晶状体赤道面作为预测术后人工晶状体位置的新参数
该干预性病例系列纳入104眼行超声乳化联合人工晶状体(IOL)植入,术前用飞秒激光白内障手术系统测量晶状体赤道面(LEP),术后用Scheimpflug相机测前房深度(ACD)。结果显示LEP与术后ACD显著正相关,基于LEP的射线追踪法预测中位绝对误差小于Haigis公式。
要点
- 术前LEP与术后ACD显著正相关,三组回归分析均显示术后ACD与LEP显著相关。
- 基于LEP的射线追踪法预测中位绝对误差在三组均小于Haigis公式。
- LEP是术前晶状体几何参数,有望成为改善白内障手术屈光结果的新指标。
核心结论
- LEP是术前晶状体几何测量中有前景的参数,可能有助于改善白内障手术的屈光结果。
研究设计与样本
- 比较性干预病例系列,纳入104眼行超声乳化联合IOL植入,分三组分别植入ZCB00、EC-1PAL和CT Asphina。
- 术前用飞秒激光白内障手术系统获取包括LEP在内的晶状体几何参数,术后用Scheimpflug相机测量ACD。
主要发现
- 三组术前ACD分别为3.27±0.39 mm(R=0.428)、3.30±0.47 mm(R=0.591)、3.49±0.39 mm(R=0.373),均与术后ACD显著正相关。
- 三组术前LEP分别为4.81±0.29 mm(R=0.570)、4.84±0.27 mm(R=0.634)、4.97±0.23 mm(R=0.565),均与术后ACD显著正相关。
- 三组术后ACD分别为5.24±0.40 mm、5.02±0.31 mm、5.19±0.26 mm。
- 逐步回归分析显示三组术后ACD均与LEP显著相关。
- 基于LEP的射线追踪法预测中位绝对误差在三组均小于Haigis公式。
临床怎么用
- 术前可考虑测量LEP作为预测术后IOL位置的参考参数。
- 在个体化眼模型中纳入LEP的射线追踪法可能优于Haigis公式。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess whether preoperative crystalline lens equatorial plane (LEP) reliably predicts the postoperative position of the intraocular lens (IOL). DESIGN: Comparative, interventional case series. METHODS: Phacoemulsification and IOL implantation (Group I, ZCB00; Group II, EC-1PAL; and Group III, CT Asphina) were performed for 104 eyes. Lens geometry parameters, including LEP, were obtained from a femtosecond laser cataract surgery system prior to surgery. LEP was defined as the distance from the front surface of the cornea to the equatorial plane of the crystalline lens. Postoperative anterior chamber depth (ACD) was measured using a Scheimpflug camera. Median absolute error was calculated using an optical ray-tracing method that incorporated LEP into an individualized eye model, and the results were compared with those from the Haigis formula. RESULTS: Preoperative ACD (3.27 ± 0.39 mm [R = 0.428], 3.30 ± 0.47 mm [R = 0.591], and 3.49 ± 0.39 mm [R = 0.373] in Groups I, II, and III, respectively) and LEP (4.81 ± 0.29 mm [R = 0.570], 4.84 ± 0.27 mm [R = 0.634], and 4.97 ± 0.23 mm [R = 0.565] in Groups I, II, and III, respectively) were found to have significant positive correlations with postoperative ACD (5.24 ± 0.40 mm, 5.02 ± 0.31 mm, and 5.19 ± 0.26 mm in Groups I, II, and III, respectively). Stepwise regression analysis showed that postoperative ACD was significantly correlated with LEP in all groups. Median absolute errors predicted by the ray-tracing method using LEP were smaller than those from the Haigis formula in all groups. CONCLUSIONS: LEP is a promising measure from preoperative crystalline lens geometry and could serve as a new parameter to improve refractive outcomes in cataract surgery.