文献速递角膜与眼表疾病白内障与屈光手术

基于人工智能的断层扫描评估增强角膜扩张检测

Enhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence.
PubMed 文献 · Am J Ophthalmol · 2018-08-09

一项多中心病例对照研究利用Pentacam HR参数构建AI模型,以区分稳定LASIK、LASIK后扩张易感及临床圆锥角膜。

要点

  • PRFI对临床扩张(KC+VAE-E)灵敏度100%, cutoff 0.52。
  • 优化cutoff 0.125对VAE-NT灵敏度85.2%,对PLE灵敏度80%,特异性96.6%。

核心结论

  • PRFI可增强角膜扩张的诊断准确性,但评估扩张风险仍需整合角膜生物力学参数及激光视力矫正的角膜影响。

研究设计与样本

  • 多中心病例对照研究,数据来自南美、美国及欧洲5家诊所,使用Pentacam HR参数生成AI模型。

主要发现

  • 随机森林模型(PRFI)对临床扩张(KC+VAE-E)灵敏度100%(cutoff 0.52)。
  • 优化cutoff 0.125对VAE-NT灵敏度85.2%,对PLE灵敏度80%,特异性96.6%。

关键数值与推荐

  • PRFI cutoff 0.52时对临床扩张灵敏度100%。
  • PRFI cutoff 0.216时AUC 0.992,灵敏度94.2%,特异性98.8%。
  • PRFI cutoff 0.125时对VAE-NT灵敏度85.2%,对PLE灵敏度80%,特异性96.6%。

临床怎么用

  • PRFI可作为Pentacam HR参数衍生的AI指标,辅助识别LASIK术前临床扩张及扩张易感眼。
  • 对于地形图正常但对侧眼有扩张的VAE-NT眼,PRFI cutoff 0.125可提供较高灵敏度筛查。

局限性

  • 需进一步整合角膜生物力学参数及激光视力矫正的角膜影响以评估扩张风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To improve the detection of corneal ectasia susceptibility using tomographic data. DESIGN: Multicenter case-control study. METHODS: Data from patients from 5 different clinics from South America, the United States, and Europe were evaluated. Artificial intelligence (AI) models were generated using Pentacam HR (Oculus, Wetzlar, Germany) parameters to discriminate the preoperative data of 3 groups: stable laser-assisted in situ keratomileusis (LASIK) cases (2980 patients with minimum follow-up of 7 years), ectasia susceptibility (71 eyes of 45 patients that developed post-LASIK ectasia [PLE]), and clinical keratoconus (KC; 182 patients). Model accuracy was independently tested in a different set of stable LASIK cases (298 patients with minimum follow-up of 4 years) and in 188 unoperated patients with very asymmetric ectasia (VAE); these patients presented normal topography (VAE-NT) in 1 eye and clinically diagnosed ectasia in the other (VAE-E). Accuracy was evaluated with ROC curves. RESULTS: The random forest (RF) provided highest accuracy among AI models in this sample with 100% sensitivity for clinical ectasia (KC+VAE-E; cutoff 0.52), being named Pentacam Random Forest Index (PRFI). Considering all cases, the PRFI had an area under the curve (AUC) of 0.992 (94.2% sensitivity, 98.8% specificity; cutoff 0.216), being statistically higher than the Belin/Ambrósio deviation (BAD-D; AUC = 0.960, 87.3% sensitivity, 97.5% specificity; P = .006, DeLong's test). The optimized cutoff of 0.125 provided sensitivity of 85.2% for VAE-NT and 80% for PLE, with 96.6% specificity. CONCLUSION: The PRFI enhances ectasia diagnosis. Further integrations with corneal biomechanical parameters and with the corneal impact from laser vision correction are needed for assessing ectasia risk.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Lopes BT, Ramos IC, Salomão MQ, et al. Enhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence. Am J Ophthalmol. 2018. PMID: 30098348. doi:10.1016/j.ajo.2018.08.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。