文献速递青光眼眼底病与葡萄膜炎

高密度与非高密度OCTA视盘周围血管密度测量在正常眼与青光眼中的可重复性与可比性

Repeatability and comparability of peripapillary vessel density measurements of high-density and non-high-density optical coherence tomography angiography scans in normal and glaucoma eyes.
PubMed 文献 · Br J Ophthalmol · 2018-08-17

横断面研究纳入46只正常眼(33名受试者)和89只青光眼(64例患者),同一次会话内完成3次高密度(HD)和1次非HD视盘OCTA扫描。HD扫描的血管密度(VD)显著高于非HD扫描,两者95%一致性界限宽,不能互换使用;HD扫描VD的组内重测可重复性在青光眼中最高达6%。

要点

  • HD扫描测得的视盘周围VD显著高于非HD扫描,平均差异0.7%至2.0%。
  • HD与非HD扫描VD的95%一致性界限宽,二者测量值不能互换使用。
  • HD扫描VD的重测可重复性在正常眼和青光眼中分别约为3.0–4.9%和3.2–6.7%。

核心结论

  • HD扫描的视盘周围VD高于非HD扫描,两者95%一致性界限宽,不能互换使用。
  • HD扫描VD的组内重测可重复性在青光眼中最高达6%。

研究设计与样本

  • 横断面研究,纳入46只正常眼(33名受试者)和89只青光眼(64例患者)。
  • 同一会话内完成3次HD和1次非HD视盘OCTA扫描。
  • 采用Bland-Altman分析评估HD与非HD扫描VD的一致性,采用组内重复性系数(CRw)和变异系数(CVw)评估HD扫描VD的可重复性。

主要发现

  • HD扫描的VD显著高于非HD扫描,平均差异范围为0.7%(颞侧扇区VD)至2.0%(鼻下扇区VD)。
  • 青光眼眼中,全周VD的95%一致性界限为-2.0%至5.0%,颞上VD的95%一致性界限为-4.8%至9.6%。
  • 正常眼中HD扫描VD的CRw为3.0%至4.9%,CVw为2.0%至3.1%。
  • 青光眼眼中HD扫描VD的CRw为3.2%至6.7%,CVw为2.6%至4.8%。

临床怎么用

  • 临床使用OCTA纵向评估青光眼时,应考虑到HD与非HD扫描VD测量值不可互换。
  • HD扫描VD的重测可重复性最高约6%,在解读纵向变化时需考虑该变异范围。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To compare the peripapillary vessel density (VD) measurements of high-density (HD) and non-HD optical coherence tomography angiography (OCTA) scans in normal and glaucoma eyes, and to evaluate the intrasession repeatability of VD measurements of HD scans. METHODS: In a cross-sectional study, 46 normal (33 subjects) and 89 glaucoma (64 patients) eyes underwent 3 HD and 1 non-HD optic nerve head OCTA scans in the same session. Agreement in VD measurements between HD and non-HD scans was assessed using Bland and Altman analysis. Repeatability of the VD measurements of HD scans was assessed using within-subject coefficient of repeatability (CRw) and variation (CVw). RESULTS: The mean difference in the VDs ranged between 0.7% (temporal sector VD) and 2.0% (inferonasal sector VD), with HD scans showing significantly greater VD values than non-HD scans. The 95% limits of agreement (LoA) in glaucoma eyes ranged between -2.0% and 5.0% for whole enface VD and between -4.8% and 9.6% for superotemporal VD. CRw (%) and CVw (%) of VD measurements of HD scans ranged from 3.0 to 4.9 and from 2.0 to 3.1 in normal eyes. The same ranged from 3.2 to 6.7 and from 2.6 to 4.8, respectively, in glaucoma eyes. CONCLUSIONS: VD of HD scans was higher than that of non-HD scans. The wide 95% LoA indicates that the VD measurements of HD and non-HD scans cannot be used interchangeably. Test-retest repeatability of VDs on HD scans was as high as 6%. These results should be considered while using OCTA for longitudinal evaluation of glaucoma.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Venugopal JP, Rao HL, Weinreb RN, et al. Repeatability and comparability of peripapillary vessel density measurements of high-density and non-high-density optical coherence tomography angiography scans in normal and glaucoma eyes. Br J Ophthalmol. 2018. PMID: 30120128. doi:10.1136/bjophthalmol-2018-312401

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。