非人灵长类遥测中眼压、眼压瞬态冲量、眼灌注压与平均动脉压的关系
该研究用植入式遥测系统在4只雄性恒河猴的7只眼连续记录双眼眼压和动脉血压,分析眼压瞬态冲量与眼灌注压等关系。结果显示眼压瞬态冲量与眼灌注压在所有眼中呈显著正相关,主要由清醒时段数据驱动;眼压与平均动脉压等无显著关系。
要点
- 眼压瞬态冲量与眼灌注压在所有眼中呈显著正相关,主要由清醒时段驱动。
- 眼压与平均动脉压、眼压瞬态冲量与平均动脉压均无显著关系。
- 眼压基线冲量与眼压瞬态冲量之间无显著关系。
核心结论
- 眼压瞬态波动的频率和/或幅度(眼压瞬态冲量)与眼灌注压之间存在显著正相关。
研究设计与样本
- 研究使用经过验证的植入式遥测系统,在4只4至5岁雄性恒河猴的7只眼中以500 Hz无线记录双眼眼压和动脉血压。
- 眼压、平均动脉压、眼灌注压、眼压瞬态冲量和眼压基线冲量按每只非人灵长类20天内的1小时时段取平均值。
- 每个24小时周期使用多变量线性回归或Spearman相关系数分析变量间关系。
主要发现
- 在二十个24小时周期中,眼压瞬态冲量与眼灌注压在所有眼中均呈显著正相关,且主要由清醒时段数据驱动。
- 眼压与平均动脉压、眼压瞬态冲量与平均动脉压、眼压基线冲量与眼压瞬态冲量之间均无显著关系。
关键数值与推荐
- 眼压瞬态冲量定义为仅由持续时间小于0.5秒的瞬态眼压波动所致的总眼压部分。
- 眼压基线冲量定义为眼压-时间曲线下剩余的面积。
- 眼灌注压定义为动脉血压减眼压(连续计算)。
- 平均动脉压为连续血压曲线的每小时平均值。
临床怎么用
- 提示眼压瞬态波动与眼灌注压相关,临床解读眼压波动时需考虑灌注压状态。
- 清醒时段活动可能同时增加眼灌注压和瞬态眼压波动来源(如眨眼和扫视)。
局限性
- 研究样本为非人灵长类(4只雄性恒河猴的7只眼),结果外推至人类需谨慎。
- 原文未报告具体效应量、置信区间或P值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To characterize relationships between intraocular pressure (IOP), mean arterial pressure (MAP), ocular perfusion pressure (OPP), IOP transient impulse, and IOP baseline impulse using continuous telemetry in nonhuman primates. METHODS: We used our validated implantable telemetry system to wirelessly record bilateral IOP and arterial BP at 500 Hz in 7 eyes of 4 male rhesus macaques, aged 4 to 5 years. IOP, MAP, OPP, IOP transient impulse, and IOP baseline impulse were averaged into 1-hour periods over 20 days for each NHP. IOP transient impulse was defined as the portion of total IOP due to transient IOP fluctuations <0.5 seconds duration alone and IOP baseline impulse as the remaining area under the IOP versus time curve. OPP was defined as arterial BP-IOP (calculated continuously), and MAP was the hourly average of the continuous BP curve. Relationships between the variables were analyzed for each 24-hour period using either multivariate linear regression or Spearman Correlation Coefficients as appropriate. RESULTS: Over twenty 24-hour periods, IOP transient impulse and OPP showed significant positive relationship in all eyes, which was driven largely by the data during waking hours. There was no significant relationship between IOP and MAP, IOP transient impulse and MAP, or IOP baseline impulse and IOP transient impulse. CONCLUSIONS: There are significant positive relationships between the frequency and/or size of transient IOP fluctuations (IOP transient impulse) and OPP. A possible explanation of this finding is that higher OPP, as well as a greater number of blinks and saccades (the primary sources of IOP transients), are associated with increased activity.
引用
- Markert JE, Jasien JV, Turner DC, et al. IOP, IOP Transient Impulse, Ocular Perfusion Pressure, and Mean Arterial Pressure Relationships in Nonhuman Primates Instrumented With Telemetry. Invest Ophthalmol Vis Sci. 2018. PMID: 30208417. doi:10.1167/iovs.18-23802
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。