文献速递角膜与眼表疾病

角膜断层扫描与生物力学联合提升扩张检测准确性

Enhanced Ectasia Detection Using Corneal Tomography and Biomechanics.
PubMed 文献 · Am J Ophthalmol · 2018-09-08

这项回顾性病例对照研究在独立人群中验证了断层扫描与生物力学指数(TBI)检测角膜扩张的准确性。TBI区分正常与扩张角膜的AUC为0.988,高于其他测试参数(DeLong检验P<.001)。在 topography 正常的极不对称扩张对侧眼中,优化cut-off值0.295时灵敏度89.5%、特异度91.0%。

要点

  • TBI区分正常与扩张角膜的AUC为0.988,显著高于其他参数。
  • 全病例中TBI cut-off值0.335时灵敏度94.4%、特异度94.9%。
  • VAE-NT组优化cut-off值0.295时灵敏度89.5%、特异度91.0%。

核心结论

  • TBI在区分正常与扩张角膜方面比所有测试参数更准确,可能体现扩张易感性并区分顿挫型与真单侧病例。

研究设计与样本

  • 回顾性病例对照研究,纳入正常组312眼、圆锥角膜组118眼、VAE-E组57眼及VAE-NT组57眼,各随机选1眼。

主要发现

  • TBI的AUC在统计学上高于所有其他测试参数(DeLong检验,P<.001)。
  • 全病例中TBI cut-off值0.335时灵敏度94.4%、特异度94.9%(AUC=0.988;95%CI 0.982-0.995)。
  • VAE-NT组优化TBI cut-off值0.295时灵敏度89.5%、特异度91.0%(AUC=0.960;95%CI 0.937-0.983)。

关键数值与推荐

  • 全病例TBI cut-off值0.335:灵敏度94.4%,特异度94.9%,AUC=0.988(95%CI 0.982-0.995)。
  • VAE-NT组优化TBI cut-off值0.295:灵敏度89.5%,特异度91.0%,AUC=0.960(95%CI 0.937-0.983)。

临床怎么用

  • 临床可结合角膜断层扫描与生物力学TBI指数辅助识别角膜扩张,尤其在 topography 正常但怀疑扩张的病例中。

局限性

  • 本研究为回顾性病例对照设计,结果需在前瞻性人群中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To test the accuracy of the Tomographic and Biomechanical Index (TBI) for ectasia detection in an independent population from the original study. DESIGN: Retrospective case-control study. METHODS: Subjects: Patients were grouped according to clinical diagnosis including corneal topography (front-surface curvature): Normal group, including 1 eye randomly selected from 312 patients with normal corneas; Keratoconus group, including 1 eye randomly selected from 118 patients with keratoconus; a nonoperated ectatic eye from 57 patients with very asymmetric ectasia (57 eyes, VAE-E group), and the nonoperated fellow eye with normal topography (57 eyes, VAE-NT group). MAIN OUTCOME MEASURES: The ability of TBI to distinguish normal and ectatic corneas; and comparison with other indexes, including the Belin/Ambrósio Deviation Index (BAD-DI) and the Corvis Biomechanical Index (CBI), considering the areas under receiver operating characteristic curves (AUCs). RESULTS: The AUC of the TBI was statistically higher than all other tested parameters (DeLong, P < .001). Considering all cases, the cut-off value of 0.335 for the TBI provided a sensitivity of 94.4% and a specificity of 94.9% (AUC = 0.988; 95% confidence interval [CI] 0.982-0.995). Considering the VAE-NT group, optimized TBI cut-off value of 0.295 provided a sensitivity of 89.5% and a specificity of 91.0% (AUC = 0.960; 95% CI 0.937-0.983). CONCLUSION: The TBI was more accurate than all parameters tested for differentiating normal from ectatic corneas. The TBI may epitomize ectasia susceptibility and distinguish cases with fruste disease from true unilateral cases among the eyes with normal-topography VAE.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Ferreira-Mendes J, Lopes BT, Faria-Correia F, et al. Enhanced Ectasia Detection Using Corneal Tomography and Biomechanics. Am J Ophthalmol. 2018. PMID: 30201341. doi:10.1016/j.ajo.2018.08.054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。