaptive optics fundus images showed reduced cone photoreceptor densities corresponding to the damages of the photoreceptor layer in the spectral domain optical coherence tomography images in four patients with relatively good best-corrected visual acuity. The cone photoreceptor densities at the center of the fovea were less than one-third of the normal cone densities (range 11,600-30,400 cells/mm). Cone photoreceptor mosaics were visible over the lesions with serous retinal detachment and retinal edema, although they were partially hyporeflective. CONCLUSION: There is a significant cone photoreceptor loss in the macular region of patients with autosomal recessive bestrophinopathy, although they had relatively good visual acuity. Monitoring cone photoreceptors by adaptive optics fundus imaging should provide accurate assessments of the disease status and indications for future therapeutic interventions.
引用
- Nakanishi A, Ueno S, Hayashi T, et al. CHANGES OF CONE PHOTORECEPTOR MOSAIC IN AUTOSOMAL RECESSIVE BESTROPHINOPATHY. Retina. 2020. PMID: 30308565. doi:10.1097/IAE.0000000000002363
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。