「Van Herick Plus」:评估周边前房深度与房角的新分级方案
一项横断面研究纳入40岁以上有晶状体眼连续患者,采用短垂直裂隙灯光束在下方角巩膜缘处评估周边前房深度与房角,并以ImageJ软件计算周边前房深度与周边角膜厚度比值(PAC:PCT)及虹膜角膜角(ICA)。临床评估的房角与ASOCT测得的房角参数(TIA、巩膜突角)高度相关,以PAC:PCT<1/4为截断值识别ASOCT窄角(TIA<200)的曲线下面积为0.918,敏感度85.2%、特异度88.2%。
要点
- 短垂直裂隙灯光束在下方房角评估周边前房深度与房角,与ASOCT参数高度相关。
- PAC:PCT<1/4识别ASOCT窄角(TIA<200)的AUC为0.918,敏感度85.2%、特异度88.2%。
- 青光眼专科医师主观分级与ImageJ参数一致性良好(加权kappa=0.74),优于普通眼科医师(0.57)。
核心结论
- 短垂直裂隙灯光束在下方房角评估周边前房深度与房角是一种简便且相对准确的方法。
- 该方法与ASOCT相关性良好,可作为识别可能闭角眼的更可靠筛查工具。
研究设计与样本
- 横断面研究,纳入40岁以上有晶状体眼连续患者。
- 采用短垂直裂隙灯光束(未达瞳孔)在下方角巩膜缘处评估、拍照,并用ImageJ软件计算PAC:PCT比值与ICA。
- 同一子午线下方房角同时行ASOCT记录。
主要发现
- 按PAC:PCT比值将受试者分为四组:I(<1/4)、II(1/4-1/2)、III(>1/2-1)、IV(>1)。
- 临床评估房角与ASOCT的TIA相关(r=0.918;p<0.001),与巩膜突角相关(r=0.903;p<0.001)。
- ICA与ASOCT的TIA平均差异为0.7970,95%一致性界限为-5.7670至7.3610(±1.96 SD)。
- 以PAC:PCT<1/4为截断值识别ASOCT窄角(TIA<200),AUC为0.918,敏感度85.2%,特异度88.2%。
- ImageJ参数与青光眼专科医师主观分级一致性良好(加权kappa=0.74),与普通眼科医师一致性中等(加权kappa=0.57)。
关键数值与推荐
- PAC:PCT比值分组标准:I组<1/4,II组1/4-1/2,III组>1/2-1,IV组>1。
- 识别ASOCT窄角(TIA<200)的截断值:PAC:PCT<1/4,AUC=0.918,敏感度85.2%,特异度88.2%。
- 临床ICA与ASOCT TIA的一致性界限:平均差异0.7970,95%一致性界限-5.7670至7.3610(±1.96 SD)。
临床怎么用
- 可采用短垂直裂隙灯光束在下方房角评估周边前房深度与房角,作为闭角型青光眼筛查的简便方法。
- PAC:PCT<1/4可作为提示房角狭窄、需进一步ASOCT检查的参考截断值。
- 由青光眼专科医师进行主观分级与ImageJ参数一致性更好,普通眼科医师一致性中等。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the accuracy of a new, modified grading scheme involving a short vertical slit beam, at the inferior angle for peripheral anterior chamber depth (PAC) and angle estimation and its correlation with anterior segment optical coherence tomography (ASOCT). METHODS: A cross-sectional study of consecutive phakic patients, above 40 years of age, was performed. Using a short, vertical slit beam not reaching the pupil, the inferior angle at the sclerolimbal junction was evaluated, photographed and assessed by a ratio of peripheral anterior chamber depth to peripheral corneal thickness (PAC:PCT) and iridocorneal angle (ICA) on ImageJ software. The inferior angle at the same meridian was also recorded on ASOCT. RESULTS: Based on the PAC:PCT ratio, the subjects were divided into four groups: I (<1/4), II (1/4-1/2), III (>1/2-1) and IV (>1). The clinically assessed angle by short vertical slit beam correlated well with ASOCT values, trabecular-iris angle (TIA) (r=0.918; p<0.001) and scleral spur angle (r=0.903, p<0.001). The mean difference between ICA and TIA on ASOCT was 0.7970; 95% limits of agreement:-5.7670 to 7.3610 (±1.96 SD). For angles graded narrow on ASOCT (TIA <200), using a cut-off of peripheral PAC:PCT <1/4, the area under the curve was 0.918 with a sensitivity of 85.2% and a specificity of 88.2%. There was good agreement between ImageJ parameters with those assessed subjectively on photograph of the slit beam examination by a glaucoma fellow (weighted kappa=0.74) as compared with a general ophthalmologist, where there was moderate agreement (weighted kappa=0.57). CONCLUSION: A short, vertical slit lamp beam evaluation at the inferior angle is an easy and relatively accurate method for both peripheral anterior chamber depth and angle assessment. It correlated well with ASOCT and can be used as a more reliable screening tool to identify eyes with possibly occludable angles.
引用
- Sihota R, Kamble N, Sharma AK, et al. 'Van Herick Plus': a modified grading scheme for the assessment of peripheral anterior chamber depth and angle. Br J Ophthalmol. 2018. PMID: 30068514. doi:10.1136/bjophthalmol-2018-312132
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。